• Title/Summary/Keyword: multiple blocks

Search Result 258, Processing Time 0.023 seconds

Assessment of effect of accelerated aging on interim fixed dental materials using digital technologies

  • Omar, Alageel;Omar, Alsadon;Haitham, Almansour;Abdullah, Alshehri;Fares, Alhabbad;Majed, Alsarani
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.360-368
    • /
    • 2022
  • PURPOSE. This study assessed the physical and mechanical properties of interim crown materials fabricated using various digital techniques after accelerated aging. MATERIALS AND METHODS. Three groups of interim dental restorative materials (N = 20) were tested. The first group (CO) was fabricated using a conventional manual method. The second group (ML) was prepared from prefabricated resin blocks for the milling method and cut into specimen sizes using a cutting disc. The third group (3D) was additively manufactured using a digital light-processing (DLP) 3D printer. Aging acceleration treatments using toothbrushing and thermocycling simulators were applied to half of the specimens corresponding to three years of usage in the oral environment (N = 10). Surface roughness (Ra), Vickers microhardness, 3-point bending, sorption, and solubility tests were performed. A 2-way analysis of variance (ANOVA) and Fisher's multiple comparison test were used to compare the results among the groups. RESULTS. The mean surface roughness (Ra) of the resin after accelerated aging was significantly higher in the CO and ML groups than that before aging, but not in the 3D group. All groups showed reduced hardness after accelerated aging. The flexural strength values were highest in the 3D group, followed by the ML and CO groups after accelerated aging. Accelerated aging significantly reduced water sorption in the ML group. CONCLUSION. According to the tested material and 3D printer type, both 3D-printed and milled interim restoration resins showed higher flexural strength and modulus, and lower surface roughness than those prepared by the conventional method after accelerated aging.

Evaluation of P57, P53 and Ki67 Expression in Meningiomas

  • Kucukosmanoglu, Ilknur;Karanis, Meryem Ilkay Eren;Unlu, Yasar;Coven, Ilker
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.499-506
    • /
    • 2022
  • Objective : We conducted this study with the aim of predicting the biological behavior of meningiomas, and determining the benefits of associating histological subtype and grade with the expression of proliferative markers and tumor suppressor proteins. Methods : The study included 29 patients with primary intracranial and intraspinal meningioma diagnosed in the pathology laboratory of Konya City Hospital between January 2014 and December 2020. Clinicopathological characteristics of the patients including parameters such as age and gender were obtained from the hospital records. Histopathological findings were obtained by re-evaluating the preparations stained with Hematoxylin-Eosin, which were extracted from the archive, and by evaluating new sections obtained from paraffin blocks of patients stained with Ki67, p53, and p57 immunohistochemical stains. Results : A moderate correlation was found between tumor size and Ki67 proliferation index (PI) (p=0.003, r=0.530). There was no significant difference between grade I and grade II tumors in terms of p53 (p=0.184) and p57 (p=0.487) expressions. There were higher levels of Ki67 PI in grade II tumors. The histological subtypes of the tumor had no significant difference with Ki67 PI (p=0.018), p53 (p=0.662), and p57 (p=0.368) expressions. Conclusion : In order to obtain more definitive results, there is a need for studies, which are conducted with a greater number of patients and in multiple centers, and in which a long prospective follow-up is planned. The combination of histological, surgical, and imaging markers could make a more sensitive tool for predicting recurrence, and this could also be tested in future studies.

A Disk-based Archival Storage System Using the EOS Erasure Coding Implementation for the ALICE Experiment at the CERN LHC

  • Ahn, Sang Un;Betev, Latchezar;Bonfillou, Eric;Han, Heejune;Kim, Jeongheon;Lee, Seung Hee;Panzer-Steindel, Bernd;Peters, Andreas-Joachim;Yoon, Heejun
    • Journal of Information Science Theory and Practice
    • /
    • v.10 no.spc
    • /
    • pp.56-65
    • /
    • 2022
  • Korea Institute of Science and Technology Information (KISTI) is a Worldwide LHC Computing Grid (WLCG) Tier-1 center mandated to preserve raw data produced from A Large Ion Collider Experiment (ALICE) experiment using the world's largest particle accelerator, the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN). Physical medium used widely for long-term data preservation is tape, thanks to its reliability and least price per capacity compared to other media such as optical disk, hard disk, and solid-state disk. However, decreasing numbers of manufacturers for both tape drives and cartridges, and patent disputes among them escalated risk of market. As alternative to tape-based data preservation strategy, we proposed disk-only erasure-coded archival storage system, Custodial Disk Storage (CDS), powered by Exascale Open Storage (EOS), an open-source storage management software developed by CERN. CDS system consists of 18 high density Just-Bunch-Of-Disks (JBOD) enclosures attached to 9 servers through 12 Gbps Serial Attached SCSI (SAS) Host Bus Adapter (HBA) interfaces via multiple paths for redundancy and multiplexing. For data protection, we introduced Reed-Solomon (RS) (16, 4) Erasure Coding (EC) layout, where the number of data and parity blocks are 12 and 4 respectively, which gives the annual data loss probability equivalent to 5×10-14. In this paper, we discuss CDS system design based on JBOD products, performance limitations, and data protection strategy accommodating EOS EC implementation. We present CDS operations for ALICE experiment and long-term power consumption measurement.

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

Shear bond strength of a self-adhesive resin cement to resin-coated dentin (간접수복용 복합레진과 자가 접착 레진 시멘트의 전단결합강도에 레진코팅법이 미치는 영향)

  • Hong, Jee-Youn;Park, Cheol-Woo;Heo, Jeong-Uk;Bang, Min-Ki;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The aims of this study were to evaluate the effect of a resin coating on the shear bond strength of indirect composite restoration bonded to dentin with a self adhesive resin cement and to compare the shear bond strength with that of a conventional resin cement. Materials and methods: The occlusal enamels of thirty six extracted noncarious human molars were removed until the dentin flat surfaces of the teeth were exposed. Then, they were divided into 3 groups. The dentin surfaces of group 1 and 3 were left without any conditioning, while the dentin surfaces of group 2 were resin-coated with Clearfil SE bond and a flowable resin composite, Metafil Flo. After all specimens were temporized for 24 hours, indirect composite resin blocks fabricated by Tescera were bonded to dentins by Unicem for group 1 and 2, and by Panavia F for group 3. After 48 hours of water storage, shear bond strengths were measured. The data was analyzed with one-way analysis of variance and multiple comparison test (Tukey method). Results: The shear bond strengths of Unicem applied to resin coated dentin surfaces were significantly higher than those of Unicem and Panavia F used to uncoated dentin surfaces (P<.0001). Conclusion: Application of a resin coating to the dentin surface significantly improved the shear bonding strength of a self adhesive resin cement in indirect restoration.

Influence of root canal curvature on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 근관의 만곡도가 니켈-티타늄 전동 파일의 screw-in effect에 미치는 영향)

  • Son, Ji-Young;Ha, Jung-Hong;Kim, Young-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.374-379
    • /
    • 2010
  • Objectives: Nickel-titanium (Ni-Ti) rotary instruments have some unexpected disadvantages including the tendency to screw-in to the canal. The purpose of this study was to evaluate the influence of root canal curvatures on the screw-in effect of Ni-Ti rotary files. Materials and Methods: A total of 80 simulated root canals in clear resin blocks were used in the study. Canals with curvature of 0, 10, 20 and 30 degrees were instrumented with ProTaper instruments SX, S1, S2 and a ProFile of #25/0.06 to 1.0-2.0 mm beyond the initial point of root curvature. The screw-in force was measured with a specially designed device while canal was instrumented with a ProFile of #30/0.06 at a constant speed of 300 rpm. The data were subjected to one-way ANOVA and Scheffe multiple range test for post-hoc test. Results: Larger degree of canal curvature generated significantly lesser screw-in forces in all groups (p < 0.001). Conclusions: More attention needs to be paid when using rotary instruments in canals with less curvature than canals with more curvatures to prevent or reduce any accidental overinstrumentation.

A Crypto-processor Supporting Multiple Block Cipher Algorithms (다중 블록 암호 알고리듬을 지원하는 암호 프로세서)

  • Cho, Wook-Lae;Kim, Ki-Bbeum;Bae, Gi-Chur;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2093-2099
    • /
    • 2016
  • This paper describes a design of crypto-processor that supports multiple block cipher algorithms of PRESENT, ARIA, and AES. The crypto-processor integrates three cores that are PRmo (PRESENT with mode of operation), AR_AS (ARIA_AES), and AES-16b. The PRmo core implementing 64-bit block cipher PRESENT supports key length 80-bit and 128-bit, and four modes of operation including ECB, CBC, OFB, and CTR. The AR_AS core supporting key length 128-bit and 256-bit integrates two 128-bit block ciphers ARIA and AES into a single data-path by utilizing resource sharing technique. The AES-16b core supporting key length 128-bit implements AES with a reduced data-path of 16-bit for minimizing hardware. Each crypto-core contains its own on-the-fly key scheduler, and consecutive blocks of plaintext/ciphertext can be processed without reloading key. The crypto-processor was verified by FPGA implementation. The crypto-processor implemented with a $0.18{\mu}m$ CMOS cell library occupies 54,500 gate equivalents (GEs), and it can operate with 55 MHz clock frequency.

[ $Gd(DTPA)^{2-}$ ]-enhanced, and Quantitative MR Imaging in Articular Cartilage (관절연골의 $Gd(DTPA)^{2-}$-조영증강 및 정량적 자기공명영상에 대한 실험적 연구)

  • Eun Choong-Ki;Lee Yeong-Joon;Park Auh-Whan;Park Yeong-Mi;Bae Jae-Ik;Ryu Ji Hwa;Baik Dae-Il;Jung Soo-Jin;Lee Seon-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.100-108
    • /
    • 2004
  • Purpose : Early degeneration of articular cartilage is accompanied by a loss of glycosaminoglycan (GAG) and the consequent change of the integrity. The purpose of this study was to biochemically quantify the loss of GAG, and to evaluate the $Gd(DTPA)^{2-}$-enhanced, and T1, T2, rho relaxation map for detection of the early degeneration of cartilage. Materials and Methods : A cartilage-bone block in size of $8mm\;\times\;10mm$ was acquired from the patella in each of three pigs. Quantitative analysis of GAG of cartilage was performed at spectrophotometry by use of dimethylmethylene blue. Each of cartilage blocks was cultured in one of three different media: two different culture media (0.2 mg/ml trypsin solution, 1mM Gd $(DTPA)^{2-}$ mixed trypsin solution) and the control media (phosphate buffered saline (PBS)). The cartilage blocks were cultured for 5 hrs, during which MR images of the blocks were obtained at one hour interval (0 hr, 1 hr, 2 hr, 3 hr, 4 hr, 5 hr). And then, additional culture was done for 24 hrs and 48 hrs. Both T1-weighted image (TR/TE, 450/22 ms), and mixed-echo sequence (TR/TE, 760/21-168ms; 8 echoes) were obtained at all times using field of view 50 mm, slice thickness 2 mm, and matrix $256\times512$. The MRI data were analyzed with pixel-by-pixel comparisons. The cultured cartilage-bone blocks were microscopically observed using hematoxylin & eosin, toluidine blue, alcian blue, and trichrome stains. Results : At quantitation analysis, GAG concentration in the culture solutions was proportional to the culture durations. The T1-signal of the cartilage-bone block cultured in the $Gd(DTPA)^{2-}$ mixed solution was significantly higher ($42\%$ in average, p<0.05) than that of the cartilage-bone block cultured in the trypsin solution alone. The T1, T2, rho relaxation times of cultured tissue were not significantly correlated with culture duration (p>0.05). However the focal increase in T1 relaxation time at superficial and transitional layers of cartilage was seen in $Gd(DTPA)^{2-}$ mixed culture. Toluidine blue and alcian blue stains revealed multiple defects in whole thickness of the cartilage cultured in trypsin media. Conclusion : The quantitative analysis showed gradual loss of GAG proportional to the culture duration. Microimagings of cartilage with $Gd(DTPA)^{2-}$-enhancement, relaxation maps were available by pixel size of $97.9\times195\;{\mu}m$. Loss of GAG over time better demonstrated with $Gd(DTPA)^{2-}$-enhanced images than with T1, T2, rho relaxation maps. Therefore $Gd(DTPA)^{2-}$-enhanced T1-weighted image is superior for detection of early degeneration of cartilage.

  • PDF

Targeted Therapies and Radiation for the Treatment of Head and Neck Cancer (두경부 암의 표적 지향적 방사선 치료)

  • Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.77-90
    • /
    • 2004
  • Purpose: The purpose of this review Is to provide an update on novel radiation treatments for head and neck cancer Recent Findings: Despite the remarkable advances In chemotherapy and radiotherapy techniques, the management of advanced head and neck cancer remains challenging. Epidermal growth factor receptor (EGFR) Is an appealing target for novel therapies In head and neck cancer because not only EGFR activation stimulates many important signaling pathways associated with cancer development and progression, and importantly, resistance to radiation. Furthermore, EGFR overexpression Is known to be portended for a worse outcome in patients with advanced head and neck cancer. Two categories of compounds designed to abrogate EGFR signaling, such as monoclonal antibodies (Cetuxlmab) and tyrosine kinase inhibitors (ZD1839 and 051-774) have been assessed and have been most extensively studied In preclinical models and clinical trials. Additional TKIs In clinical trials include a reversible agent, Cl-1033, which blocks activation of all erbB receptors. Encouraging preclinical data for head and neck cancers resulted In rapid translation Into the clinic. Results from Initial clinical trials show rather surprisingly that only minority of patients benefited from EGFR inhibition as monotherapy or In combination with chemotherapy. In this review, we begin with a brief summary of erbB- mediated signal transduction. Subsequently, we present data on prognostic-predictive value of erbB receptor expression in HNC followed by preclinlcal and clinical data on the role of EGFR antagonists alone or in combination with radiation In the treatment of HNC. Finally, we discuss the emerging thoughts on resistance to EGFR biockade and efforts In the development of multiple-targeted therapy for combination with chemotherapy or radiation. Current challenges for investigators are to determine (1 ) who will benefit from targeted agents and which agents are most appropriate to combine with radiation and/or chemotherapy, (2) how to sequence these agents with radiation and/or cytotoxlc compounds, (3) reliable markers for patient selection and verification of effective blockade of signaling in vivo, and (4) mechanisms behind intrinsic or acquired resistance to targeted agents to facilitate rational development of multi-targeted therapy, Other molecuiar-targeted approaches In head and neck cancer were briefly described, Including angloenesis Inhibitors, farnesyl transferase inhibitors, cell cycle regulators, and gene therapy Summary: Novel targeted theraples are highly appealing in advanced head and neck cancer, and the most premising strategy to use them Is a matter of intense Investigation.

Methods of Weighting Matrices Determination of Moving Double Poles with Jordan Block to Real Poles By LQ Control (LQ 제어로 조단블록이 있는 중근을 실근으로 이동시키는 가중행렬 결정 방법)

  • Park, Minho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.634-639
    • /
    • 2020
  • In general, the stability and response characteristics of the system can be improved by changing the pole position because a nonlinear system can be linearized by the product of a 1st and 2nd order system. Therefore, a controller that moves the pole can be designed in various ways. Among the other methods, LQ control ensures the stability of the system. On the other hand, it is difficult to specify the location of the pole arbitrarily because the desired response characteristic is obtained by selecting the weighting matrix by trial and error. This paper evaluated a method of selecting a weighting matrix of LQ control that moves multiple double poles with Jordan blocks to real poles. The relational equation between the double poles and weighting matrices were derived from the characteristic equation of the Hamiltonian system with a diagonal control weighting matrix and a state weighting matrix represented by two variables (ρd, ϕd). The Moving-Range was obtained under the condition that the state-weighting matrix becomes a positive semi-definite matrix. This paper proposes a method of selecting poles in this range and calculating the weighting matrices by the relational equation. Numerical examples are presented to show the usefulness of the proposed method.