• Title/Summary/Keyword: monitoring results

Search Result 8,954, Processing Time 0.035 seconds

Cutting Vibration Monitoring using a Spindle Displacement Sensor in Turning (주축 변위 센서를 이용한 선삭 중의 절삭 진동 측정)

  • Kim IlHae;Kim JinHyun;Park Man-Jin;Kim Jong-Hyuk;Yang Hee-Nam;Jang. DongYoung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.55-61
    • /
    • 2004
  • Chatter monitoring is also important for realizing an unmanned machining system. while many researches were done on this area, it is still a difficult job to detect very small amplitude amount of chattering. A monitoring system using a capacitive spindle displacement sensor was developed to monitor cutting vibration in turning in this research. The variance of the measured spindle displacement signals using the developed sensor was calculated and utilized to quantify the small vibration in machining. The results were compared with variance obtained using a tool dynamometer. The result showed that the developed system could be utilized in monitoring the subtle changes of cutting vibrations with high sensitivity confidence.

CUTTING VIBRATION MONITORING USING A SPINDLE DISPLACEMENT SENSOR IN TURNING (주축 변위 센서를 이용한 선삭 중의 절삭 진동 측정)

  • 김일해;김진현;장동영
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.516-522
    • /
    • 2003
  • Monitoring chattering is also important for realizing an unmanned machining system While many researches were done on this area, it is still a difficult job to detect very small amplitude amount of chattering. A monitoring system using a capacitive spindle displacement sensor was developed to monitor cutting vibration in turning in this research. The variance of the measured spindle displacement signals using the developed sensor was calculated and utilized to quantity the small vibration in machining. The results were compared with variance obtained using a tool dynamometer. The result showed that the developed system could be utilized in monitoring the subtle changes of cutting vibrations with high sensitivity confidence.

  • PDF

Hybrid Monitoring for Damage Detection in Structural Joints (구조 접합부의 손상검색을 위한 하이브리드 모니터링)

  • Kim Jeong-Tae;Na Won-Bae;Lee Byung-Jun;Hong Dong-Soo;Do Han-Sung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.225-231
    • /
    • 2006
  • The purpose of this study is to develop a promising hybrid structural health monitoring system for structural joints. For this propose, the combined use of vibration-based techniques and electro-mechanical impedance technique is employed. For the verification of the proposed health monitoring scheme, a series of damage scenarios are designed to simulate various situations at which the connection joints can experience during their service life. The obtained experimental results, modal parameters and electro-magnetic impedance signatures, are carefully analyzed to recognize the connecting states and the target damage locations. From the analysis. it is shown that the proposed hybrid health monitoring system is successful for acquiring global and local damage information on the structural joints.

  • PDF

Application of the Determination Method of Monitoring Location in Real Water Distribution System (실제 상수관망에 대한 모니터링 지점선정방법의 적용)

  • Park, Yong-Gyun;Jung, Sung-Gyun;Kwon, Hyuk-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.617-623
    • /
    • 2015
  • In this study, determination methods of monitoring location in water distribution system were suggested and applied to real test bed. Small block of Gwangtan water distribution system is consisted of 582 pipes, 564 junctions, 1 reservoir, and 1 pump station. Small block of Ho Chi Minh water distribution system is consisted of 162 pipes, 148 junctions, and 1 reservoir. Two small block water distribution systems were analyzed by pressure contribution analysis method to determine the optimum monitoring locations. The pressure change was estimated at each junctions by the additional demand at a junction. From the results, the optimum monitoring location can be determined by rank of pressure contribution index at each junctions due to demand change at a junction.

A Study on the Implementation and Practical Application of Web Monitoring System (웹 모니터링 시스템 구현 및 활용 방안 연구: 쇼핑몰 이용고객에 대한 응답소요시간 평가를 중심으로)

  • Park, Chul-Jae;Cho, Jae-Gyeun
    • The Journal of Information Systems
    • /
    • v.16 no.2
    • /
    • pp.35-49
    • /
    • 2007
  • The web monitoring is a procedure to detect and monitor the change of a particular information from the web site. In this paper, we propose a monitoring system to survey the response time for the customers chi an internet shopping mall. This system we designed, decreases the network overload and guarantees the accuracy as well as the reliability of the information by using an interactive agent. This interactive agent we constructed, is written in Java and controlled by the high-level information such as the index or the robot. from the N web site, we extracted the web monitoring results of keyword "LCD Monitor" and verified our system's efficiency. The performance of the system is tested and the result is illustrated.

  • PDF

Analysis of Nonpoint Source Pollution Runoff from Urban Land Uses in South Korea

  • Rhee, Han-Pil;Yoon, Chun-Gyeong;Lee, Seung-Jae;Choi, Jae-Ho;Son, Yeong-Kwon
    • Environmental Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.47-56
    • /
    • 2012
  • A long-term nationwide nonpoint-source pollution monitoring program was initiated by the Ministry of Environment Republic of Korea (ME) in 2007. Monitoring devices including rain gauges, flow meters, and automatic samplers were installed in monitoring sites to collect dynamic runoff data in 2008-2009. More than 10 rainfall events with three or more antecedent dry days were monitored per year. More than 10 samples were collected and analyzed per event. So far, five land use types (single family, apartments, education facilities, power plants, and other public facilities) have been monitored 23 to 24 times each. Characterization of the runoff from different land use types will aid unit load estimation in Korea and hopefully in other countries with similar land use. The monitoring results will be reported regularly at national and international levels.

Process Monitoring in Laser Welding with Photodiodes (광센서를 이용한 레이저용접공정 모니터링)

  • 방세윤;윤충섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.474-478
    • /
    • 1996
  • Process monitoring in laser welding is essential for automation and quality control of products. Various signals from laser welding, such as plasma, sound, optical signals, etc., are utilized for monitoring the process and detecting abnormal weld conditions. In this study, both W light from plasma formed above the weld pool and IR signal from the melting pool are detected with photodiodes and PC-based A/D board, and analyzed to give a guidance about the weld quality. Experimental results show the possibility of using the signals for predicting and evaluating the weld qualify and adapting into the system for on-line process monitoring.

  • PDF

Low Attenuation Waveguide for Structural Health Monitoring with Leaky Surface Waves

  • Bezdek, M.;Joseph, K.;Tittmann, B.R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.241-262
    • /
    • 2012
  • Some applications require structural health monitoring in inaccessible components. This paper presents a technique useful for Structural Health Monitoring of double wall structures, such as double wall steam pipes and double wall pressure vessels separated from an ultrasonic transducer by three layers. Detection has been demonstrated at distances in excess of one meter for a fixed transducer. The case presented here is for one of the layers, the middle layer, being a fluid. For certain transducer configurations the wave propagating in the fluid is a wave with low velocity and attenuation. The paper presents a model based on wave theory and finite element simulation; the experimental set-up and observations, and comparison between theory and experiment. The results provide a description of the technique, understanding of the phenomenon and its possible applications in Structural Health Monitoring.

An Evaporative System Monitoring Method Using a Virtual HC Sensor (가상 HC 센서를 이용한 Evaporative System Monitoring 방법에 대한 연구)

  • 서진호;박재홍;윤형진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.40-47
    • /
    • 2003
  • This paper presents a new evaporative system monitoring method using a virtual HC sensor for an automotive on-board diagnosis. A development was made at providing mathematical expressions from the lambda control information to estimate the HC mass flow purged into the intake manifold from the canister for implementing a virtual HC sensor. The change of the lambda averagevalue reflected the influence of the additional fuel from purging results the sensor estimation of the purged HC amount. Based on this virtual HC sensor, a new evaporative system monitoring method was proposed comparing the amount of purged HC amount with the amount of the HC gas evaporated from the fuel tank and absorbed into the canister. Finally, the method was validated with a simulation using the data logged from the retail car.

Development of Microcomputer-Based On-Line Monitoring System of Spot Weld Quality (마이크로 컴퓨터를 이용한 온라인 점용접 품질 감시체제 개발에 관한 연구)

  • 김교형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.241-246
    • /
    • 1986
  • A new method of on-line monitoring of spot weld quality is proposed by analysing weld votage signal. Weld voltage signal has been modeled by autoregressive model which is suitable for on-line modeling scheme, and order of the model is determined by F-test. From the chosen model, strength. Upon experimental results, it has been shown that fundamental frequency dispersion of weld voltage can be used as a good parameter like maximum thermal expansion in on-line monitoring of spot weld quality. Microcomputer implementation of the proposed monitoring method is also developed and presented.