• 제목/요약/키워드: multi-cavity mold

검색결과 65건 처리시간 0.033초

편측 분기형 러너 배열을 가진 다수 캐비티 사출금형에서의 충전 불균형도 (The Filling Imbalance in Multi-Cavity Injection Molds with Unary Branch Type Runner Lay-out)

  • 강철민;정영득
    • 소성∙가공
    • /
    • 제13권7호
    • /
    • pp.580-585
    • /
    • 2004
  • Almost all injection molds have multi-cavity runner system fur productivity and are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, filling imbalances have been observed though geometrically balanced runner lay-out. Generally, these filling imbalances are due to thermal unbalance, viscosity, characteristic of polymers and so on. These kinds of filling imbalances have already been reported by Beaumont since 1997, but his research has mainly focused on filling imbalance at binary runner. In this study, we conducted an experimental study about the filling imbalances in unary branch runner as well as binary branch runner and inquired into the causes of filling imbalances. The results could be summarized as fellowing: Filling imbalances existed in multi-cavity mold with unary branch runner, it could be decreased by optimizing processing condition such as increasing injection rate, and it is almost proportion to each polymer's temperature sensibility.

사출금형의 러너시스템 형상에 따른 균형 충전도 (Degree of Filling Balance according to Runner Shapes in Injection Mold)

  • 한동엽;정영득
    • Design & Manufacturing
    • /
    • 제6권1호
    • /
    • pp.52-57
    • /
    • 2012
  • Aspect of filling imbalance that is originated from imbalanced share rate in runner is changed by material property, runner layout that are factors of changing viscosity and by injection pressure, injection speed, melt temperature and mold temperature that are injection conditions. In this paper, we made a study of runner system that is one of factor of filling imbalance and Sharp Conner Effect and Groove Corner Effect that are recently released. The study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Also, we suggested runner system for filling imbalance by adapting the two effects at multi cavity of unary branch type and theoretical investigated flow in the Shrap Conner runner type.

  • PDF

사출성형해석 연구를 이용한 게이트 밸런스 계산식의 검증 (Verification of gate balancing equation using injection molding analysis)

  • 한성렬
    • Design & Manufacturing
    • /
    • 제12권3호
    • /
    • pp.55-59
    • /
    • 2018
  • In a multi-cavity mold having a runner layout of a fish bone structure, problems of unbalanced filling between cavities occur constantly. Unbalanced charging lowers the dimensional accuracy of a molded article and causes deformation after molding. To solve this problem, the gate size connected to each cavity is adjusted using the BGV (Balanced Gate Value) equation. In this paper, in order to solve the filling imbalance problem of the runner layout mold of fish bone structure through injection molding analysis study, we compared the charging imbalance phenomenon before and after improvement after adjusting the gate size by applying BGV equation. From the results of the molding analysis, the shrinkage ratio before and after the improvement of the molded article was improved by only about 0.08%. Based on these results, it was confirmed that the charging imbalance problem was not significantly improved even when the BGV equation was applied.

사출성형 해석과 선호함수법에 기초한 자동차 TCU 커넥터 커버의 금형 레이아웃 및 보압의 최적 설계 (Optimal Design of Mold Layout and Packing Pressure for Automobile TCU Connector Cover Based on Injection Molding Analysis and Desirability Function Method)

  • 박종천;유만준
    • 한국기계가공학회지
    • /
    • 제19권9호
    • /
    • pp.1-8
    • /
    • 2020
  • In this study, the optimal design of the multi-cavity mold layout and packing pressure for the automobile TCU connector cover is determined based on the injection molding analysis and the desirability function method for multi-characteristic optimization. The design characteristics to be optimized are the warpage and sink marks of the product, the scrap of the feed system, and the clamping force. The optimal design is determined by performing injection molding analysis and desirability analysis for design alternatives defined by a complete combination of five mold layouts and six-level packing pressure. The optimal design shows that the desirability values for individual characteristics are quite high and balanced, and the resulting values of individual characteristics are satisfactorily low.

새로운 3D 멧싱 기법으로 충전 불균형을 예측할 수 있는 사출성형 CAE 활용 (Injection Molding 3D CAE Applications for Estimating Filling Imbalance Using a New Runner system meshing)

  • 고승우;정수정;서상훈;정영득
    • Design & Manufacturing
    • /
    • 제6권2호
    • /
    • pp.31-36
    • /
    • 2012
  • Now days CAE has been used for almost all injection molding designs in order to find the best injection conditions. Almost all CAE use 2-D mesh, but the CAE with 2-D mesh can't indicate such as jetting, flow-mark and filling imbalance in multi cavity mold. In this study, we suggested a new 3D meshing. the method which can indicate the filling imbalance in geometrically balanced runner system with Mold Flow MPI 6.1 and we found out that the calculation times are saved. As a feasibility study, we verified that Melt Flipper, RC Pin etc appeared the balanced filling behaviors. of geometrically balanced runner system and Melt Flipper, filling imbalance was indicated more accurately.

  • PDF

균형충전을 위한 HR3P 금형 구조에서의 공정의 최적화 (Optimization of Processing on Filling Balance of the HR3P Mold Structure)

  • 권윤숙;정영득
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.98-102
    • /
    • 2009
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance has been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and polymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system. The filling imbalance was decreased up to result range of $3{\leq}DFI{\leq}8(%)$ by using a new runner system for balanced filling.

분말사출성형을 이용한 다수 캐비티 치과용 요오드 용기 금형제작에 관한 연구 (A Study on mold manufacture of multi-cavity dental iodine container using powder injection molding)

  • 최재훈
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.21-26
    • /
    • 2014
  • 치과에서 사용되는 구강 치료용 요오드 용기는 개폐 시 용기의 캡에 부착되어 있는 칼날에 의해 치료용 실은 절단이 된다. 금속의 칼날은 요오드 용액과 반응하여 단기간에 부식이 되는 문제로 인해 환자의 위생에도 영향을 준다. 이러한 문제를 해결하기 위해 최근 세라믹 칼날로 대체되어진 제품들도 개발되어 생산되는데, 이때 세라믹 칼날은 수작업과 기계가공을 통해 만들어 진다. 본 연구에서는 세라믹 칼날을 분말사출성형공정으로 대량 생산할 수 있도록 20Cavity의 균일 충전을 위한 유동 시스템을 제안하였다. Moldflow를 이용하여 20cavity 유동성에 대한 시뮬레이션을 진행하였고, 금형제작과 수정을 통해 금형을 완성하였다. 사출성형 후 탈지와 소결공정을 통해 완성하고, 금형에 세라믹 칼날을 인서트 사출하여 캡 제품을 완성하였다. 본 연구를 통해 유효한 절단 성능을 갖는 세라믹칼날 대량생산 가능성을 검증하였다.

새로운 3D 멧싱 기법으로 충전 불균형을 예측할수 있는 사출성형 CAE 활용 (Injection Molding 3D CAE Applications for Estimating Filling Imbalance Using a New Runner system meshing)

  • 고승우;정수정;서상훈;정영득
    • 한국금형공학회:학술대회논문집
    • /
    • 한국금형공학회 2008년도 하계 학술대회
    • /
    • pp.121-127
    • /
    • 2008
  • Nowdays CAE has been used for almost all injection molding designs in order to find the best injection conditions. Almost all CAE use 2-D mesh, but the CAE with 2-D mesh can't indicate such as jetting, flow-mark and filling imbalance in multi cavity mold. In this study, we suggested a new 3D meshing. the method which can indicate the filling imbalance in geometrically balanced runner system with Mold Flow MPI 6.1 and we found out that the calculation times are saved. As a feasibility study, we verified that Melt Flipper, RC Pin etc appeared the balanced filling behaviors. of geometrically balanced runner system and Melt Flipper, filling imbalance was indicated more accurately.

  • PDF