• 제목/요약/키워드: multi-mode

검색결과 1,751건 처리시간 0.025초

SDR시스템에서 소프트웨어 다운로드 측면에서의 동적 재구성(Dynamic Reconfigurability) (Dynamic Reconfigurability of the aspect of software download in SDR)

  • 서정민;이병호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.422-425
    • /
    • 2003
  • Software reconfigurable radio will give future users a number of benefits like global roaming, multi mode, multi band, and multi standard. It will also offer complete programmability and reconfigurability to both multi mode and multi functional communication terminal and network nodes. This configuration will be implemented by application of different combination of radio configurable software. In this paper, It proposes the algorithm needed for reconfiguration with basic explanation of the software download. A description of an implementation such reconfiguration processes as partial download and full download and critical and non-critical download installation using the registration table in included.

  • PDF

토목관련 천부층 조사에서 다중 모드 표면파 역산의 효과 (Effectiveness of multi-mode surface wave inversion in shallow engineering site investigations)

  • Feng Shaokong;Sugiyama Takeshi;Yamanaka Hiroaki
    • 지구물리와물리탐사
    • /
    • 제8권1호
    • /
    • pp.26-33
    • /
    • 2005
  • 최근 들어 토목관련 천부층 조사에 다중 모드 표면파 위상 속도의 역산이 많은 관심을 받고 있다. 감도 분석, 그리고 합성탄성파자료와 현장자료의 역산 결과는 이 방법이 기본 모드만을 이용하는 것에 비해 매우 효과적임을 보여주고 있다. 이중 모드 레일리 파의 위상속도들에서 층의 두께와 전단파 속도에서의 조그만 변화는 고차 모드의 감도들을 (a) 다른 주파수 대역들에 모이게 하고 (b) 심도가 깊어질수록 기본 모드보다도 더 크게 한다. 이 관찰을 통해 다중 모드 위상 속도 역산을 이용하면 기본 모드 자료들만의 역산에 비해 변수값들을 더 잘 구분해 낼 수 있고 깊은 구조, 특히 속도 역전이 일어난 구조에 대해 보다 나은 영상을 얻을 수 있음을 알 수 있다. 20 m 깊이에 저속도층이 존재하는 모델에서 이론적인 위상 속도들의 역산은 1차 모드만 첨가될 때 단지 연암층만을 영상화할 수 있다. 이 사실은 측정 가능한 가장 낮은 주파수가 단지 6 Hz 일 때 특히 중요하다. 현장시험들이 시추공과 PS 검층을 이용하여 조사된 지역들에서 행해졌다. 첫 번째 지역에서는 일본에서 심부 지질조사에 주로 이용되는 microtremor 배열 탐사가 35 m 깊이까지 토양층을 탐사하기 위해 사용되었다. 두 번째 지역에서는 12 m 깊이까지 조사하기 위해 sledgehammer 음원과 선형 다중 채널 수진기 전개를 이용하여 자료가 얻어졌다. 분산곡선 분석을 위해서 주파수-파수 파워 스펙트럼법이 사용되었고 각각의 시험에서 2차 모드의 속도까지 구해졌다. 다중 모드 역산 결과는 PS 검층기록과 잘 일치한다. 하지만 단지 기본 모드만을 이용하여 얻어진 결과는 매립지 아래의 천부 연암층까지의 깊이를 매우 작게 평가하였다.

중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제 (Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection)

  • 배영상;김래영
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.31-40
    • /
    • 2014
  • This paper describes an optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants. We theoretically analyze a proposed common-mode equivalent model for problems associated with multi-central transformerless-type three-phase full bridge(3-FB) PV inverters employing two-winding MV transformers. We propose a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur. In addition, we propose that the existing 3-FB topology may also have the configuration of a multi-central inverter with a two-winding MV transformer by making a simple circuit modification. Simulation and experimental results of three 350kW PV inverters in a multi-central configuration verify the effectiveness of the proposed synchronization control strategy. The modified transformerless-type 3-FB topology for a multi-central PV inverter configuration is verified using an experimental prototype of a 100kW PV inverter.

ANALYSIS OF PLANETARY GEAR HYBRID POWERTRAIN SYSTEM PART 1: INPUT SPLIT SYSTEM

  • Yang, H.;Cho, S.;Kim, N.;Lim, W.;Cha, S.
    • International Journal of Automotive Technology
    • /
    • 제8권6호
    • /
    • pp.771-780
    • /
    • 2007
  • In recent studies, various types of multi mode electric variable transmissions of hybrid electric vehicles have been proposed. Multi mode electric variable transmission consists of two or more different types of planetary gear hybrid powertrain system(PGHP), which can change its power flow type by means of clutches for improving transmission efficiencies. Generally, the power flows can be classified into three different types such as input split, output split and compound split. In this study, we analyzed power transmission characteristics of the possible six input split systems, and found the suitable system for single or multi mode hybrid powertrain. The input split system used in PRIUS is identified as a best system for single mode, and moreover we identified some suitable systems for dual mode.

멀티레벨 인버터를 이용한 3상 유도전동기 구동 시스템의 EMI 필터 설계 (Design of EMI filters for an Induction Motor Drive System with Multi-level inverters)

  • 김수홍;안영오;방상석;김광섭;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.265-270
    • /
    • 2006
  • In this paper EMI problems with induction motor drive system using multi-level inverters are investigated. The high power multi-level inverter usually operates with low switching frequency and produces large noises. Generally, EMI consists of the conduction component through source lines and emission component emitted to the space. This conduction component can be classified to the common-mode between source line and ground, and the normal-mode between lines. The EMI filters for the induction motor drive system are designed and implemented to reduce EMI noise. Finally the designed system is verified by the experiment. The experimental results show that both the normal mode and common mode noises are greatly reduced compared to the system without filters.

슬라이딩 모우드 제어에 기초한 유연한 2링크 조작기의 진동제어 (Vibration Control of a Flexible Two-link Manipulator based on the Sliding Mode Control)

  • 채승훈;양현석;박영필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.511-516
    • /
    • 2000
  • In order to not only perform as a extreme model under the severe operating condition but also acquire more diverse and advanced control capability utilizing high compliance, active vibration control of a flexible 2-link robot manipulator are investigated. Multi variable-structured frequency shaped optimal sliding mode is proposed for the flexible robot manipulator like control system, whose control variables, an angular motion of joint and vibration of flexible link, have to be controlled simultaneously by one control torque at a driving joint. The control system is divided into two subsystems, a control input related subsystem and an added subsystem. The proposed sliding mode, composed of multi control variables, makes optimized relation between subsystems and a individual control input, thus, the sliding mode controller can compensate whole dynamics of each subsystems simultaneously. And the possibility and effectiveness are verified by vibration control of a manipulator having two flexible links. Simulation and experiment results show that the proposed control scheme achieves the purpose effectively.

  • PDF

불연속 전류모드에서의 다상 교호 강압컨버터의 정상상태 해석 및 모델링 (Modeling and Steady-state Analysis of the Multi-Phase Interleaved Buck converter in Discontinuous Inductor Current Mode)

  • 장성동;장은승;정세교;신휘범;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.506-510
    • /
    • 2004
  • A multi-phase interleaved buck converter is used to reduce current ripples and filter size of a power supply. This paper addresses the modelling and steady-state analysis of the multi-phase interleaved buck converter operated in discontinuous inductor current mode. The model is derived using an averaging technique in steady state. The do voltage ratio and the range of the discontinuous inductor current mode(DICM) and the continuous output current mode(COCM) are derived from the averaged state-space model. In addition, the efficiency is investigated according to the number of phase.

  • PDF

다기능 케이블을 위한 연성 회로 기판에 내장된 공통 모드 필터 (Common Mode Filter Embedded in Flexible Printed Circuit Board for Multi-Function Cable)

  • 변진도;정상운;이근형;이해영
    • 한국전자파학회논문지
    • /
    • 제19권3호
    • /
    • pp.343-351
    • /
    • 2008
  • 본 논문에서는 FPC(Flexible Printed Circuit) 케이블에 적층된 나선형 인덕터를 내장하여 다기능 케이블을 위한 공통 모드 필터를 제안하였다. 공통 모드 필터가 내장된 FPC 케이블은 별도의 SMD(Surface Mounted Device) 필터 없이 연성 케이블과 공통 모드 차단 특성을 가짐으로서, 다기능 케이블이라는 새로운 개념을 제시한다. 내장된 공통 모드 필터는 광대역의 공통 모드 차단 대역을 가지고 손실이 큰 페라이트와 같은 자성 물질을 사용하지 않아 차동 모드 삽입 손실 및 반사 손실이 향상되었다. 3-turn 인덕터를 가진 공통 모드 필터는 공통 모드차단 대역이 $0.4{\sim}3.12GHz$이며, 페라이트를 적용한 상용 LTCC(Low Temperature Co-fire Ceramic) 공통 모드 필터에 비해 3 GHz에서 1.95 dB, 8 GHz에서 6.97 dB의 향상된 차동 모드 삽입 손실을 갖는다.

슬라이딩 모드를 이용한 다관절 매니퓰레이터의 다입력 실시간 제어에 관한 연구 (A study on a multi-input time control of multi-joint manipulator using sliding mode)

  • 이민철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.652-657
    • /
    • 1992
  • This paper presents to accomplish successfully a multi-input real time control by applying control hierarchy for sliding mode of multi-joint manipulators whose nonlinear terms are regarded as disturbances. We- could simplify the dynamic equations of a manipulator and servo system, which are composed of linear elements and nonlinear elements, by assuming that nonlinear terms, which are Inertia term, gravity force term, Coriolis force term and centrifugal force term, are external disturbance. By simplifying that equation, we could easily obtain a control input which satisfy sliding mode of multi-input system. We proposed a new control input algorithm in order to decrease chattering by changing control input according as effect of disturbance if a control response become within allowance error range. In this experiments, we used DSP(Digital Signal Processor) controller to suppress chattering by time delay of calculation and to carry out real time control.

  • PDF

QAM 복조용 새로운 다단계 자력복구 군집형 채널등화기 (New Multi-Stage Blind Clustering Equalizers for QAM Demodulation)

  • 황유모;이중현;송진호
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권5호
    • /
    • pp.269-277
    • /
    • 2000
  • We propose two new types multi-stage blind clustering equalizers for QAM demoulation, which are called a complex classification algorithm(CCA) and a radial basis function algorithm(RBFA). The CCA uses a clustering technique based on the joint gaussian probability function and computes separately the real part and imaginary part for simple implementation as well as less computation. In order to improve the performance of CCA, the Dual-Mode CCA(DMCCA) incorporates the CCA tap-updating mode with the decision-directed(DD) mode. The RBFA reduces the number of cluster centers through three steps using the classification technique of RBF and then updates the equalizer taps for QAM demodulation. Test results on 16-QAM confirm that the proposed algorithms perform better the conventional multi-state equalizers in the senses of SER and MSE under multi-path fading channel.

  • PDF