• 제목/요약/키워드: multi-story steel frame

검색결과 52건 처리시간 0.029초

Global seismic performance of a new precast CFST column to RC beam braced frame: Shake table test and numerical study

  • Xu, S.Y.;Li, Z.L.;Liu, H.J.
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.805-827
    • /
    • 2016
  • A new type of precast CFST column to RC beam braced frame is proposed in this paper. A series of shake table tests were conducted to excite a one-third scale six-story model for investigating the global seismic performance of this type of structure against earthquake actions. Particular emphasis was given to its dynamic property, global seismic responses and failure path. Correspondingly, a numerical model built on the basis of fiber-beam-element model, multi-layer shell model and element-deactivation method was developed to simulate the seismic performance of the prototype structure. Numerical results were compared with the measured values from shake table tests to verify the validity and reliability of the numerical model. The results demonstrated that the proposed novel precast CFST column to RC beam braced frame performs excellently under strong earthquake excitations; the "strong CFST column-weak RC beam" and "strong connection-weak member" anti-seismic design principles can be easily achieved; the maximum deflections of precast CFSTC-RCB braced frame satisfied the deflection limitations proposed in national code; the numerical model can properly simulate the dynamic property and responses of the precast CFSTC-RCB braced frame that are highly concerned in engineering practice.

Damage assessment and performance-based seismic design of timber-steel hybrid shear wall systems

  • Li, Zheng;He, Minjuan;Li, Minghao;Lam, Frank
    • Earthquakes and Structures
    • /
    • 제7권1호
    • /
    • pp.101-117
    • /
    • 2014
  • This paper presents a reliability-based analysis on seismic performance of timber-steel hybrid shear wall systems. Such system is composed of steel moment resisting frame and infill wood frame shear wall. The performance criteria of the hybrid system with respect to different seismic hazard levels were determined through a damage assessment process, and the effectiveness of the infill wood shear walls on improving the seismic performance of the hybrid systems was evaluated. Performance curves were obtained by considering different target non-exceedance probabilities, and design charts were further established as a function of seismic weight. Wall drift responses and shear forces in wood-steel bolted connections were used as performance criteria in establishing the performance curves to illustrate the proposed design procedure. It was found that the presence of the infill wood shear walls significantly reduced the non-performance probabilities of the hybrid wall systems. This study provides performance-based seismic evaluations on the timber-steel hybrid shear walls in support of future applications of such hybrid systems in multi-story buildings.

Enhancing the Fire Performance of Concrete-Filled Steel Columns through System-Level Analysis

  • Fike, R.S.;Kodur, V.K.R.
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.11-21
    • /
    • 2013
  • The use of concrete filling offers a practical alternative for achieving the required stability of steel Hollow Structural Section (HSS) columns under fire conditions. However, current methods for evaluating fire resistance of Concrete Filled Hollow Structural Steel (CFHSS) columns are highly conservative as they are based on an elemental approach without due consideration to structural interactions that occur in framed structural systems. To overcome this limitation, a system level fire resistance analysis was carried out by treating CFHSS columns as part of an overall structural frame. In this analysis, an eight story steel-framed building was modeled under a range of standard and performance-based fire scenarios (including multi-story progressive burn-out fires) to evaluate the contribution of various structural members/assemblies to overall fire resistance. One of the primary factors considered was the use of concrete filling in HSS columns as an alternative to standard W-shape columns. Results from the analysis indicate that the use of CFHSS columns, in place of W-shape columns, in a performance-based environment can fully eliminate the need for applied fire protection to columns, while providing the required level of structural fire resistance.

Closed-form fragility analysis of the steel moment resisting frames

  • Kia, M.;Banazadeh, M.
    • Steel and Composite Structures
    • /
    • 제21권1호
    • /
    • pp.93-107
    • /
    • 2016
  • Seismic fragility analysis is a probabilistic decision-making framework which is widely implemented for evaluating vulnerability of a building under earthquake loading. It requires ingredient named probabilistic model and commonly developed using statistics requiring collecting data in large quantities. Preparation of such a data-base is often costly and time-consuming. Therefore, in this paper, by developing generic seismic drift demand model for regular-multi-story steel moment resisting frames is tried to present a novel application of the probabilistic decision-making analysis to practical purposes. To this end, a demand model which is a linear function of intensity measure in logarithmic space is developed to predict overall maximum inter-story drift. Next, the model is coupled with a set of regression-based equations which are capable of directly estimating unknown statistical characteristics of the model parameters.To explicitly address uncertainties arise from randomness and lack of knowledge, the Bayesian regression inference is employed, when these relations are developed. The developed demand model is then employed in a Seismic Fragility Analysis (SFA) for two designed building. The accuracy of the results is also assessed by comparison with the results directly obtained from Incremental Dynamic analysis.

철골 구조물의 제진 및 면진성능 (Damping and Isolation Performance of Steel Structure)

  • 윤현도;박완신;한병찬;황선경;이규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.221-230
    • /
    • 2004
  • 본 논문에서는 지진하중 작용시, 점탄성 감쇠기 및 면진장치를 설치한 다층 철골 모멘트 저항 골조의 동적응답을 해석적으로 규명하였다. 본 연구의 목적은 구조해석을 수행하여 최대 층간변위 및 최대응력법에 의해 효율적인 점탄성 감쇠기의 위치를 결정하는 것이다. 또한, 효율적인 진동 제어방법을 모색하기 위하여 점탄성 감쇠기 및 납삽입고무베어링형 면진장치에 의한 제어효과를 부재력, 조합응력, 그리고 구조물의 고유주기 등을 이용하여 상호 비교 분석하였다.

Development of a simplified equivalent braced frame model for steel plate shear wall systems

  • Chatterjee, Arghya Kamal;Bhowmick, Anjan;Bagchi, Ashutosh
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.711-737
    • /
    • 2015
  • Steel Plate Shear Walls (SPSWs) have been accepted widely as an effective lateral load resisting system. For seismic performance evaluation of a multi-story building with SPSWs, detailed finite element models or a strip model can be used to represent the SPSW components. However, such models often require significant effort for tall or medium height buildings. In order to simplify the analysis process, discrete elements for the framing members can be used. This paper presents development of a simplified equivalent braced model to study the behavior of the SPSWs. The proposed model is expected to facilitate a simplification to the structural modeling of large buildings with SPSWs in order to evaluate the seismic performance using regular structural analysis tools. It is observed that the proposed model can capture the global behavior of the structures quite accurately and potentially aid in the performance-based seismic design of SPSW buildings.

Assessment of Post-Earthquake Fire Behavior of a Steel MRF Building in a Low Seismic Region

  • Chicchi, Rachel;Varma, Amit
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1470-1481
    • /
    • 2018
  • Building-level response to post-earthquake fire hazards in steel buildings has been assessed using primarily two-dimensional analyses of the lateral force resisting system. This approach may not adequately consider potential vulnerabilities in the gravity framing system. For this reason, three-dimensional (3D) finite element models of a 10-story case study building with perimeter moment resisting frames were developed to analyze post-earthquake fire events and better understand building response. Earthquakes are simulated using ground motion time histories, while Eurocode parametric time-temperature curves are used to represent compartment fires. Incremental dynamic analysis and incremental fire analysis procedures capture a range of hazard intensities. Findings show that the structural response due to earthquake and fire hazards are somewhat decoupled from one another. Regardless of the level of plastic hinging present in the moment framing system due to a seismic event, gravity column failure is the initiating failure mode in a fire event.

부분 강절 골조의 응력 해석 (Stress Analysis of Semi-Rigid Frame)

  • 김선혜;김순철;이수곤
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.306-313
    • /
    • 1998
  • Contrary to reinforced concrete frames, the beams or girders found in actual steel frames are neither hinged nor fixed at their ends. Instead, they are usually restrained by the columns to which they are attached. Here in this paper, common finite element program for plane frame stress analysis is improved by including the effect of partial fixities of the girder ends. To include the effect of partial fixities of the girder ends, Kim's modified slope-deflection equation is adopted. The stress analysis results obtained by this proposed method are then compared with Kim's example. Finally, method of choosing the most economic girder section for a multi-story frame is suggested through the examples.

  • PDF

Seismic control performance and experimental study of multiple pounding tuned rolling mass damper

  • Peiran Fan;Shujin Li;Ling Mao
    • Earthquakes and Structures
    • /
    • 제24권4호
    • /
    • pp.247-258
    • /
    • 2023
  • Multiple pounding tuned rolling mass damper (MPTRMD) distributed in the cavity of voided slabs is proposed to passively control multi-story frame structures, which disperses the mass of the oscillator to multiple dampers so that the control device can be miniaturized without affecting the vibration control performance. The mechanism and the differential motion equations of the MPTRMD-controlled multi-degree-of-freedom system are derived based on the Lagrange principle. Afterward, this advanced RMD is applied to a simplified 20-floor steel frame to evaluate the seismic control performance in the numerical analysis. A four-storey frame structure equipped with MPTRMD is then taken for a shaking table test to verify its effectiveness of control performance. The pounding mechanism has been detailed studied numerically and experimentally as well. The numerical and experimental results show that the proposed damper is practically promising not only for its prominent control performance but also for its lightweight and space-saving. Additionally, the pounding mechanism influenced by the variable impact parameters exhibits a balance between the two effects of motional limitations and energy dissipation.

이중골조시스템으로 설계된 복강판-모듈러 구조물의 반응수정계수에 관한 연구 (Study on the Response Modification Factor for a Lightweight Steel Panel-Modular Structure Designed as a Dual Frame System)

  • 이어진;홍성걸
    • 한국지진공학회논문집
    • /
    • 제15권1호
    • /
    • pp.39-48
    • /
    • 2011
  • 본 연구에서는 복강판-모듈러 시스템과 같이 구조 기준에 명시되지 않은 새로운 시스템의 반응수정계수를 산정하는 절차를 제안하였다. 기본 개념은 구조성능 실험결과를 바탕으로 모델링 된 시스템의 비선형 정적 해석 곡선으로부터 세부 구성요소인 초과강도계수와 연성계수의 도출하고, 단자유도 시스템으로 간주하고 평가된 반응수정계수를 다자유도 동적 거동을 고려한 다자유도 밑면전단 수정계수로 수정하여 시스템의 최종적인 반응수정계수를 결정하는 것이다. 제안한 절차에 따라 이중골조시스템으로 설계된 2층부터 5층까지의 복강판-모듈러 시스템에 대해 평가한 결과, 최종적인 반응수정계수는 5층(층고 4m기준)을 복강판-모듈러 시스템의 적용 가능한 층수의 상한으로 하여 4로 결정하는 것이 타당할 것으로 판단하였다.