• Title/Summary/Keyword: motion accuracy measurement

Search Result 192, Processing Time 0.035 seconds

Restoration of Realtime Three-Dimension Positions Using PSD Sensor (PSD센서를 이용한 실시간 3차원 위치의 복원)

  • Choi, Hun-Il;Jo, Yong-Jun;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.507-510
    • /
    • 2003
  • In this paper, optical sensor system using PSD(Position Sensitive Detection) is proposed to obtain the three dimensional position of moving markers attached to human body. To find the coordinates of an moving marrer with stereo vision system, two different sight rays of an moving marker are required. Usually, those are acquired with two optical sensors synchronized at the same time. PSD sensor is used to measure the position of an incidence light in real-time. To get the three-dimension position of light source on moving markers, a conventional camera calibration method are used. In this research, we realized a low cost motion capture system. The proposed system shows high three-dimension measurement accuracy and fast sampling frequency.

  • PDF

Blood Pressure Measurement using the Modified Step-wise Deflation Method (개선된 계단 배기 방법을 이용한 혈압 측정)

  • Oh, Hong-Sic;Lee, Jong-Shill;Chee, Young-Joon;Kim, In-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.351-358
    • /
    • 2010
  • In the automatic non-invasive blood pressure measurement device, the oscillometric method iswidely used. In the oscillometric method, the step-wise deflation has the advantage of the robustness for the motion artifacts than the linear deflation method. But it has the disadvantage of its longer measurement time because we need to detect two or more pulses in a certain cuff pressure step. In this study, we suggest the modified step-wise deflation method to overcome this limitation while maintaining the general concept of step-wise deflation. Using one valid pulse in each step and the deflating valve control during the diastolic period, the measurement time could be reduced. In order to verify the accuracy of the proposed algorithm, we compared the blood pressure values from the suggested method and the blood pressure values from the conventional auscultation method. The mean and standard deviation were -0.50${\pm}$5.3mmHg and 2.08${\pm}$4.75mmHg, for systolic and diastolic blood pressure respectively. The measurement time can be reduced up to the half of conventional step-wise deflation method.

Uncertainty Study of Added Resistance Experiment (부가저항 실험의 불확실성 연구)

  • Park, Dong-Min;Lee, Jaehoon;Kim, Yonghwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.5
    • /
    • pp.396-408
    • /
    • 2014
  • In this study, uncertainty analysis based on ITTC(International Towing Tank Conference) Recommended Procedures is carried out in the towing-tank experiment for motion responses and added resistance. The experiment was conducted for KVLCC2 model in head sea condition. The heave, pitch and added resistance were measured in different wave conditions, and the measurement was repeated up to maximum 15 times in each wave condition in order to observe the uncertainty of measured data. The uncertainty analysis was carried out by adopting the ISO-GUM(International Organization for Standardization, Guide to the Expression of Uncertainty in Measurements) method recommended by ITTC. This paper describes the details about the analysis method, uncertainty and the measured uncertainty for each source. The uncertainty analysis results are summarized as a tabular form. To validate the accuracy of the present measurement, the experimental results are compared with the results of numerical computation and other experiment. From the present uncertainty analysis, the main sources of uncertainty are identified, which can be very useful to improve the accuracy for added resistance experiment.

Localization of Mobile Robot Based on Radio Frequency Identification Devices (RFID를 이용한 이동로봇의 위치인식기술)

  • Lee Hyun-Jeong;Choi Kyu-Cheon;Lee Min-Cheol;Lee Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2006
  • Ubiquitous location based services, offer helpful services anytime and anywhere by using real-time location information of objects based on ubiquitous network. Particularly, autonomous mobile robots can be a solution for various applications related to ubiquitous location based services, e.g. in hospitals, for cleaning, at airports or railway stations. However, a meaningful and still unsolved problem for most applications is to develop a robust and cheap positioning system. A typical example of position measurements is dead reckoning that is well known for providing a good short-term accuracy, being inexpensive and allowing very high sampling rates. However, the measurement always has some accumulated errors because the fundamental idea of dead reckoning is the integration of incremental motion information over time. The other hand, a localization system using RFID offers absolute position of robots regardless of elapsed time. We construct an absolute positioning system based on RFID and investigate how localization technique can be enhanced by RFID through experiment to measure the location of a mobile robot. Tags are placed on the floor at 5cm intervals in the shape of square in an arbitrary space and the accuracy of position measurement is investigated . To reduce the error and the variation of error, a weighting function based on Gaussian function is used. Different weighting values are applied to position data of tags since weighting values follow Gaussian function.

High Precision Measurement for String Resonator used in FBG Strain Sensors (광섬유 브래그 격자 변형률 센서용 현공진기의 고정밀 측정)

  • 이영균;송인천;정성호;이병하;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.135-139
    • /
    • 2001
  • This paper describes a string resonator that is used for the interrogation system of a Fiber Bragg Grating(FBG) strain sensor. The strain on the fiber piece is calculated from the measured frequency based on that the natural frequency of a string is a function of the applied absolute strain. Existing research considered a fiber as a string, but a fiber is not a string in the strict sense due to its bending stiffness, thus the fiber should be modeled as a beam accompanied with an axial force. In the vibration modeling, the relationship between the strain and the natural frequency is derived, and then the resonance condition is described in terms of both the phase and the mode shape for sustaining resonant motion. Several experiments verify the effectiveness of the proposed model of the fiber. The performance of the string resonator is analyzed by measuring the frequency change according to the applied strains in the dynamic range of 1100$\mu\varepsilon$ referred to the displacement from capacitance sensor. From the experimental results, the implemented string resonator provides the accuracy of $\pm$3$\mu\varepsilon$, the quasi-static resolution of ~0.1$\mu\varepsilon$(rms) which amount to be $\pm$0.17$\mu\textrm{m}$ and ~6nm respectively, in case of fiber length of 56mm. For a dynamic strain, it can provide the accuracy of ~3$\mu\varepsilon$ until the frequency comes to 8Hz. As a consequence, the string resonator proposed for FBG sensor provides the high accuracy and the high resolution in strain measurement, and also it is expecting to be used, for the application, to not only strain but also displacement measuring device.

  • PDF

A Study on Influencing Factors in BWIM System and Its Field Applicability (BWIM시스템의 현장 적용성 및 영향인자에 관한 연구)

  • Yoo, Dong Gyun;Kyung, Kab Soo;Lee, Sung Jin;Lee, Hee Hyun;Jeon, Jun Chang
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.251-262
    • /
    • 2014
  • It has been considered that factors affecting accuracy of the estimated weight of moving vehicle by BWIM system are vehicle and bridge characteristics, and measurement conditions which is related to the strain curve. In this study, theoretical review and field test were performed to evaluate effect of these factors in BWIM system. From these evaluations, we proposed a way to improve accuracy of the estimated vehicle information in BWIM system. As the results, it was known that girder type and continuity of spans in bridge are not governing factor, but its plane shape gives large influence on accuracy of the estimated vehicle information. In addition, running speed of vehicle has also large effect on the estimated accuracy of axle distance if the distance between second and third axles is short. However, weight sum of the two axles can be estimated reasonably by assuming them as one axle.

Development of a 4-axis Auto-aligning System for Precision Measurement of 2-axis Feeding Systems Using Laser Interferometer (2축 이송계 정밀도 측정을 위한 레이저 간섭계 4축 자동정렬장치 개발)

  • Kim, Hyun-Soo;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.75-80
    • /
    • 2000
  • Although laser interferometer is widely accepted as a tool for measurement of motion accuracy the set-up procedure is time-consuming because of the strict requirement on alignment between laser head and optic units. This paper presents a 4-axis auto-aligning system which is useful for easy set-up of laser interferometer so as to evaluate precision of a 2-axis feeding system. This paper proposes two ideas for alignment in laser interferometer set-up: one is use of mirror and retroreflectors. and the other is taking advantage of the pre-defined movement and peculiar characteristic of retroreflecotrs. The pros and cons of the two methods are discussed. Illustrative experimental results are presented in which the developed system is applied to a XY table.

  • PDF

Development of Aspheric Surface Profilometry using 2nd Derivative (형상의 이차미분을 이용한 비구면 형상측정기술 개발)

  • Kim, Byoung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.104-109
    • /
    • 2011
  • I present a method of aspheric surface profile measurement using 2nd derivative of local area profile. This method is based on the principle of curvature sensor which measures the local 2nd derivative under test along a line. The profile is then reconstructed from the data on the each point. Unlike subaperture-stiching method and slope detection method, 2nd derivative method has strong points from a geometric point of view in measuring the aspheric surface profile. The second derivative terms of surface profile is an intrinsic property of the test piece, which is independent of its position and tip-tilt motion. The curvature is measured at every local area with high accuracy and high lateral resolution by using White-light scanning interferometry.

A Method of Boresight Error Compensation for Missile Radome (유도탄용 레이돔 시선각 오차 보정 기법)

  • Kim, Gwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.3 s.22
    • /
    • pp.56-63
    • /
    • 2005
  • The radome boresight error degrades the microwave seeker ability and the missile guidance performance. It increases the miss distance, also. This paper propose a method of radome boresight error measurement and compensation. The compensation method consist of radome analysis and radome compensation. In the radome analysis stage, we can know that the electromagnetic characteristics distorted by radome. In the compensation stage, the look-up table is built and used for compensation. The test uses a FMS(Flight motion simulator) and adjusts the FMS setup error for more accuracy. The result shows that not using an elaborate radome measurement equipment, the radome boresight error is well compensated easily.

Development of Diaphragm-type Stylus Probe for Ultra-precision On-machine Measurement Application (초정밀 기상측정용 다이아프램 타입 접촉식 프로브의 개발)

  • Lee, Jung-Hoon;Lee, Chan-Hee;Choi, Joon-Myeong;Kim, Ho-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.845-852
    • /
    • 2012
  • The diaphragm-type stylus probe was developed for ultra-precision on-machine measurement (OMM) application. This probe is equipped with two diaphragms which are parallel and one capacitive sensor is used for detecting the vertical motion of end tip in the stylus when it is contacted to the optical freeform surface. For better performance of proposed probes, several design parameters such as axial stiffness and the lateral deformations were investigated with finite element analysis techniques. To verify the feasibility, the profiles of the master sphere ball were measured on the ultra-precision milling machine. The measurement results show that the proposed probe can calculate the radius of the circle within the accuracy of 0.1 ${\mu}m$ for the ultraprecision optical surface.