• Title/Summary/Keyword: motion blur

Search Result 116, Processing Time 0.024 seconds

Dual BTC Image Coding technique for Full HD Display Driver (Full HD 디스플레이 드라이버를 위한 Dual BTC 영상부호화 기법)

  • Kim, Jin-Hyung;Ko, Yun-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • LCD(Liquid Crystal Display) commonly used as an output device has a drawback of slow response time compared with CRT display. This drawback causes motion blur especially when an abrupt intensity change occurs in an image sequence as time goes on. To overcome the problem of slow response time overdriving technique has been used in TCON of LCD. In this technique, the previous frame data has to be compressed and stored in an external memory. Considering both chip size of TCON and computational complexity, AM-BTC has been applied to the 8bit HD display driver. However, the conventional method is not suitable for 10 bit Full HD because 10 bit Full HD data is much larger than that of 8 bit HD data. Being applied to 10 bit Full HD display driver, the conventional method increase cost by enlarging the external memory size of TCON or deteriorates image quality. In this paper, we propose dual BTC image coding technique for Full HD display driver that is an adaptive coding scheme according to morphological information of each sample block. Through experiments, it is verified that the proposed Dual BTC method performs better than the conventional method not only quantitatively but also qualitatively.

The Development of Image Processing System Using Area Camera for Feeding Lumber (영역카메라를 이용한 이송중인 제재목의 화상처리시스템 개발)

  • Kim, Byung Nam;Lee, Hyoung Woo;Kim, Kwang Mo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.37-47
    • /
    • 2009
  • For the inspection of wood, machine vision is the most common automated inspection method used at present. It is required to sort wood products by grade and to locate surface defects prior to cut-up. Many different sensing methods have been applied to inspection of wood including optical, ultrasonic, X-ray sensing in the wood industry. Nowadays the scanning system mainly employs CCD line-scan camera to meet the needs of accurate detection of lumber defects and real-time image processing. But this system needs exact feeding system and low deviation of lumber thickness. In this study low cost CCD area sensor was used for the development of image processing system for lumber being fed. When domestic red pine being fed on the conveyer belt, lumber images of irregular term of captured area were acquired because belt conveyor slipped between belt and roller. To overcome incorrect image merging by the unstable feeding speed of belt conveyor, it was applied template matching algorithm which was a measure of the similarity between the pattern of current image and the next one. Feeding the lumber over 13.8 m/min, general area sensor generates unreadable image pattern by the motion blur. The red channel of RGB filter showed a good performance for removing background of the green conveyor belt from merged image. Threshold value reduction method that was a image-based thresholding algorithm performed well for knot detection.

Modeling of Visual Attention Probability for Stereoscopic Videos and 3D Effect Estimation Based on Visual Attention (3차원 동영상의 시각 주의 확률 모델 도출 및 시각 주의 기반 입체감 추정)

  • Kim, Boeun;Song, Wonseok;Kim, Taejeong
    • Journal of KIISE
    • /
    • v.42 no.5
    • /
    • pp.609-620
    • /
    • 2015
  • Viewers of videos are likely to absorb more information from the part of the screen that attracts visual attention. This fact has led to the visual attention models that are being used in producing and evaluating videos. In this paper, we investigate the factors that are significant to visual attention and the mathematical form of the visual attention model. We then estimated the visual attention probability using the statistical design of experiments. The analysis of variance (ANOVA) verifies that the motion velocity, distance from the screen, and amount of defocus blur affect human visual attention significantly. Using the response surface modeling (RSM), we created a visual attention score model that concerns the three factors, from which we calculate the visual attention probabilities (VAPs) of image pixels. The VAPs are directly applied to existing gradient based 3D effect perception measurement. By giving weights according to our VAPs, our algorithm achieves more accurate measurement than the existing method. The performance of the proposed measurement is assessed by comparing them with subjective evaluation as well as with existing methods. The comparison verifies that the proposed measurement outperforms the existing ones.

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

A Study on Fast Iris Detection for Iris Recognition in Mobile Phone (휴대폰에서의 홍채인식을 위한 고속 홍채검출에 관한 연구)

  • Park Hyun-Ae;Park Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.2 s.308
    • /
    • pp.19-29
    • /
    • 2006
  • As the security of personal information is becoming more important in mobile phones, we are starting to apply iris recognition technology to these devices. In conventional iris recognition, magnified iris images are required. For that, it has been necessary to use large magnified zoom & focus lens camera to capture images, but due to the requirement about low size and cost of mobile phones, the zoom & focus lens are difficult to be used. However, with rapid developments and multimedia convergence trends in mobile phones, more and more companies have built mega-pixel cameras into their mobile phones. These devices make it possible to capture a magnified iris image without zoom & focus lens. Although facial images are captured far away from the user using a mega-pixel camera, the captured iris region possesses sufficient pixel information for iris recognition. However, in this case, the eye region should be detected for accurate iris recognition in facial images. So, we propose a new fast iris detection method, which is appropriate for mobile phones based on corneal specular reflection. To detect specular reflection robustly, we propose the theoretical background of estimating the size and brightness of specular reflection based on eye, camera and illuminator models. In addition, we use the successive On/Off scheme of the illuminator to detect the optical/motion blurring and sunlight effect on input image. Experimental results show that total processing time(detecting iris region) is on average 65ms on a Samsung SCH-S2300 (with 150MHz ARM 9 CPU) mobile phone. The rate of correct iris detection is 99% (about indoor images) and 98.5% (about outdoor images).

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF