• 제목/요약/키워드: multiple dampers

검색결과 75건 처리시간 0.024초

Critical earthquake input energy to connected building structures using impulse input

  • Fukumoto, Yoshiyuki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1133-1152
    • /
    • 2015
  • A frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. It is demonstrated that the proposed energy transfer function is very useful for clear understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It can be shown that the area of the energy transfer function for the total system is constant regardless of natural period and damping ratio because the constant Fourier amplitude of the input acceleration, relating directly the area of the energy transfer function to the input energy, indicates the Dirac delta function and only an initial velocity (kinetic energy) is given in this case. Owing to the constant area property of the energy transfer functions, the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically. For the worst case analysis, critical excitation problems with respect to the impulse interval for double impulse (simplification of pulse-type impulsive ground motion) and multiple impulses (simplification of long-duration ground motion) are considered and their solutions are provided.

Dynamic characteristics of multiple inerter-based dampers for suppressing harmonically forced oscillations

  • Chen, Huating;Jia, Shaomin;He, Xuefeng
    • Structural Engineering and Mechanics
    • /
    • 제72권6호
    • /
    • pp.747-762
    • /
    • 2019
  • Based on the ball-screw mechanism, a tuned viscous mass damper (TVMD) has been proposed, which has functions of amplifying physical mass of the system and frequency tuning. Considering the sensitivity of a single TVMD's effectiveness to frequency mistuning like that of the conventional tuned mass damper (TMD) and according to the concept of the conventional multiple tuned mass damper (MTMD), in the present paper, multiple tuned mass viscous dampers (MTVMD) consisting of many tuned mass dampers (TVMD) with a uniform distribution of natural frequencies are considered for attenuating undesirable vibration of a structure. The MTVMD is manufactured by keeping the stiffness and damping constant and varying the mass associated with the lead of the ball-screw type inerter element in the damper. The structure is represented by its mode-generalized system in a specific vibration mode controlled using the mode reduced-order method. Modal properties and fundamental characteristics of the MTVMD-structure system are investigated analytically with the parameters, i.e., the frequency band, the average damping ratio, the tuning frequency ratio, the total number of TVMD and the total mass ratio. It is found that there exists an optimum set of the parameters that makes the frequency response curve of the structure flattened with smaller amplitudes in a wider input frequency range. The effectiveness and robustness of the MTVMD are also discussed in comparison with those of the usual single TVMD (STVMD) and the results shows that the MTVMD is more effective and robust with the same level of total mass.

Estimation of active multiple tuned mass dampers for asymmetric structures

  • Li, Chunxiang;Xiong, Xueyu
    • Structural Engineering and Mechanics
    • /
    • 제29권5호
    • /
    • pp.505-530
    • /
    • 2008
  • This paper proposes the application of active multiple tuned mass dampers (AMTMD) for translational and torsional response control of a simplified two-degree-of-freedom (2DOF) structure, able to represent the dynamic characteristics of general asymmetric structures, under the ground acceleration. This 2DOF structure is a generalized 2DOF system of an asymmetric structure with predominant translational and torsional responses under earthquake excitations using the mode reduced-order method. Depending on the ratio of the torsional to the translational eigenfrequency, i.e. the torsional to translational frequency ratio (TTFR), of asymmetric structures, the following three cases can be distinguished: (1) torsionally flexible structures (TTFR < 1.0), (2) torsionally intermediate stiff structures (TTFR = 1.0), and (3) torsionally stiff structures (TTFR > 1.0). The even distribution of the AMTMD within the whole width and half width of the asymmetric structure, thus leading to three cases of installing the AMTMD (referred to as the AMTMD of case 1, AMTMD of case 2, AMTMD of case 3, respectively), is taken into account. In the present study, the criterion for searching the optimum parameters of the AMTMD is defined as the minimization of the minimum values of the maximum translational and torsional displacement dynamic magnification factors (DMF) of an asymmetric structure with the AMTMD. The criterion used for assessing the effectiveness of the AMTMD is selected as the ratio of the minimization of the minimum values of the maximum translational and torsional displacement DMF of the asymmetric structure with the AMTMD to the maximum translational and torsional displacement DMF of the asymmetric structure without the AMTMD. By resorting to these two criteria, a careful examination of the effects of the normalized eccentricity ratio (NER) on the effectiveness and robustness of the AMTMD are carried out in the mitigation of both the translational and torsional responses of the asymmetric structure. Likewise, the effectiveness of a single ATMD with the optimum positions is presented and compared with that of the AMTMD.

Optimization of multiple tuned mass dampers for large-span roof structures subjected to wind loads

  • Zhou, Xuanyi;Lin, Yongjian;Gu, Ming
    • Wind and Structures
    • /
    • 제20권3호
    • /
    • pp.363-388
    • /
    • 2015
  • For controlling the vibration of specific building structure with large span, a practical method for the design of MTMD was developed according to the characteristics of structures subjected to wind loads. Based on the model of analyzing wind-induced response of large-span structure with MTMD, the optimization method of multiple tuned mass dampers for large-span roof structures subjected to wind loads was established, in which the applicable requirements for strength and fatigue life of TMD spring were considered. According to the method, the controlled modes and placements of TMDs in MTMD were determined through the quantitative analysis on modal contribution to the wind-induced dynamic response of structure. To explore the characteristics of MTMD, the parametric analysis on the effects of mass ratio, damping ratio, central tuning frequency ratio and frequency range of MTMD, was performed in the study. Then the parameters of MTMD were optimized through genetic algorithm and the optimized MTMD showed good dynamic characteristics. The robustness of the optimized MTMD was also investigated.

Optimum tuned mass damper approaches for adjacent structures

  • Nigdeli, Sinan Melih;Bekdas, Gebrail
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1071-1091
    • /
    • 2014
  • Pounding of adjacent structures are always a notable reason for damages after strong ground motions, but it is already unforeseen detail in newly constructed structures. Thus, several approaches have been proposed in order to prevent the pounding of structures. By using optimally tuned mass dampers, it is possible to decrease the displacement vibrations of structures. But in adjacent structures, the response of both structures must be considered in the objective function of optimization process. In this paper, two different designs of Tuned Mass Dampers (TMD) are investigated. The first design covers independent TMDs on both structures. In the second design, adjacent structures are coupled by a TMD on the top of the structures. Optimum TMD parameters are found by using the developed optimization methodology employing harmony search algorithm. The proposed method is presented with single degree of freedom and multiple degree of freedom structures. Results show that the coupled design is not effective on multiple degree of freedom adjacent structures. The coupled design is only effective for rigid structures with a single degree of freedom while the use of independent TMDs are effective on both rigid and flexural structures.

A new study in designing MTMDs in SDOF and MDOF systems based on the spectral analysis method

  • Baigoly, Morteza;Shargh, Farzan H.;Rofooei, Fayaz R.
    • Earthquakes and Structures
    • /
    • 제19권4호
    • /
    • pp.243-259
    • /
    • 2020
  • This study aims to optimize, design, and predict the MTMDs performance in SDOF systems using spectral analysis, and then apply their results to MDOF structures. Given the importance of spectral analysis in the design of new engineering structures, achieving a method for designing TMDs based on this theory can be of great importance for structural designers. In this study, several convenient combinations of MTMDs in an SDOF system are first considered to minimize the maximum displacement. For calculating the frequency ratios of dampers, an innovative technique is adopted in which the values of different modal responses obtained from the spectral analysis are approached together. This procedure is done using a harmony search (HS) algorithm. Also, using the random vibration theory, the damping ratio of the dampers is obtained. Then, an equation is presented for predicting the performance of MTMDs. For evaluating this equation, three structures with different stories are designed. Some of the presented combinations of dampers are added to them. The time history analyses are employed to analyze the structures under 30 different accelerograms. The findings indicated that the proposed equation could efficiently predict the performance of the MTMDs. Furthermore, four different patterns of damper distribution along the height of the structures are defined. The effect of them on the maximum deformation of the structures in time history analyses is discussed, and an equation is presented to estimate this effect. The results indicated that the average and maximum error percentages of the proposed equations are about three and seven percent, respectively, compared to the time history analyses results, which are negligible values.

에너지 소산형 감쇠기를 이용한 철근콘크리트 전단벽-골조 시스템의 진동제어 (Vibration Control of Shear Wall-Frame System using Energy Dissipation Devices)

  • 박지훈;김길환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.578-581
    • /
    • 2007
  • In this study, the seismic control performance of energy dissipation devices installed in a shear all-frame structure is investigated through nonlinear time history analysis of a 12-story building. Inelastic shear walls are modeled using the multiple vertical line element model (MVLEM) and inelastic columns and girders were modeled using fiber beam elements. For a seismic load increased by 38% compared to the design load, the seismic control performance was analyzed based on the results of a nonlinear time history analysis in terms of the inter-story drift, the story shear and the flexural strain. Friction type dampers was found to performs best if they are installed in the form of a brace adjacent to the shear wall with the friction force of 15 % of the maximum story shear force induced in the original building structure without dampers.

  • PDF

다중재난하중을 받는 인접건물의 연결제어에 대한 연구 (Research on Coupling Control of Adjacent Buildings under Multiple Hazards)

  • 곽신영;김현수
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.36-41
    • /
    • 2016
  • 본 논문에서는 다중재난하중을 받는 인접건물의 동적응답에 대한 연결제어기법의 제어성능을 수치해석적인 방법을 사용하여 검토하였다. 이를 위하여 강진지역인 LA 지역의 지진하중과 강풍지역인 찰스턴 지역의 풍하중을 사용하여 수치해석을 수행하였다. 인공 지진하중과 풍하중은 ASCE 7-10을 바탕으로 생성하였고 인공지진하중은 SIMQKE을 사용하여 작성하였으며 인공풍하중은 Kaimal Spectrum을 이용하여 작성하였다. 10층 및 20층의 인접구조물을 예제구조물로 사용하였고 비선형 이력댐퍼를 이용하여 연결제어를 하였다. 비선형 이력댐퍼를 간편하게 모형화하기 위하여 주로 MR 감쇠기를 모형화 할 때 사용하는 Bouc-Wen 모델을 사용하였다. 비선형 이력댐퍼는 10층에만 설치한 경우와 1층에서 10층까지 모든 층에 설치한 경우에 대해서 고려하였다. 각 층에 사용하는 댐퍼의 개수를 증가시킨 파라메터 스터디를 수행하였고 지진하중 및 풍하중에 대한 최적의 성능을 보이는 설계안을 검토하였다. 수치해석결과 비선형 이력댐퍼를 이용한 연결제어를 통하여 다중재난 하중에 대한 인접건물의 동적응답을 효과적으로 저감시킬 수 있었고 각각의 재난하중에 대한 최적설계결과가 다르게 나타나는 것을 확인할 수 있었다. 또한 연결되는 감쇠기를 과도하게 사용하면 오히려 구조물의 응답을 증가시킬 수 있으므로 주의 깊은 설계과정이 필요함을 알 수 있었다.

압전 분기회로를 이용한 다중모드제어 (Multiple-Mode Vibration Control Using Piezoelectric Shunted Actuator)

  • 박철휴
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.202-207
    • /
    • 2002
  • This paper deals with a novel shunted actuator, which has a capability to suppress multi-mode vibration amplitudes by using a pair of piezoceramic patches. In order to describe the characteristic behaviors of shunted dampers connected with a series and a parallel resistor-negative capacitive branch circuit, the stiffness ratio and loss factor with respect to the non-dimensional frequency are considered. To obtain a guideline model of a piezo/beam system connected with a series and a parallel resistor-negative capacitor branch circuit, the governing equations of motion is derived through Hamiltons principle and a piezo sensor equation as well as a shunt damping matrix is developed. The theoretical analysis shows that the shunted actuator developed in this study can significantly reduce multiple-mode vibration amplitudes simultaneously over the whole structural frequency range.

  • PDF

방화Damper의 성능기준 고찰 (Investigation of Performent Standards for the Fire Damper)

  • 조중달
    • 방재기술
    • /
    • 통권12호
    • /
    • pp.10-17
    • /
    • 1992
  • Dampers which being installad in air duct are Valume damper, fire damper, leakage rated damper, but among them fire damper and leakage rated damper are used for preventing the spread of flame, hot gas and smoke through the duct. this report is aimed to intorduce the test example of the multiple fire damper which was conducted F.I.L.K, simuetaneously to investigate the performent standards and Structure of the fire damper which settled in several countries.

  • PDF