• Title/Summary/Keyword: monitoring results

Search Result 8,859, Processing Time 0.041 seconds

On-line PD Monitoring Using UHF Technique (UHF 가술을 이용한 온라인 PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.115-118
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers. is designed, which has been installed inside the oil tank of a transformer by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Application of Physiologically Based Pharmacokinetic Modeling with Biological Monitoring Data for Risk Assessment (생물학적 모니터링 데이터를 기초한 PBPK 모델의 활용)

  • Yang, Mi-Hi;Yang, Ji-Yeon;Yi, Bit-Na;Lee, Ho-Sun
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.1 s.56
    • /
    • pp.1-8
    • /
    • 2007
  • Biological monitoring, analyses of internal dose for exposure to toxicants, has been thought as one of the belt approaches for risk assessment. As the amount detected in human samples is generally very low, typically in the parts-per-bilion (ppb) or parts-per-trillion (ppt) range, analytic technologies such at HPLC, GC/MS, LC/MS, and LC/MS/MS have been continuously developed. In addition, route specific and sensitive exposure biomarkers have been developed for proper biological monitoring. PBPK modeling, particularly reverse dosimetry, has been emphasized as an useful method via interpretation of biological monitoring results for regulation of toxicants. Thus, this review is focused on the use of PBPK dosimetry models for toxicology research and risk assessment in Korea.

Development of Intelligent Landscape Lighting Power Control and Monitoring System with Solar Cell Generator Equipment (태양광발전설비와 연계한 지능형 경관조명 전력제어 및 모니터링 시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won;Kim, Hyung-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.99-104
    • /
    • 2011
  • In this paper, the intelligent landscape lighting power control and monitoring system with solar sell generator equipment is proposed. The first, the intelligent landscape lighting power controller is designed using the fuzzy logic control method. And the fuzzy logic controller is used to save power consumption for various reference intensity of the illumination. The second, the GUI monitoring system is presented. It has control and display faculty. And the practical experiment device is used to evaluate the performance criteria of the proposed intelligent landscape lighting power control system with the solar cell power generation equipment. From the experiment results, we present the property of proposed fuzzy controller such as steady state error, the tracking and power consumption characteristic for the reference intensity of illumination. And also we show the superiority of power control as well as the characteristic of GUI monitoring system in the proposed system.

Development of Electrical Safety Monitoring System for Conventional Markets (재래시장 전기안전 감시시스템 개발)

  • Lee, Sang-Ick;Kim, Gi-Hyun;Bae, Seok-Myung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.552-556
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of conventional markets is introduced the electric safety monitoring system which is suitable in conventional markets. Investigate the actual conditions about electrical equipment of conventional markets, electrical safety monitoring system was constructed. Electrical safety monitoring system to verify the performance of the experiment was to build a test bed. Research results will be used with the data for the reliability security of the electric safe system operation which follows in the conventional markets actual proof equipment construction which will be advanced.

Development of Real-time Monitoring System for Muscle Tension by High Intensity Laser Therapy (고출력 레이저 치료를 통한 근강직 완화의 실시간 모니터링 연구)

  • Hong, Jungsun;Youn, Jong-In
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.128-134
    • /
    • 2012
  • Currently, high-intensity laser therapy (HILT) is increasingly used in various muscle disorders like muscle tension. Our proposed study includes the development of the real-time monitoring system using a myotonometer for HILT. The developed system consists of a piezoelectric sensor and laser distance sensor for muscle stiffness monitoring during the treatments. The results demonstrated that the level of muscle tension was rapidly decreased after 3 minutes of the high-intensity laser treatment when compared to the control group. The combined HILT and realtime muscle tension monitoring system may help to evaluate the therapeutic procedure and efficient treatments for various muscle pains.

The Development of Real-Time Wireless Remote Corrosion Monitoring System Using TRS(II) (TRS를 이용한 실시간 무선 원격 부식감시시스템 개발(II))

  • Bae, Jeong-Hyo;Kim, Dae-Kyeong;Ha, Tae-Hyun;Lee, Hyun-Goo;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.618-620
    • /
    • 1999
  • The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or collapse of bridge and building and so on. So, he has been spent the money and the time for corrosion monitoring and analysis of measuring data. Therefore, KERI(Korea Electrotechnology Research Institute) has developed the real-time wireless remote corrosion monitoring system using by TRS(Trunked Radio System). The results of development for corrosion monitoring system are described briefly. Especially, the interfacing technology between the server and rectifier introduced in this paper.

  • PDF

Monitoring of Early-age Behavior of Concrete Retaining Wall by FBG Sensors (FBG센서를 이용한 콘크리트옹벽 초기재령 특성 모니터링 연구)

  • Jang, Il-Young;Yun, Ying-Wei;Kim, Young-Gune
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.89-90
    • /
    • 2009
  • FBG temperature sensor and strain sensor has been used to monitoring shrinkage and temperature of concrete retaining wall in construction site in its casting early age. The test results indicate that this monitoring method is a practical method for monitoring concrete at very early age. The monitoring technique used in this research could be extended to monitor shrinkage and temperature for mass concrete structure.

  • PDF

The study on Response of the Sensor for monitoring of Chloride Penetration in Concrete (콘크리트내 비래 염소이온 침투 모니터링을 위한 부식센서의 응답성능 평가에 관한 연구)

  • Shin, Sang-Heon;Lee, Hyun-Seok;Ryu, Hwa-Sung;Kim, Bo-Seok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.172-173
    • /
    • 2014
  • The study is used to verify the applicability of the sensor to monitor penetration of chloride into the concrete, like real coastal environment. After manufacturing the specimen adapt corrosion sensor for chloride penetration monitoring, chloride spray experiment was conducted. And then, It was checked the possibility of monitoring of the penetrated chloride by measuring the resistance of the corrosion sensor that was embedded in each depth of the concrete. Experimental results, it is confirmed that the corrosion resistance of the sensor was increased depending on the concentration of chloride. Therefore, it is estimated that the sensor is available for monitoring of chloride penetration.

  • PDF

Nonlinearity Detection and Compensation in Radio over Fiber Systems Using a Monitoring Channel

  • Kim, Sung-Man
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.3
    • /
    • pp.167-171
    • /
    • 2015
  • A radio over fiber (RoF) system is a kind of analog optical transmission system and considered as a strong candidate for the next-generation fronthaul link in the future mobile network. In RoF systems, nonlinearity compensation is essential to increase the link capacity. In this paper, we propose a nonlinearity detection and compensation scheme using a monitoring channel in RoF systems. A monitoring channel is added at the transmitter site and used for transmitting a reference signal in an RoF transmission. The nonlinearity in the RoF transmission is detected by comparing the received monitoring signal and the original reference signal at the receiver site. Finally, the nonlinearity is compensated at the receiver by giving the reverse function of the detected nonlinearity. Our results show that the proposed scheme can almost remove the error vector magnitude degradation induced by the nonlinearity in the RoF system.

The Analysis of the Temperature Effects on Long-span Strut by Field Monitoring and Numerical Analysis (현장계측 및 수치해석에 의한 장대버팀보의 온도영향 분석)

  • Lee, Moon-Joo;Choi, Sung-Kun;Shin, Se-Young;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1468-1475
    • /
    • 2005
  • In this study, the effects of temperature on loading of long-span strut were studied by using field monitoring and numerical analysis. For the field monitoring, several sensors, such as stain gages, temperature gages and load cells, were installed on the struts. From the monitoring results, the relation between temperature and axial force of the struts was analysed. By numerical analysis, the changes of axial force of strut and lateral displacement of wall due to temperature change were described with the strut length and ground conditions.

  • PDF