• 제목/요약/키워드: multi-discharge

검색결과 360건 처리시간 0.031초

자계하의 DC 코로나 방전에 의한 NOx 제거 (NOx Removal Using DC Corona Discharge Under Magetic Field)

  • 김건호;김종달;이덕출;고희석;박재윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.462-464
    • /
    • 1995
  • In this paper, experiments were carried out to study the decrease of NOx in simulated flue gases (initial concentration of NO 1000, 750, 400 ppm, : $N_2$ balance gas). Characteristics of NOx reduction are measured and analysed in corona discharge of multi needles to plane electrode structure and magnetic field. The best characteristics of NO reduction is measured when electric and magnetic field were supplied to reactor, at same time. Consumption power applied electric and magnetic field were higher than that of discharge applied only electric field.

  • PDF

웨이블렛 변환을 이용한 부분 방전 신호 분석 (An Analysis of Partial Discharge signal Using Wavelet Transforms)

  • 박재준;장진강;임윤석;심종탁;김재환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 1999
  • Recently, the wavelet transform has been a new and powerful tool for signal processing. It is more suitable specially for the feature extraction and detection of non-stationary signals than traditional methods such as, the Fourier Transform(FT), the Fast Fourier Transform(FFT) and the Least Square Method etc. because of the characteristic of the multi-scale analysis and time-frequency domain localization. The wavelet transform has been developed for the analysis of PD pulse signal to raise in the progress of insulation degradation. In this paper, the wavelet transform was applied to one foundational method for feature extraction. For the obtain experimental data, a computer-aided partial discharge measurement system with a single acoustic sensor was used. If we are applying to the neural network method the accumulated data through the extracted feature, it is expected that we can detect the PD pulse signal in the insulation materials on the on-line.

  • PDF

댐 설계홍수량 산정방법에 관한 연구 (Study on the Calculation Method of Design Flood Discharge of Dam)

  • 이재홍;문영일;백유현;장광진
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.277-281
    • /
    • 2011
  • 본 연구에서는 국내의 다목적 댐 전체를 대상으로 강우-유출 모형에 의한 과거의 홍수량 산정방식과 최근의 홍수량 산정방식을 유역 면적 규모별로 분류하여 비교 분석하였다. 홍수량에 영향을 미치는 기본인자로 강우량, 강우의 시간분포, 유효우량 산정방법(손실분석), 강우-유출 모형, 매개 변수 추정 및 기저유량 등을 선정하여 각 인자별 민감도 분석을 수행함으로써 홍수량에 미치는 영향을 정량적으로 분석하였다. 분석결과 최근의 방법으로 산정한 홍수량과 과거의 방법으로 산정한 홍수량이 유역면적 규모에 따라 다양한 변동폭으로 증가하거나 감소하였는데, 강우의 시간분포 변경이 홍수량을 감소시키는 원인으로 분석되었고, 최근 기상이변에 의한 강우량의 증가와 단위도의 매개변수 추정방법의 변경이 홍수량을 증가시키는 가장 큰 원인으로 분석되었다.

  • PDF

Modified Gas-jet Boosted Radio-frequency Glow Discharge 셀의 개발 및 최적화에 관한 연구 (Study for Conductive and Non-conductive Multi-layers Depth Profiling Analysis of Radio Frequency Gas-jet Boosted Glow Discharge Spectrometry)

  • 조원보;스튜어드 보든;정종필;강원규;김규환;김효진
    • 분석과학
    • /
    • 제15권2호
    • /
    • pp.108-114
    • /
    • 2002
  • 고체 시료를 직접 분석하기 위하여 글로우 방전 원자 방출법을 이용한 새로운 장치를 개발하였다. 이 시스템은 기존의 gas-jet boosted nozzle을 개선한 새로운 방전 셀과 Radio-frequency 전원장치를 사용하였다. 기존의 gas-jet boosted nozzle의 경우 재침전이 적고, 시료 손실량이 많아서 낮은 방전 전력에서 저 합금강의 미량 분석에 적합하였다. 하지만 높은 방전 전력을 사용할 경우 시료 손실량이 많아지고, 재석출(redeposition)이 증가함으로 해서 플라스마가 불안정해지는 단점을 지니고 있었다. 기존의 글로우 방전 셀의 경우 방전 전력을 높일 수록 플라스마의 들뜸 온도가 증가하는 경향을 가진다. 이 때문에 높은 방전 전력에서는 플라스마의 온도가 높아져서 극미량 분석이 가능할 수 있지만, 기존의 노즐 부분에 문제점으로 인해 높은 방전 전력으로 분석하기에는 부적합하였다. 이러한 문제점을 modified gas-jet boosted nozzle은 시료 손실량이 같은 방전 전력에서 기존의 가스 제트 흐름노즐에 비하여 감소하지만 높은 방전 전력에서는 플라스마 안정도가 증가하여 극미량 분석이 가능하도록 개선하였다. 본 시스템은 여러 가지 방전에 미치는 실험 변수인 압력과 가스 흐름량 그리고 방전 전력의 변화에 따른 시료 손실 속도와 방출 세기 등의 변화를 측정하여 최적화 하였으며, 표준 시료 Fe합금을 이용하여서 미량 분석을 하였다.

제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식 (High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method)

  • 정재철;서인우;오병주;황기웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

웨이블렛-신경망을 이용한 부분방전 종류와 진단에 관한연구 (A Study on Diagnosis of Partial Discharge Type Using Wavelet Transform-Neural Network)

  • 박재준;전현구;전병훈;김성홍;권동진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.894-899
    • /
    • 2002
  • In this papers, we proposed the new method in order to diagnosis partial discharge type of transformers. For wavelet transform, Daubechies filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about high frequency current signal per 3-electrode type (needle-plane electrode, IEC electrode and Void electrode.). Also. these coefficients are used to identify Signal of internal partial discharge in transformer. As a result. from compare of high frequency current signal amplitude and average value. we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise. In case of skewness and kurtosis, we are obtained results of Void electrode> IEC electrode > Needle-Plane electrode. As Improved method in order to diagnosis partial discharge type of transformers, we use neural network.

  • PDF

GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구 (A Comparate Study for the PD Pattern Analysis using Different Type of Sensors Applicable to the On-line Monitoring of GIS)

  • 구자윤;장용무;최재옥;연만승;이지철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.198-205
    • /
    • 2005
  • Many precedent investigations hate been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of tile plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by tee different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects tinder investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.

고압전동기 고정자권선의 절연결함에 대한 특징추출기법 (Feature Extraction Technique for Insulation Fault of High Voltage Motor Stator Winding)

  • 박재준;이성룡;문대철
    • 한국전기전자재료학회논문지
    • /
    • 제19권10호
    • /
    • pp.976-983
    • /
    • 2006
  • Multi-resolution Signal Decomposition (MSD) Technique of Wavelet Transform has interesting properties of capturing the embedded horizontal, vertical and diagonal variations within an image in a separable form. This feature was exploited to identify individual partial discharge sources present in multi-source PD pattern, usually encountered during practical PD measurement. Employing the Daubechies wavelet, feature were extracted from the third level decomposed and reconstructed horizontal and vertical component images. These features were found to contain the necessary discriminating information corresponding to the individual PD sources and multi-PD soruces.

Multi-hole 전극에 의한 Ed-Drilling 가공성 향상 (Improvement of the ED-Drilling Machinability using Multi-hole Electrodes)

  • 김창호
    • 한국기계가공학회지
    • /
    • 제11권5호
    • /
    • pp.88-93
    • /
    • 2012
  • This paper describes the machinability of the sintered carbide and tool-die steel(STD-11) by electric discharge drilling with various tubular electrodes which have multi-holes. Various types of electrode which have different diameters and materials are used with the application of continuous direct current and axial electrode feed. Inner part of electrodes are inserted with smaller tubes or Y-channel or bar. In ED-Drilling, the dielectric flushed down the interior of the rotating tube electrode, in order to remove machining debris from the hole. As result of experiments, the bigger the diameter of the electrode is, the lower the material removal rate is. Machinability of copper electrode is higher than that of brass. In machining of sintered carbide, to use oil is better than distilled water as dielectric.

멀티에어컨의 성능해석 프로그램 개발 (Development of Simulation Program for Multi-Air conditioner)

  • 정백영;고재윤;박병덕;임장순
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.63-72
    • /
    • 2000
  • In this study, theoretical simulation method for the steady state characteristics of a refrigeration cycle which consists of one condenser and multi-evaporator (Multi-air conditioner) is presented. The simulation was performed for a typical multi-air conditioning system consisted one outdoor unit with air-cooled condenser, compressor, linear electric expansion valve and bypass circuit and connected three-evaporators (three indoor units). The simulation results are good agreement with those of experiments within 5 $\sim$ 10% at the given system operation conditions which are condensing pressure, evaporating pressure, sub-cooled degree of condenser, superheated degree, discharge temperature of compressor and pulse of linear electric expansion valve.

  • PDF