• Title/Summary/Keyword: monochromator

Search Result 85, Processing Time 0.027 seconds

A study on the Fabrication of Wavelength Measurement System and the Spectrum Anslysis of Laser Diodes (파장측정 장치의 제작 및 반도체레이저의 광 스펙트럼분석에 관한 연구)

  • 오수환;이석정;박윤호;홍창희
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.359-364
    • /
    • 1995
  • A wavelength measurement system has been made using a monochromator and computer interfacing. The spectra of several light emitting diodes and the wavelength characteristics of Fabry-Perot LD and DFB LD have been measured with this system. The results show that this system can be practicalIy used in analyzing the lasing mode and the wavelength characteristics of the semiconductor lasers. asers.

  • PDF

The Crystal Structure of Tris(ethylenediamine)nickel(II)Chromate, $[Ni(C_2N_2H_8)_3]\cdotCrO_4$ ($[Ni(C_2N_2H_8)_3]\cdotCrO_4$의 결정구조)

  • Kim, Se-Hwan;Kim, Seung-Bin;Nam, Gung-Hae
    • Korean Journal of Crystallography
    • /
    • v.6 no.2
    • /
    • pp.75-79
    • /
    • 1995
  • The crystal structure of Tris(ethylenediamine)nickel(II)Chromate has been determined by X-ray crystallography. Crystal data : a=9.027(2)Å, c=9.751(5)Å이며, Z=2, V=687.9(2)Å3, Dc=1.714gcm-3, μ=21.635-1. The intensity were collected with Mo-Kα radiation (λ=0.7107Å) on an automatic four-circle diffractometer with a graphite monochromator. The structure was solved by Patterson method and refined by full matrix least-square methods using unit weights. The final R and S values were R=0.029, Rw=032, Rall=0.049 andS=0.018 for 342 observed reflections. The chromate ions are located at position of point of point symmetry 32 and their oxygens are sixfold disodered in an unusual way. Extensive strong hydrogen bonds between complex cations and chromatic anions are found in axial and equatorial directions.

  • PDF

Detection of N,N-Dimethylaniline in Ampicillin Trihydrate by Thin Layer Chromatography and Densitometry (박층크로마토그라피 및 농도 측정법에 의한 Ampicillin Trihydrate 중의 N,N-Dimethylaniline의 검색)

  • 이왕규;김박광;심창구
    • YAKHAK HOEJI
    • /
    • v.22 no.4
    • /
    • pp.238-241
    • /
    • 1978
  • A simple and convenient method of detecting N, N-dimethy laniline (D.M.A.) residues in ampicillin trihydrate (A.T.) was established. D.M.A. was extracted by chloroform from the chloroform presaturated N/10-ammonia water solution of A.T. and chromatographed on silica gel G thin layer. Blue spot appeared in 15minutes after spray of 2, 6-dichloroquinonechlorimide solution was compared with the blue spot of reference concomitantly processed. The developing solvent was prepared by mixing equal volume of cyclohexane and chloroform. To quantitate the amount of D.M.A. in A.T., T.L.C. was performed with the Eastmann Chromatogram sheet, then color density was measured by Cosmo Superclick densitometer. The developing solvent at this time was cyclohexane-chlorofonn (3+7) mixture. The peak areas obtained with the amount of D.M.A ranging from 0.05 to 2.0 .mu.g were linear to color density. Better sensitive results would be available with the densitometer equipped with monochromator.

  • PDF

Study on Mobile Broadband Coherent Anti-Stokes Raman Spectrometer For Combustion Diagnostics (연소진단용 이동형 광대역 코헤런트 반 스톡스 라만 분광기에 관한 연구)

  • Park, Chul-Woung;Park, Seung-Nam;Hahn, Jae-Won;Lee, Jong-Ung
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.2
    • /
    • pp.9-20
    • /
    • 1996
  • We construct a mobile broadband coherent anti-Stokes Raman spectroscopy system to measure the temperature of combustion gases. To improve the accuracy of CARS temperatures due to Stokes lasers, a modeless dye laser is constructed. A monochromator to disperse CARS spectra is also constructed in the spectrometer for easy portability. The accuracy of CARS temperature, measured in graphite tube furnace in reference to a radiation pyrometer, is better than 2 % from 1000 K to 2400 K. The CARS temperature error due to the variation of the spectral distribution of the modeless laser is measured to be less than 1.5 % during five hours operation. As a demonstration of combustion diagnosis, we applied the spectrometer to measure the temperature distribution of the propane air premixed flame.

  • PDF

Use of a Prism to Compensate the Image-shifting Error of the Acousto-optic Tunable Filter (음향광학변조필터의 이미지 이동 보상을 위한 프리즘 제안)

  • Ryu, Sung-Yoon;You, Jang-Woo;Kwak, Yoon-Keun;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.89-95
    • /
    • 2008
  • The Acousto-Optic Tunable Filter (AOTF) is a high-speed full-field monochromator which generates two spectrally filtered light beams with ordinary and extraordinary polarization state. Thus, AOTF is widely used to build full-field spectral imaging system or spectral domain interferometer. However, AOTF has a big problem that the angle of diffracted light changes according to the scanning of wavelength, which makes image shift on CCD plane In this paper, we propose an analytic design of prism system to compensate the image shift. The detailed analysis of light paths in a prism and basic experimental results are presented to verify our proposed compensation method. The experimental results agree with simulation results based on suggested prism model and image shift is minimized at optimal condition. Also, it can be extended to compensate the image shift for ordinary and extraordinary polarized light simultaneously.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

합성 스펙트럼 해석법과 소형 스펙트로메터를 이용한 Fulcher-α 시스템 해석 및 수소 분자 회전 운동 측정

  • Dang, Jeong-Jeung;Jeong, Gyeong-Jae;Hwang, Yong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.227.1-227.1
    • /
    • 2016
  • 플라즈마 방출광 진단법은 플라즈마에 특별한 영향을 주지 않으면서도 진단 정보를 안정적으로, 지속적으로 취득할 수 있는 우수한 진단 방법이다. 이러한 분광 진단의 신뢰성을 확보하기 위해서는 방출광의 정확한 측정과 해석이 중요하다. 방출광의 측정에 이용되는 분광 장비는 모노크로메터(monochromator)와 소형 스펙트로메터(spectrometer)가 주로 사용된다. 스펙트로메터의 경우 모노크로메터보다 분광 성능은 다소 부족하지만 가볍고 작은 크기로 인해 장비의 설치가 용이하고 가격이 저렴하다는 장점이 있다. 또한 모노크로메터에 비해 분광 성능이 낮은 대신 넓은 범위의 파장을 동시에 측정할 수 있는 장점이 있다. 따라서 스펙트로메터는 플라즈마의 모니터링에 주로 사용된다. 그런데 스펙트로메터의 기기적 선폭 증대(instrumental broadening)보다 조밀하게 위치한 스펙트럼들은 서로 중첩이 일어나 진단이 어려워진다. 특히 분자 띠 스펙트럼(molecular band spectrum)과 같은 경우 선 스펙트럼들이 매우 밀집된 형태를 이루고 있어 범용적인 스펙트로메터로 진단하기가 어렵다. 이러한 문제점을 해결하기 위하여 합성 스펙트럼 해석법(synthetic spectrum method)을 이용할 수 있다. 본 연구에서는 수소 플라즈마의 Fulcher-${\alpha}$ 띠 스펙트럼 해석에 합성 스펙트럼법을 적용하여 분자의 회전 온도가 측정 가능한지 확인하고, 고성능의 모노크로메터를 이용한 온도 측정 결과와 서로 비교하였다. 그리고 분자의 진동 상태(vibrational state)가 분자 회전 온도 측정에 미치는 영향과 이에 따른 측정의 한계 등을 제시하였다.

  • PDF

Construction Broadband CARS Spectrometer and Uncertainty Analysis of Temperature Measurement (광대역 CARS 분광기의 제작과 온도 측정의 정확도 분석)

  • 박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.226-232
    • /
    • 1993
  • A broadband CARS system is constructed for shot by shot measurement of a full CARS spectrum, which consists of a frequency doubled Nd:Yag laser, broadband mode-less laser and optical multi-channel analyzer installed in a double grating monochromator. To increase the accuracy of CARS temperature measurement and get better the fitting goodness, we have measured the slit function of the detection system and determined the analytical functional form of the slit function. Accuracy of the CARS system for temperature measurement is evaluated from the difference between the best-fit temperature of CARS spectrum and temperature of thermocouple reading. The uncertainty of the temperature measurement is found to be less than 1.5% in temperature range from 300 K to 1300 K.

  • PDF