• Title/Summary/Keyword: motion accuracy measurement

Search Result 192, Processing Time 0.032 seconds

Development of a Robotic System for Measuring Hole Displacement Using Contact-Type Displacement Sensors (접촉식 변위센서를 이용한 홀 변위 측정 로봇시스템 개발)

  • Kang, Hee-Jun;Kweon, Min-Ho;Suh, Young-Soo;Ro, Young-Shick
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.79-84
    • /
    • 2008
  • For the precision measurement of industrial products, the location of holes inside the products, if they exist, are often selected as feature points. The measurement of hole location would be performed by vision and laser-vision sensor. However, the usage of those sensors is limited in case of big change of light intensity and reflective shiny surface of the products. In order to overcome the difficulties, we have developed a hole displacement measuring device using contact-type displacement sensors (LVDTs). The developed measurement device attached to a robot measures small displacement of a hole by allowing its X-Y movement due to the contact forces between the hole and its own circular cone. The developed device consists of three plates which are connected in series for its own function. The first plate is used for the attachment to an industrial robot with ball-bush joints and springs. The second and third plates allow X-Y direction as LM guides. The bottom of the third plate is designed that various circular cones can be easily attached according to the shape of the hole. The developed system was implemented for its effectiveness that its measurement accuracy is less than 0.05mm.

Detection the Biomedical Information using the Piezo Film Sensor (Piezo Film Sensor를 이용한 생체 정보 검출)

  • Lee, H.W.;Seo, H.;Jeong, W.G.;Jang, D.B.;Lee, G.K.
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 2010
  • For the ubiquitous healthcare environment, real-time measurement of biomedical signals and accuracy of the measured biomedical information are very important. In addition, it is important to develop a healthcare device with low power In this paper, the synchronized pulse in a heartbeat was detected from the radial artery using the piezo film sensor, in order to eliminate inconvenience to wear a pulse detection finger probe. We can get a best output after applying the adaptive noise canceller using two piezo film sensor signals, pulse signal having motion artifacts and motion artifacts reference signal. To detect heartbeat, we use maximum point detection method from pulse removed motion artifacts.

  • PDF

Development of Start Feel Index of a Forklift Truck (지게차 출발감각 평가지수 개발)

  • Jang, Han-Gi;Guk, Du-Yun;Lee, Jong-Gyu;Choe, Jun-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.74-82
    • /
    • 2002
  • In this paper the start fuel index was developed to estimate ride quality of a forklift truck during the start motion. Through the consultation with test drivers, definition of start feel was made, and three parameters were selected to describe the start motion. They are engagement shock in the forwarding direction, vertical and pitch vibration respectively. To find out the relation between the measured motion and the subjective fueling, both the subjective rating and the measurement of vehicle motions were performed simultaneously. The correlation analysis between the two kinds of results showed start fuel was expressed by the measured accelerations with accuracy and reliability, Use of the new index has advantages of not only evaluating start fuel only by the measured signals but providing the consistent results which are not affected by physical and mental state of a test driver. Usefulness of the new index was confirmed by verification test on four new forklift trucks of a same model, which showed the order of preference by the index was coincided that by subjective evaluation.

Improved View-Based Navigation for Obstacle Avoidance using Ego-Motion

  • Hagiwara, Yoshinobu;Suzuki, Akimasa;Kim, Youngbok;Choi, Yongwoon
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.112-120
    • /
    • 2013
  • In this study, we propose an improved view-based navigation method for obstacle avoidance and evaluate the effectiveness of the method in real environments with real obstacles. The proposed method possesses the ability to estimate the position and rotation of a mobile robot, even if the mobile robot strays from a recording path for the purpose of avoiding obstacles. In order to achieve this, ego-motion estimation was incorporated into the existing view-based navigation system. The ego-motion is calculated from SURF points between a current view and a recorded view using a Kinect sensor. In conventional view-based navigation systems, it is difficult to generate alternate paths to avoid obstacles. The proposed method is anticipated to allow a mobile robot greater flexibility in path planning to avoid humans and objects expected in real environments. Based on experiments performed in an indoor environment using a mobile robot, we evaluated the measurement accuracy of the proposed method, and confirmed its feasibility for robot navigation in museums and shopping mall.

Validity of a Portable APDM Inertial Sensor System for Stride Time and Stride Length during Treadmill Walking

  • Tack, Gye Rae;Choi, Jin Seung
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • Objective: The purpose of this study was to compare the accuracy of stride time and stride length provided by a commercial APDM inertial sensor system (APDM) with the results of three dimensional motion capture system (3D motion) during treadmill walking. Method: Five healthy men participated in this experiment. All subjects walked on the treadmill for 3 minutes at their preferred walking speed. The 3D motion and the APDM were simultaneously used for extracting gait variables such as stride time and stride length. Mean difference and root mean squared (RMS) difference were used to compare the measured gait variables from the two measurement devices. The regression equation derived from the range of motion of the lower limb was also applied to correct the error of stride length. Results: The stride time extracted from the APDM was almost the same as that from the 3D motion (the mean difference and RMS difference were less than 0.0001 sec and 0.0085 sec, respectively). For stride length, mean difference and RMS difference were less than 0.1141 m and 0.1254 m, respectively. However, after correction of the stride length error using the derived regression equation, the mean difference and the RMS difference decreased to 0.0134 m and 0.0556 m or less, respectively. Conclusion: In this study, we confirmed the possibility of using the temporal variables provided from the APDM during treadmill walking. By applying the regression equation derived only from the range of motion provided by the APDM, the error of the spatial variable could be reduced. Although further studies are needed with additional subjects and various walking speeds, these results may provide the basic data necessary for using APDM in treadmill walking.

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

Development of a Squat Angle Measurement System using an Inertial Sensor (관성 센서기반 스쿼트 각도 측정 융합 시스템 개발)

  • Joo, Hyo-Sung;Woo, Ji-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.355-361
    • /
    • 2020
  • The squat is an exercise that can effectively improve the muscle strength of the lower body, which can be performed in a variety of places without restrictions on places including homes. However, injuries due to incorrect motion or excessive angles are frequently occurring. In this study, we developed a single sensor-based squat angle measurement system that can inform the squat angle according to the correct motion during the squat exercise. The sensor module, including the acceleration sensor and the gyro sensor, is attached to the user's thigh. The squat angle was calculated using the complementary filter complementing the pros and cons of acceleration and gyro sensor. It was found that the calculated squat angle showed the proper correlation compared to the squat angle measured by a goniometer, and the influence of the coefficient of the complementary filter on the accuracy was evaluated.

Development of a Smartphone Application for the Measurement of Tree Height and Diameter at Breast Height (수고 및 흉고직경 측정 스마트폰 애플리케이션 개발)

  • Kim, Dong-Hyeon;Kim, Sun-Jae;Sung, Eun-Ji;Kim, Dong-Geun
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.1
    • /
    • pp.72-81
    • /
    • 2021
  • We developed smartphone application and web application server to acquire and effectively manage tree measurement information. Smartphone applications can measure tree height, diameter at breast height (DBH), azimuth, altitude, slope, and positional coordinates using augmented reality (Google AR core) and motion sensors. The web application server effectively manages and stores measurement information. To evaluate the accuracy of information acquired using a smartphone, 90 Korean pine trees (Pinus koraiensis) were randomly selected from a natural mixed forest, with a total of 90 representative trees randomly collected from a natural mixed forest. Then, height and DBH were measured using a Haglof Vertex Laser Hypsometer and caliper. Comparisons of the results indicated significant results at the 95% level and a very high average correlation of 0.972 for both tree height and DBH. In terms of DBH, the average errors were 0.6745 cm and 1.0139 cm for artificial coniferous and natural mixed forests, respectively.

Attitude Estimation of Agricultural Unmanned Helicopters using Inertial Measurement Sensors (관성센서를 이용한 농용 무인 헬리콥터의 자세 추정)

  • Bae, Yeonghwan;Oh, Minseok;Koo, Young Mo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.32 no.3
    • /
    • pp.159-163
    • /
    • 2014
  • Agricultural unmanned helicopters have become a new paradigm for aerial application. Yet, such agricultural helicopters require easy and affordable attitude control systems. Therefore, this study presents an affordable attitude measurement system using a DCM (direction cosine matrix) algorithm that would be applied to agricultural unmanned helicopters. An IMU using a low-cost MEMS and an algorithm to estimate the attitude of the helicopter were applied in a gimbals structure to evaluate the accuracy of the attitude measurements. The estimation errors in the attitude were determined in comparison with the true angles determined by absolute position encoders. The DCM algorithm and sensors showed an accuracy of about 1.1% for the roll and pitch angle estimation. However, the accuracy of the yaw angle estimation at 3.7% was relatively larger. Such errors may be due to the magnetic field of the stepping motor and encoder system. Notwithstanding, since the intrinsic behavior of the agricultural helicopter remains steady, the determination of attitude would be reliable and practical.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.