• Title/Summary/Keyword: multi-cable

Search Result 281, Processing Time 0.03 seconds

Power Performance Comparison using Dimming in the Indoor Multi-hop VLC Environment (실내 멀티홉 VLC환경에서 디밍을 적용한 파워 성능 비교)

  • Kim, Joo-Seok;Lee, Min-Jung;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.71-78
    • /
    • 2017
  • Visible light communication (VLC) offers communication function in addition to illumination. Because the signal communication capacity per cable is 1,000 times compared to the power line communication (PLC), optical fiber is being advertised as the basis of the information and communication. Also dimming control of LED is an important component needed to provide energy savings and quality of life. This study configured multi-hop VLC system model in a building using optical fiber and analyzed the power performance of two of modulations using dimming techniques. The transmission power and received power were used to compare the power performance in multi-hop VLC environments.

An Effective Multi-hop Relay Algorithm in Wireless Mesh Network (무선 메쉬 네트워크 환경에서 효율적인 다중 홉 전달 기법)

  • Kim, Young-An;Park, Chul-Hyun;Hong, Choong-Seon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10B
    • /
    • pp.872-882
    • /
    • 2006
  • The Wireless Mesh Network uses a wireless communication technology with transmission rates similar to that of a cable, which is used as a backbone network. The topology structure is in a Mesh form which resembles an Ad-hoc network, however a metric is needed in order to set the channel and channel methods since the operation intentions and interior motions are different. This thesis proposes a metric(ETR : Expected Transmission Rate) that sets the channel with physical link performance and multi hop transmission capabilities. This metric will also be based on multi channel creation methods and Hop-by-hop routing techniques for an effective multi hop transmission with no loops.

Wireless sensor network design for large-scale infrastructures health monitoring with optimal information-lifespan tradeoff

  • Xiao-Han, Hao;Sin-Chi, Kuok;Ka-Veng, Yuen
    • Smart Structures and Systems
    • /
    • v.30 no.6
    • /
    • pp.583-599
    • /
    • 2022
  • In this paper, a multi-objective wireless sensor network configuration optimization method is proposed. The proposed method aims to determine the optimal information and lifespan wireless sensor network for structural health monitoring of large-scale infrastructures. In particular, cluster-based wireless sensor networks with multi-type of sensors are considered. To optimize the lifetime of the wireless sensor network, a cluster-based network optimization algorithm that optimizes the arrangement of cluster heads and base station is developed. On the other hand, based on the Bayesian inference, the uncertainty of the estimated parameters can be quantified. The coefficient of variance of the estimated parameters can be obtained, which is utilized as a holistic measure to evaluate the estimation accuracy of sensor configurations with multi-type of sensors. The proposed method provides the optimal wireless sensor network configuration that satisfies the required estimation accuracy with the longest lifetime. The proposed method is illustrated by designing the optimal wireless sensor network configuration of a cable-stayed bridge and a space truss.

Magnetic Fields Reduction Characteristics of Multi-layer Shielding Wear for a Worker Using AC Arc Welder (교류 아크용접기를 사용하는 작업자의 이중 차폐복 자계저감 특성검토)

  • Min, Suk-Won;Park, Jun-Hyeong;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1465_1466
    • /
    • 2009
  • Power cable of an AC arc welder can surround a body of worker at the moment of welding. Applying the boundary element method, we calculated current densities induced in organs inside a worker in case he weared a multi-layer shielding cloth. We know these were lowest when high permeability materials such as silicon and permalloy were applied to the interior of a suit and high conductivity materials such as copper were to the exterior.

  • PDF

Wavelength and Waveband Assignment for Ring Networks Based on Parallel Multi-granularity Hierarchical OADMs

  • Qi, Yongmin;Su, Yikai;Jin, Yaohui;Hu, Weisheng;Zhu, Yi;Zhang, Yi
    • ETRI Journal
    • /
    • v.28 no.5
    • /
    • pp.631-637
    • /
    • 2006
  • In this paper we study the optimization issues of ring networks employing novel parallel multi-granularity hierarchical optical add-drop multiplexers (OADMs). In particular, we attempt to minimize the number of control elements for the off-line case. We present an integer linear programming formulation to obtain the lower bound in optimization, and propose an efficient heuristic algorithm called global bandwidth resource assignment that is suitable for the design of large-scale OADM networks.

  • PDF

The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line (지중배전선로의 다회로차단기 운영방안 연구)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.4
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

The Crack Resistance and the Dielectric Breakdown properties of Epoxy Composities due to the Multi Stresses Variation (다중 응력 변화에 따른 에폭시 복합체의 내크랙성 및 절연 파괴 특성)

  • 송봉철;김상걸;안준호;김충혁;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.136-139
    • /
    • 2000
  • Epoxy materials are used as insulation material for electric power cables. In the case of a flow of excess current due to the temperature difference which occurs between the heat of the conductor and the atmosphere, heat degrades connection point of the cables. Also, the mechanical stress, which occurs due to the thermal expansion coefficient of cable connection electrode system and epoxy insulation materials along with the gap between thermal conduction based on the extra high voltage of transmitted voltage, increases possibility of cracks to occur. The relationship between mechanical stress and electrical breakdown mechanism is verified for the epoxy materials such as high toughness epoxy materials, which comes to be used contemporarily, and for the breakdown mechanism of epoxy materials on the multi-stresses (mechanical and electrical) due to the variation of the temperature.

  • PDF

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

The Study on the Introduction of Clear QAM and 8VSB in the Digital Conversion of Pay TV (유료방송 디지털 전환에서 클리어 쾀과 8VSB 도입에 관한 연구)

  • Kim, Hee-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.23-34
    • /
    • 2013
  • This study would verify the validity of two transmission technology, 'Clear QAM' and '8VSB'. 'Clear QAM' and '8VSB', the transmisson technology, have been suggested as the concrete alternatives in the situation that half of subscriber of multi channel tv service have been still out of benefit from digital convert. In this study, we have shown that the introduction of 'Clear QAM' and '8VSB' should ease economical burdens and information minority group without extra set-top box. But there is another concern that it should negatively affect on the contents industry by a devaluation of the multi channel tv service or by an infringement of copyright. In these reasons, it is still difficult to solve the related concern, though the government have to set up the politic goal for the related industry as well digital convert. This study suggested that Korea Communication Commission consider above-mentioned technology temporarily, and reconsider 'Clear QAM' around the completion of the digital convert project.

Preparation of conductive EPDM rubber sheets by electroless Ni-plating for electromagnetic interference shielding applications (무전해 Ni 도금법을 이용한 전자파 차폐용 도전성 EPDM 고무의 제조)

  • Lee, Byeong Woo;Cho, Soo Jin;Yang, Jun Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.5
    • /
    • pp.193-198
    • /
    • 2015
  • In the study, electroless Ni-plating on flexible ethylene-propylene-diene-monomer (EPDM) rubber sheets for the application of an insert block for shielding electromagnetic interference of multi cable transit (MCT) systems was investigated. Ni crystallinity and adhesion have been found to vary with processing parameters such as pH and temperature of the plating bath. It was shown that Ni-films having the high crystallinity and optimum electric conductivity were obtained on EPDM rubber sheets under pH 7 and 8 at $60{\sim}70^{\circ}C$. The conductive Ni-plated EPDM rubber prepared at pH 7 at $70^{\circ}C$ showed the enhanced adhesion and electric conductivity, and the high electromagnetic interference shielding effect in the 400 MHz~1 GHz range.