• Title/Summary/Keyword: multi-electrode

Search Result 413, Processing Time 0.026 seconds

Improvement of The Saturation Voltage Characteristics of BJT Using Folded Back Electrode (Folded Back Electrode를 이용한 BJT의 포화전압특성 개선)

  • 김현식;손원소;최시영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.5
    • /
    • pp.15-21
    • /
    • 2004
  • In this paper a new structure of BJT is proposed to improve the saturation voltage characteristics so that it can be used to the low power switching devices. In the case of the conventional finger transistor(FT), the saturation voltage is so high that it dose not satisfy the requirements for the low power device. So the other multi base island transistor(MBIT) is suggested and its saturation voltage is so low in the region of low current that it satisfy the requirement for the low power switching devices, but in region of the high current the saturation voltage tends to increase so that it does not satisfy the requirements for the low power switching devices. So in this paper a new structure of folded back electrode transistor(FBET) is proposed and the characteristics is investigated. When the new structure is applied the emitter area is increased by 35 % so the saturation voltage is reduced by 30 % at the low current region and the contact area is increased by 92 % so the saturation voltage is reduced by totally f % at the high current region with the reduction of 30 % by the increase of the emitter area and the reduction of 7 % by the increase of the emitter contact area.

Effects of Bubble Discharge on pH and Oxidation/Reduction Potential Change by Non-Uniform Electric Field (불평등전계에 의한 기포방전이 수소이온농도와 산화환원전위변화에 미치는 영양)

  • 김진규;김광태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.77-82
    • /
    • 2003
  • In this paper, as the new type of multi-lines electrode which can formulate strong non-uniform electric field was installed in strong electrolytic water generator, shapes of pre-discharge in bubble and effects of bubble discharge on pH and oxidation/reduction potential change were intended to investigate. Consequently, as multi-lines electrode was installed in side of anode, pre-discharges generated from anode electrode could be observed. This pre-discharge was generated from differences of permittivities between bubble and water in strong non-uniform electric field. And ion concentration in electrolytic water generator was increased by dissolving of ions generated from bubble discharge. So, as generated high concentration ions were separated and assembled to each electrode and reaction of oxidation/reduction was increased, it was shown that strong electrolytic water could be generated.

Development of Large-area Plasma Sources for Solar Cell and Display Panel Device Manufacturing

  • Seo, Sang-Hun;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.148-148
    • /
    • 2011
  • Recently, there have been many research activities to develop the large-area plasma source, which is able to generate the high-density plasma with relatively good uniformity, for the plasma processing in the thin-film solar cell and display panel industries. The large-area CCP sources have been applied to the PECVD process as well as the etching. Especially, the PECVD processes for the depositions of various films such as a-Si:H, ${\mu}c$-Si:H, Si3N4, and SiO2 take a significant portion of processes. In order to achieve higher deposition rate (DR), good uniformity in large-area reactor, and good film quality (low defect density, high film strength, etc.), the application of VHF (>40 MHz) CCP is indispensible. However, the electromagnetic wave effect in the VHF CCP becomes an issue to resolve for the achievement of good uniformity of plasma and film. Here, we propose a new electrode as part of a method to resolve the standing wave effect in the large-area VHF CCP. The electrode is split up a series of strip-type electrodes and the strip-type electrodes and the ground ones are arranged by turns. The standing wave effect in the longitudinal direction of the strip-type electrode is reduced by using the multi-feeding method of VHF power and the uniformity in the transverse direction of the electrodes is achieved by controlling the gas flow and the gap length between the powered electrodes and the substrate. Also, we provide the process results for the growths of the a-Si:H and the ${\mu}c$-Si:H films. The high DR (2.4 nm/s for a-Si:H film and 1.5 nm/s for the ${\mu}c$-Si:H film), the controllable crystallinity (~70%) for the ${\mu}c$-Si:H film, and the relatively good uniformity (1% for a-Si:H film and 7% for the ${\mu}c$-Si:H film) can be obtained at the high frequency of 40 MHz in the large-area discharge (280 mm${\times}$540 mm). Finally, we will discuss the issues in expanding the multi-electrode to the 8G class large-area plasma processing (2.2 m${\times}$2.4 m) and in improving the process efficiency.

  • PDF

Effects of Multi-layer and TiCl4 Treatment for TiO2 Electrode in Dye-sensitized Solar Cell (염료감응 태양전지의 TiO2 전극의 다중층 및 TiCl4 처리에 따른 효과)

  • Kim, Gyeong-Ok;Kim, Ki-Won;Cho, Kwon-Koo;Ryu, Kwang-Sun
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.190-195
    • /
    • 2011
  • To investigate the photon-trapping effect and scattering layer effect of $TiO_2$ multi-layer in dye-sensitized solar cell (DSSC) and the degree of recombination of electrons at the electrode treated $TiCl_4$, we formed electrodes of different conditions and obtained the most optimal electrode conditions. To estimate characteristics of the cell, IV curve, UV-Vis spectrophotometer, electrochemical impedance spectroscopy (EIS) and incident photon-to-current conversion efficiency (IPCE) were measured. As a result, we confirmed that the multi-layer's efficiency was higher than that of monolayer in the IV curve and the performance of $TiCl_4$ treated electrode was increased according to decreasing the impedance of EIS. Among several conditions, the efficiency of the cell with scattering layer is higher than that of a layer with the base electrode about 19%. Because the light scattering layer enhances the efficiency of the transmission wavelength and has long electron transfer path. Therefore, the value of the short circuit current increases approximately 10% and IPCE in the maximum peak also increases about 12%.

A Study on the Development of Underwater Wet Welding Electrodes

  • Kim, Min-Nam
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.52-58
    • /
    • 2003
  • Underwater wet arc welds were experimentally performed on the KR-RA steel plate as base metal by using four different types of flux coated electrodes: KT33, UWEE, UWCS, and TN20, UWEE, the individually designed flux coated underwater electrode, had good operability when compared with other domestic terrestrial electrodes, and imported goods. The hardness value and the portion of martensite of HAZ were increased, by using a rapid cooling rate, Mechanical properties were also examined experimentally with a multi-pass butt-welding specimen test. The individually designed flux coated electrode UWEE could be used in practice for underwater wet welds.

A Study on the Development of Underwater Wet Welding Electrodes

  • Kim, Min-Nam
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.6 no.1
    • /
    • pp.75-81
    • /
    • 2003
  • Underwater wet arc welds were experimentally performed on the KR-RA steel plate as base metal by using four different types of flux coated electrodes: KT33, UWEE, UWCS, and TN20. UWEE, the individually designed flux coated underwater electrode, had good operability when compared with other domestic terrestrial electrodes, and imported goods. The hardness value and the portion of martensite of HAZ were increased, by using a rapid cooling rate, Mechanical properties were also examined experimentally with a multi-pass butt-welding specimen test. The individually designed flux coated electrode UWEE could be used in practice for underwater wet welds.

  • PDF

A Study on the Properties of Underwater Wet Arc Welding for the Mild Steels (연강의 습식 수중 아크 용접 특성에 관한 연구)

  • Kwak, H.H.;Kim, C.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.107-114
    • /
    • 2007
  • Underwater wet arc welds were experimentally performed on 11mm thick SS400 mild steel plate as base metal by using six different types of flux coated electrodes of 4.0mm diameter; KSKR, KSKT, USBL, JPUW, UWEA, and UWEB. As results, the developed flux coated underwater electrode had a good weldability compared with other domestic terrestrial electrodes. By rapid cooling rate, the hardness value of HAZ were increased by quenching effects. Mechanical properties for the multi-pass butt-welding specimen are also tested experimentally. The feasibility of the developed underwater electrode was experimentally studied and the results achieved in this wet arc welds have shown that the developed wet welding electrode UWEB can have a degree of integrity.

  • PDF

Relative Measurement of Differential Electrode Impedance for Home Healthcare Device (Home Healthcare 장치를 위한 차동 전극 임피던스의 상대적인 측정)

  • Woo, Y.J.;Yoo, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.469-470
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

  • PDF

Optimized electrode design to improve transmittance in the Patterned Vertical Alignment Liquid Crystal Display

  • Hwang, Seong-Jin;Kim, Youn-Sik;Lee, Seung-Hee;Lyu, Jae-Jin;Kim, Kyeong-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.549-552
    • /
    • 2007
  • Patterned vertical alignment (PVA) mode requires multi-domain to exhibit wide viewing angle whereas the transmittance is sacrificed. To overcome the demerit, a fine pattern was formed at folded region in PVA Z-shape electrode structure. In the present work fine patterns were formed near domain boundary regions where the unwanted field direction which causes the LC to tilt down in unwanted direction exists. Thereby transmittance is improved near those fine patterns. This method is very simple and more cost-effective process than the other methods. In this article, we show the method of fine pattern formation and its influence on LC molecule in PVA mode with Z-shape electrode structure.

  • PDF

Electrical insulation characteristics with simulated electrode system of HTS (HTS pancake 코일을 모의한 전극계에서의 전기절연 특성)

  • Joung, Jong-Man;Baek, Seung-Myeong;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.58-63
    • /
    • 2002
  • For the experiment the four types of spacer were distinguished by arrangement. The flashover characteristic on each types of spacer was investigated and the flashover phenomena were observed to understand breakdown mechanism in liquid nitrogen($LN_{2}$). The spacer should be placed interior coil as an insulator, a cooling channel and s supporter of structures. The simulated electrode used in the experiment was made from five turns of HTS tape. Experimental results revealed that multi-layer and barrier effects did work well in Air but did not in $LN_{2}$. These result suggested that the flashover in LN2 caused by the bubbles due to partial discharge at micro gap, g. The flashover characteristics decreased to 70% when g is 0.2 mm. The degradation was improved by even treatment on surface of coil electrode.

  • PDF