• Title/Summary/Keyword: motor ability

Search Result 528, Processing Time 0.026 seconds

The Effect of Glide Path on Canal Centering Ability in Reciprocating File System (Reciprocating 파일 시스템에서 Glide Path가 근관만곡도 유지에 미치는 영향)

  • Zang, Ki-Choul;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.245-252
    • /
    • 2012
  • The purpose of this study was to evaluate the influence of glide path on canal centering ratio after instrumentation with different single file systems; WaveOne and Reciproc. Reciproc R25 (VDW), WaveOne Primary (Dentsply Maillefer) and PathFile #13, 16, 19 (Dentsply Maillefer) were used in this study. In no glide path groups, Reciproc files and WaveOne files used for canal preparation without glide path. In glide path groups, the PathFile were used before canal preparation. Methylene blue dye was introduced into the canal to obtain a clear pre-instrumentation image. Pre-instrumentation images and post-instrumentation images were scanned using Epson Perfection V700 Photo scanner (Epson, Nagano, Japan). Transparencies of post-instrumentation images were changed and superimposed on pre-instrumentation images using Adobe Photoshop CS 3 (Adobe Systems Incorporated, San Jose, CA, USA). The centering ratio was calculated for each instrumented canal using the following formula: CR=|X1-X2|/Y. It was statistically analyzed using two-way ANOVA at 95% confidential level. The centering ratio in glide path groups were significant less than it in no glide path groups at 3, 4, 5 and 6 mm level. Except 1 and 6 mm level, WaveOne groups had significant less centering ration than Reciproc groups. At 6 mm level, there was no significant difference between WaveOne and Reciproc. In the limitation of this study, creation of a previous glide path before reciprocating motion instrumentation in curved canal appears to be appropriate and WaveOne system can be used for preparation of curved canal without severe aberrations.

COMPARISON OF DEVELOPMENTAL AND PSYCHOPATHOLOGlCAL CHARACTERISTICS FOR RAD AND PDD CHILDREN (반응성 애착장애 아동과 전반적 발달장애 아동의 발달 및 정신병리학적 특징의 비교연구)

  • Yoon, Hyun-Sook;Choi, Jin-Sook;Kim, Tae-Ryeon;Hong, Kang-E
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.3-13
    • /
    • 1992
  • For the purpose of better understanding of RAD children, comparisons were performed about the developmental and psychopathological characteristics between RAD and PDD children. Study subjects were the children between the ages 2 and 6. who visitied SNUCH Child and Adolescent Psychiatry OPD or treated in Day Treatment Center during May, 1989 and Sep., 1991, diagnosed by the child psychiatrist as RAD or PDD according to DSM-III-R diagnostic criteria. A total of 40 children were included in the study. 20 were RAD(18 boys, 2 girls). 20 were PDD(20 boys). PEP was performed to all study subjects, by the raters blind to psychiatric diagnosis of each. And analysis was done about the level of developmental functioning score and psychopathological scores between RAD and PDD children. The results are as follows 'There were retardation on the general developmental functioning in RAD children, and the severity of retardation were lined up as perceptual ability>imitation>gross motor>cogitive language>eye-hand coordination>fine motor. Characteristics of psychopathology in RAD children were lined up by severity as language>play>relationship>affection >sensory. Group differences of the two shows on PDD group rejection score was significantly higher on the perception item. while RAD was superior on the perception emerging response. Differences of the psychopathology between two groups were on such areas as ; Affection, which was significantly higher on 'Absent' in RAD, while significantly higher on 'severe' in PDD children. On the interest for the play and materials. sensory and language areas, RAD children were significantly higher ratings on 'Absent' than PDD children.

  • PDF

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file (Mtwo 전동 파일을 사용한 single length technique과 crown-down technique의 근관성형 효율 비교)

  • Lim, Yoo-Kyoung;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.385-396
    • /
    • 2007
  • The aims of this study were to compare the shaping effect and safety between single length technique recommended by manufacturer and crown-down technique using Mtwo rotary file and to present a modified method in use of Mtwo file. Sixty simulated root canal resin blocks were used. The canals were divided into three groups according to instrument and the manner of using methods. Each group had 20 specimens. Group MT was instrumented with single length technique of Mtwo, group MC was instrumented with crown-down technique of Mtwo and group PT was instrumented with crown-down technique of ProTaper. All of the rotary files used in this study were operated by an electric motor. The scanned canal images of before and after preparation were superimposed. These superimposed images were evaluated at apical 1 to 8 mm levels Angle changes were calculated. The preparation time, weight loss, instrument failure and binding, canal aberrations, and centering ratio were measured. Statistical analysis of the three experimental groups was performed with ANOVA and Duncan's multiple range tests for post-hoc comparison and Fisher's exact test was done for the frequency comparison. In total preparation time, group MT and group MC were less than group PT. In the aberrations, group MT had more elbows than those of group MC and group PT. The binding of group MC was least and group MT was less than group PT (P < 0.05). Under the condition of this study, crown-down technique using Mtwo rotary file is better and safer method than single length technique recommended by the manufacturer.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

Implementation of a Self Controlled Mobile Robot with Intelligence to Recognize Obstacles (장애물 인식 지능을 갖춘 자율 이동로봇의 구현)

  • 류한성;최중경
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.312-321
    • /
    • 2003
  • In this paper, we implement robot which are ability to recognize obstacles and moving automatically to destination. we present two results in this paper; hardware implementation of image processing board and software implementation of visual feedback algorithm for a self-controlled robot. In the first part, the mobile robot depends on commands from a control board which is doing image processing part. We have studied the self controlled mobile robot system equipped with a CCD camera for a long time. This robot system consists of a image processing board implemented with DSPs, a stepping motor, a CCD camera. We will propose an algorithm in which commands are delivered for the robot to move in the planned path. The distance that the robot is supposed to move is calculated on the basis of the absolute coordinate and the coordinate of the target spot. And the image signal acquired by the CCD camera mounted on the robot is captured at every sampling time in order for the robot to automatically avoid the obstacle and finally to reach the destination. The image processing board consists of DSP (TMS320VC33), ADV611, SAA7111, ADV7l76A, CPLD(EPM7256ATC144), and SRAM memories. In the second part, the visual feedback control has two types of vision algorithms: obstacle avoidance and path planning. The first algorithm is cell, part of the image divided by blob analysis. We will do image preprocessing to improve the input image. This image preprocessing consists of filtering, edge detection, NOR converting, and threshold-ing. This major image processing includes labeling, segmentation, and pixel density calculation. In the second algorithm, after an image frame went through preprocessing (edge detection, converting, thresholding), the histogram is measured vertically (the y-axis direction). Then, the binary histogram of the image shows waveforms with only black and white variations. Here we use the fact that since obstacles appear as sectional diagrams as if they were walls, there is no variation in the histogram. The intensities of the line histogram are measured as vertically at intervals of 20 pixels. So, we can find uniform and nonuniform regions of the waveforms and define the period of uniform waveforms as an obstacle region. We can see that the algorithm is very useful for the robot to move avoiding obstacles.

A Systematic Review on the Effects of Virtual reality-based Telerehabilitation for Stroke Patients (뇌졸중 환자를 위한 가상현실 기반의 원격재활 효과에 관한 체계적 고찰)

  • Lim, Young-Myoung;Lee, ji-Yong;Jo, Seong-Jun;Ahn, Ye-Seul;Yoo, Doo-Han
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.7 no.1
    • /
    • pp.59-70
    • /
    • 2017
  • Objective : The purpose of this study was to examine the effect of virtual reality-based remote rehabilitation on stroke patients systematically and to look for its effect and how to apply it domestically. Methods : In order to search data, EMBASE and CINAHL database were used. Relevant research used those terms of virtual reality, telerehabilitation, and stroke. A total of 10 studies satisfying the selection criteria was analyzed according to their qualitative level, general characteristics, and PICO method. Results : Based on the selected 10 studies, virtual reality-based telerehabilitation system was applied. Sensory and motor feedback was provided with inputting visual and auditory senses through a video in the home environment, and it stimulated changes in the client's nervous system. Tools to measure the results were upper extremity function, balance and gait, activities of daily living, etc. Those virtual reality-based telerehabilitation method had an effect on upper extremity function and ability of sense of balance in all studies, and on the activities of daily living partially. Telerehabilitation service to make up environmental specificity improved satisfaction of client. That meaned the effect of the intervention to maintain the function. Conclusion : The virtual reality-based telerehabilitation system was applied to upper extremity function, sense of balance, and activities of daily living largely, and it showed that it helped to improve functions through intervention, supervision, and training of therapist in the home environment as well. This study suggests the basis and possibility of clinical application on virtual-reality based telerehabilitation. Additional research is needed to diverse virtual reality intervention methods and the effect of telerehabilitation in the future.

Effects of Tailored Occupational Activity Program applied to Patients with Dementia and Their Caregiver in Community (지역사회에 거주하는 치매환자와 보호자에게 적용한 맞춤형 작업 활동 프로그램의 효과)

  • Hwang, Yun-Jung;Lee, Kamg Sook;Lim, Hyun-Kook;Kim, Dai Jin;Jeong, Won-Mee
    • 한국노년학
    • /
    • v.31 no.1
    • /
    • pp.129-141
    • /
    • 2011
  • This study aims to find out effects of a tailored occupational activity program(TOAP) on the activities of daily living(ADL), cognitive function, depressive mood, and caregiver burden, who live in the community. Method : From October 2009 to May 2010, the TOAP was applied to 15 dementia patients and 15 of their caregivers, who was visitors of the Y-city Center for Managing Dementia in Gyunggi-do. The TOAP was designed for habituating patients and caregivers to the techniques acquired through goal activities and task and making it capable of being routinized regularly. The TOAP was applied to dementia patients and their cvaregivers twice a week for 7 weeks(one-time home visit, one-time phone inspection), a total of 14 times. Results: Significant differences among pre-test and post-test were found in the AMPS motor skills(1.10±1.14 and 1.34±1.2 respectively) scores, AMPS process skills(0.32±0.55 and 0.77±0.66 respectively) scores, ACL(3.86±0.65 and 4.17±0.64 respectively) scores, MMSE-KC(17.33±4.6 and 19.33±4.97 respectively) scores, GDS(11.73±6.87 and 8.53±7.09 respectively) scores, and caregiver burden(31.80±20.06 and 26.13±18.07 respectively) scores(p<0.05). A significant effect was confirmed from the TOAP which ADL, cognitive function, reduced patient's depression and caregiver burden(p<0.05). Conclusion: From the above results that a TOAP has an effect on the improvement of the ability to ADL, cognitive function and reduced depression and caregiver burden of dementia patients living in community. The present author hopes that, in the future, more diverse community based on tailored occupational activity programs will be developed to improve the functions of dementia patients living in community.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF