• Title/Summary/Keyword: monitoring results

Search Result 8,898, Processing Time 0.044 seconds

Determination Methods of Pressure Monitoring Location in Water Distribution System (상수관망에서 수압모니터링지점 선정방법)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1103-1113
    • /
    • 2013
  • In this study, determination methods of the pressure monitoring location in water distribution system were introduced and applied to sample pipe network. The best determination method of the pressure monitoring location was suggested and applied to the real city pipe network. Three kinds of determination methods of pressure monitoring locations are categorized such as the sensitivity analysis according to changing roughness coefficient, pressure contribution analysis, and sensitivity analysis according to changing demand. Further-more, pressure contribution analysis and sensitivity analysis from the results of unsteady analysis were conducted and compared each other. From the results, the most accurate and simplest method was selected in this study. Therefore, the best method can be applied for the pressure management or leakage detection as a determination method of pressure monitoring location in water distribution system.

A Study on the Water Withdrawal Permit Rate and Monitoring Well Management of Bottled Water Manufacturers (먹는샘물 제조업체의 취수량 및 감시정 관리에 관한 고찰)

  • Son, Doo Gie;Park, Seunghyuk;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.329-337
    • /
    • 2019
  • Bottled water companies in Korea are required to conduct an environmental impact assessment of their drinking water supply at least six months before the expiration of their five-year marketing and production license. The water level drawdown, production well water quality, and monitoring well observation results are the most important items that are evaluated in the assessment report. Here we evaluate the relationship between well drawdown and pumping capacity with pumping time from the production wells of bottled water manufacturers located in Cretaceous granite (site A) and Precambrian gneiss (site B). The method to reduce the pumping capacity is more effective in decreasing the drawdown than the method to simultaneously control the pumping and recovery times. Furthermore, the monitoring data from the pH monitoring sensors that were installed in Precambrian gneiss (site C) yield pH values that increase with time and eventually plateau at a certain value. We therefore propose that pH monitoring is either discontinued or improved to provide more reliable and usable results.

Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility study

  • Sangalli, Linda;Savoldi, Fabio;Dalessandri, Domenico;Visconti, Luca;Massetti, Francesca;Bonetti, Stefano
    • The korean journal of orthodontics
    • /
    • v.52 no.2
    • /
    • pp.123-130
    • /
    • 2022
  • Objective: To evaluate if a remote digital monitoring system added at the end of orthodontic treatment could positively influence the retention phase by reducing the occurrence of misfit of removable appliances, number of emergency appointments (EA), and orthodontic relapse. Methods: Twenty-seven patients who completed active orthodontic treatment were divided into the study and control groups. In addition to the standard chairside follow-up appointments at month 1 (T1), month 3 (T2), month 6 (T3), the study group patients were monitored using Dental Monitoring® with monthly intra-oral scans. Occurrence of misfit of removable retainers, number of EAs, and intercanine width change were recorded for both groups. Differences in EAs and retainer fit were assessed using the chi-square test. Intra-group and inter-group differences in the intercanine width were assessed with Friedman test and Mann-Whitney U test, respectively (α = 0.05). Results: The study group showed a significantly lower occurrence of misfit of removable retainers (p = 0.027) compared to the control group. No significant inter- and intra-group difference was found in the EAs and intercanine width change at each time-point. Conclusions: Integrating remote monitoring systems, such as Dental Monitoring®, to the retention phase of the orthodontic treatment may lower the occurrence of misfit of removable retainers. However, a small sample size and a short observation period limit the strength of this evidence. These preliminary results tentatively suggest that remote monitoring technologies may be beneficial, especially during the COVID-19 pandemic, when the regularity of in-office visits might be disrupted.

A Plot Scale Experiment to Analysis the NPS Reduction by Silt Fence and Vegetated Ridge for Non-Irrigated Cropland (실트펜스와 식생밭두렁 적용을 통한 밭 비점오염 저감효과 분석을 위한 포장실험 연구)

  • Kim, Sung-Jae;Park, Tae-Yang;Kim, Sung-Min;Jang, Jeong-Ryeol;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.19-27
    • /
    • 2012
  • The objective of this study was to test the pollutant reduction effect by the silt fence and vegetated ridge through field monitoring. The experiment plots were established with two replication and three treatments. Each plot was designed with 5 m width, 22 m length, and 3 % slope. Flumes with the floating type stage gages were installed at the outlet of each plot to monitor the runoff. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Cultivated crops were spring daikon and autumn chinese cabbage. Analysis of variance (ANOVA) indicated that the water quality concentration from three experiment plots were not significantly different in 5 % of significant level. The monitoring results showed that the average pollution loads reduced by silt fence compared to control were SS 75.33 %, TN 40.87 %, TP 56.58 %, BOD 52.12 %, COD 36.07 %, TOC 34.99 %; by vegetated ridge compard to control were SS 65.27 %, TN 81.80 %, TP 54.26 %, BOD 67.09 %, COD 46.55 %, TOC 43.30 %. Analysis of Spearman's rank correlation coefficient showed that BOD-SS and SS-Turbidity were highly related at the silt fence and vegetated ridge plots. In all plots, SS-Turbidity and TP-TN relations were relatively high. The monitoring results showed that the silt fence and vegetated ridge were effect method to reduce the pollutant loads from the field runoff. Long-term monitoring is required to obtain more quantitative reduction effect for diverse crops and to increase the reliability of results.

Performance evaluation of soil-embedded plastic optical fiber sensors for geotechnical monitoring

  • Zhang, Cheng-Cheng;Zhu, Hong-Hu;Shi, Bin;She, Jun-Kuan;Zhang, Dan
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.297-311
    • /
    • 2016
  • Based on the distributed fiber optic sensing (DFOS) technique, plastic optical fibers (POFs) are attractive candidates to measure deformations of geotechnical structures because they can withstand large strains before rupture. Understanding the mechanical interaction between an embedded POF and the surrounding soil or rock is a necessary step towards establishing an effective POF-based sensing system for geotechnical monitoring. This paper describes a first attempt to evaluate the feasibility of POF-based soil deformation monitoring considering the POF-soil interfacial properties. A series of pullout tests were performed under various confining pressures (CPs) on a jacketed polymethyl methacrylate (PMMA) POF embedded in soil specimens. The test results were interpreted using a fiber-soil interaction model, and were compared with previous test data of silica optical fibers (SOFs). The results showed that the range of CP in this study did not induce plastic deformation of the POF; therefore, the POF-soil and the SOF-soil interfaces had similar behavior. CP was found to play an important role in controlling the fiber-soil interfacial bond and the fiber measurement range. Moreover, an expression was formulated to determine whether a POF would undergo plastic deformation when measuring soil deformation. The plasticity of POF may influence the reliability of measurements, especially for monitored geo-structures whose deformation would alternately increase and decrease. Taken together, these results indicate that in terms of the interfacial parameters studied here the POF is feasible for monitoring soil deformation as long as the plastic deformation issue is carefully addressed.

Hygiene Monitoring of Food for Children's Foodservice Using the IoT-based Smart Food Safety Management System (iMEAL) (사물인터넷(IoT) 기반 스마트 급식안전관리시스템(iMEAL) 개발 및 이를 적용한 어린이 급식소용 음식의 위생모니터링)

  • Eun-Jin Lee;Sang-Hyeok Seo;Hye-Kyung Moon
    • Journal of the Korean Dietetic Association
    • /
    • v.30 no.1
    • /
    • pp.61-73
    • /
    • 2024
  • This report was prepared to introduce the developed Internet of Things (IoT)-based Smart Food Safety Management System (iMEAL) for children's foodservices registered in the Center for Children's Foodservice Management and report the results of hygiene monitoring through microbial analysis of two foods simulated and distributed based on this system. The program consisted of three menu screens: a foodservice management and meal inspection function, a refrigerator/freezer monitoring function, and a sanitary/safety inspection log function. Data such as cooking temperature, refrigerator and freezer temperature, salinity, and chlorine concentration were collected using IoT sensors or terminals, and hygiene safety inspection diary results (recorded by cooks) were transmitted to the Internet and stored. The APCs (3.78±0.07 log CFU/g) and E. coli (not detected) in stir-fried pork teriyaki sauce and the heating process met cooking standards. Similarly, the APCs (4.05±0.05 log CFU/g) and E. coli (not detected) in cucumber/chomuchim, which was not heated, also met cooking standards. APCs increased over time when cooked food was left for 1 hour, 1.5 hours, or 2 hours but remained acceptedable. Based on hygiene monitoring results of these two foods, using the i-MEAL system resulted in the safe production and distribution of children's food.

The Study of the Validity Test on the Self-monitoring Scale (자기 검색척도(Self-Monitoring Scale)의 타당성 검정에 관한 연구)

  • 이선아
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.751-759
    • /
    • 1998
  • The study of the validity test on the self-monitoring scale for nurses In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of the self-monitoring scale. The self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen(1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity were found in the previous research findings. It is also important to note that Snyder's self-monitoring scale did not factor-load at over. 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lacks convergent validity as the sub-factors of the scale failed to prove its uni-dimensionality. The A self-monit oring scale not only fail to overcome the problems of Snyder's self-monitori ng scale but even lost the attractiveness of the self-monitoring scale. In this study it was also found that the A self-monitoring scale was not classified in either in a two or three-factor classification as hypothesized. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used and has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were class ified and loaded as expected. Reliability was also proven by checking Cronbach's α for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound : however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original nor the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over. 30, too high for the two factors in the test results of Factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF

A Study on Analysis of Construction Monitoring Cost and Improvement Measures of Railway Tunnel Construction in Seoul (서울시 철도터널 건설공사의 공사계측비 분석 및 개선방안 연구)

  • Jong-Tae Woo
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.18-30
    • /
    • 2023
  • Purpose: This study is to contribute to the development of monitoring technology through the increase of confidence in construction monitoring by deriving the analysis of construction monitoring cost and improvement measures of railway tunnel construction in Seoul. Method: It presents the status on design and contract of construction monitoring cost, status on application construction monitoring cost and its analysis, analysis on safety management cost and quality management cost, expansion of application of the price calculation standard for monitoring management services to improve this, and monitoring for direct order of ordering organization. Results: If the monitoring management service that was meanwhile ordered as included in the construction work is performed by the directly selected company of ordering organization through the preliminary screening for bidding qualification, then the improvement of monitoring quality and the accurate monitoring data can be secured. Conclusion: For the price calculation standard for monitoring management service, the application of actual cost addition method under the Engineering Promotion Act and the calculation standard of monitoring management cost for standard estimation for ground survey should be extended through the direct order of ordering organization, not the method to be included in the net construction cost where it is performed by a subcontractor via contractor.

Classifying meteorological drought severity using a hidden Markov Bayesian classifier

  • Sattar, Muhammad Nouman;Park, Dong-Hyeok;Kwon, Hyun-Han;Kim, Tae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.150-150
    • /
    • 2019
  • The development of prolong and severe drought can directly impact on the environment, agriculture, economics and society of country. A lot of efforts have been made across worldwide in the planning, monitoring and mitigation of drought. Currently, different drought indices such as the Palmer Drought Severity Index (PDSI), Standardized Precipitation Index (SPI), Standardized Precipitation Evapotranspiration Index (SPEI) are developed and most commonly used to monitor drought characteristics quantitatively. However, it will be very meaningful and essential to develop a more effective technique for assessment and monitoring of onset and end of drought. Therefore, in this study, the hidden Markov Bayesian classifier (MBC) was employed for the assessment of onset and end of meteorological drought classes. The results showed that the probabilities of different classes based on the MBC were quite suitable and can be employed to estimate onset and end of each class for meteorological droughts. The classification results of MBC were compared with SPI and with past studies which proved that the MBC was able to account accuracy in determining the accurate drought classes. For more performance evaluation of classification results confusion matrix was used to find accuracy and precision in predicting the classes and their results are also appropriate. The overall results indicate that the MBC was effective in predicating the onset and end of drought events and can utilized for monitoring and management of short-term drought risk.

  • PDF

Wind induced response of an elevated steel water tank

  • Sepe, Vincenzo;Zingali, Antonino E.
    • Wind and Structures
    • /
    • v.4 no.5
    • /
    • pp.383-398
    • /
    • 2001
  • The paper describes the results of the monitoring of an elevated steel water-tank with unusual shape, 85 m high and 40 m wide. The research was carried out analysing both the static and dynamic behaviour under wind actions. The instruments used (some of which were employed for the first time for this project) are described and the data processing procedures are discussed. Comparison between the experimental results and those obtained through a numerical model gives interesting information both on the structural behaviour and on the characterisation of wind actions.