• 제목/요약/키워드: monitoring of $CO_2$ underground

검색결과 41건 처리시간 0.022초

공동주택 지하저수조의 수질변화 및 부식성 특성 (Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment)

  • 장준영;김주원;황유훈;김기팔;신현상;임병란
    • 한국물환경학회지
    • /
    • 제38권6호
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.

지중온도 경사를 이용한 효율적 지중에너지 이용 방안에 관한 연구 (A Study on Effective Energy Use of the Open Type Ground Heat Exchanger Using Underground Temperature Gradient)

  • 류형규;정민호;이병석;류효준;최현준;최항석
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.401-408
    • /
    • 2014
  • This paper proposes an optimum operation method for open type ground heat exchangers. A series of TRTs and artificial heating/cooling operations were carried out while monitoring temperature in the hole of SCW. The ground temperature naturally increases with depth, but a switch between the cooling/heating mode results in a change in the distribution of ground temperature. The effect of the mode change was evaluated by performing LMTD and COMSOL multiphysics analysis for a reduced model with the depth of 150 m. As a result, in the cooling mode, the upstream operation is more efficient than the downstream operation and reduces EWT by $2.26^{\circ}C$. On the other hand, in the heating mode, the downstream operation is advantageous over the upstream operation and increases EWT by $3.19^{\circ}C$. The merit of the optimum operation will be enhanced for the typical dimension of SCW with a depth of 400~500 m. In the future, an open type ground heat exchanger system adopting the optimum operation with variation in the ground temperature will be used in practice.

굴포천 임시방수로 굴착구간 주변의 지하수 수위 변동 유형 분류 (Classification of Groundwater Level Variation Types Near the Excavated Area of the Temporary Gulpocheon Discharge Channel)

  • 김창훈;이수곤;한정상;김남주;전병추
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.631-641
    • /
    • 2014
  • 지하 대수층에 가해진 수문학적 충격에서 나타난 지하수위 변화를 관측하고 분석하여 굴포천 임시방수로구간의 지하수 수위 변동 특성을 규명하였다. 지하수위란 그 지점을 지나가는 등포텐셜 값으로 지하수 압력이 그 위치에서 대기압과 균형을 이루고 있는 것으로, 이는 고정된 것이 아니라 수문학적 충격에 대응해서 변화하게 되는데 관측지점으로부터 지하수면까지의 깊이를 반복적으로 측정함으로서 파악할 수 있다. 김포-김포 국가지하수관측소의 1일 지하수 유출수문곡선의 지하수위 변화식과 변동폭을 평가요소로 하여 18개소의 관측시스템의 지하수 변동 특성을 영향형, 관측요망형, 비영향형 등으로 분류하였다. 그 결과 영향형은 전체의 50%로 수문학적 충격에 의해 수위변화가 민감하게 반영되며 임시방수로로부터 거리가우선적인 요인으로 판단된다. 관측요망형은 27.8%로 2개의 평가요소 중 1개가 기준에 미달한 경우이다. 비영향형은 22.2%로 지하수위 변화가 강우사상에 대해서만 반응함으로써 두 가지의 평가요소를 초과한 것들이다.

지하원유비축기지 공동주변 지하수의 수질화학적 변화와 기밀성과의 관계 (Relationship between Hydrochemical Variation of Groundwater and Gas Tigtness in the Underground Oil Storage Caverns)

  • 정찬호
    • 지질공학
    • /
    • 제14권3호
    • /
    • pp.259-272
    • /
    • 2004
  • 이 연구는 임해지역 지하원유비축기지 주변에서의 지하수 수리화학적 변화를 관측하여 원유저장 후 운영에 따른 저장공동의 기밀성 확보에 수질화학적 영향을 평가하고자 한다. 연구지역의 모암은 편마암이지만 바다와 호수를 끼고 있어 지하수의 화학조성은 모암의 영향보다 해수의 혼합, 수벽공 주입수, 그라우팅 재료의 용해와 같은 외적인 요소에 의해 상당한 영향을 받은 것으로 보인다. 4차례에 걸친 지하수의 수질분석 결과 측정시 기와 관측정에 따라서 큰 수질변화를 보인다. 전반적 인 지하수의 특성은 알카리성의 높은 전기전도도 값을 보이고, 일부 관측정 지하수는 고알카리성과 고염분의 특성을 보인다. 지하수의 화학적 유형은 Na-Cl형 > Ca-Cl 형 > $Ca-HCO_3(CO_3)$형의 순으로 우세한 경향을 보인다. 열역학적 평형관계를 계산해 본 결과 대부분의 지하수가 탄산염광물에 대해서는 침전성 환경을 앨바이트에 대해서는 용해성 환경을 보인다. 그러나 단열의 충전효과가 큰 점토광물의 침전은 거의 확인되지 않아 암반 단열의 밀봉효과와 그로 인한 기밀성 확보에는 큰 효과가 없을 것으로 보인다. 총유기탄소량 (TOC)은 원유저장 후 약간의 증가하는 경향을 보인다. 관측정 지하수의 $EpCO_2$ 함량은 0$\~$41.3의 범위를 보여 원유에 혼합으로 발생될 수 있는 높은 이산화탄소의 압력은 현재로서는 거의 무시할 수 있다.

실규모 굴착 시험장에서의 시간경과 물리탐사 자료 분석 (Time-lapse Geophysical Survey Analysis for Field-scale Test bed of Excavation Construction)

  • 신동근;송서영;김빛나래;유희은;기정석;남명진
    • 지질공학
    • /
    • 제29권2호
    • /
    • pp.137-151
    • /
    • 2019
  • 굴착공사 중 발생할 수 있는 지반함몰 사고를 방지하기 위해 굴착공사 주변 지층변화를 분석하고 모니터링하는 탐사기법과 기술이 필요함에 따라 다양한 탐사기술들을 적용, 보완함으로써 해석 기법을 향상시키는 것이 요구된다. 이 연구에서는 굴착공사 중 발생할 수 있는 지반침하 위험요소와 굴착, 지하수 등에 의한 이완영역을 탐지하기 위한 실규모 현장 실험을 실시하였다. 현장 실험을 수행하기 위해 실규모 굴착현장 테스트베드를 구축하고, 도심지 현장을 고려한 탐사법 중 전기비저항 탐사, 다중채널분석표면파탐사를 활용, 각 개별탐사의 적용 유효성 검토 및 모델링을 이용한 최적 탐사변수 도출과 설계, 탐사결과의 상호연관성을 비교 해석하였다. 이 연구 결과, 각 탐사별로 이완영역에 대한 영향을 확인할 수 있었으며, 특히 전기비저항탐사를 이용해 지하수면 위치를 확인하고 굴착에 대한 영향 파악할 수 있었다. 추후 지하수의 영향을 고려한, 즉 굴착면을 고려한 모델링에 대해 추가 연구가 필요할 것으로 보인다.

서울 시내 궁궐 수원의 수질과 유동 특성 (Characteristics of Quality and Flow of Water Resources at Palaces in Seoul Metropolitan)

  • ;이재민;우남칠;김연태;이강진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권2호
    • /
    • pp.61-76
    • /
    • 2011
  • This study was objected to provide suggestions for best management practices to restore the cultural and historical values of the wells in Palaces as well as their water qualities. Water resources in the five Palaces in Seoul Metropolitan, including Gyeongbokgung, Changdeokgung, Changgyeonggung, Jongmyo Shrine, and Deoksugung, were surveyed for their physical flows and chemical compositions from April to July in 2010. Ground waters in most wells were found at depths within 5 m from the ground surface, showing typical water-table aquifer systems. Hydraulic gradients indicate water resources in Gyeongbokgung, Changdeokgung, and Changgyeonggung flowing toward south, and toward east in Deoksugung area. Especially, water-level fluctuation data at S-10 in Deoksugung implied the influence of groundwater discharge facility. In Jongmyo Shrine, water was not detected in wells, indicating the water level was lower than the well depth. Based on the water chemistry and stable isotope analyses, water resources and their qualities appeared to be formed by the water-rock interaction along the groundwater paths. S-10 (Deoksugung) and S-14 (Changgyeonggung) samples were contaminated with nitrate ($NO_3$) in levels of higher than Korean drinking water standard, 10 mg/L as $NO_3$-N, but once in four sampling campaigns. In the situation that water resources in Palaces still maintain natural characteristics, the materials that will be used for the restoration and improvement of the Palace water supplies should be carefully selected not to disturb the natural integrity. In addition, because the wells are located in the center of metropolitan area, a systematic monitoring should be applied to detect and to manage the potential impacts of underground construction and various pollution sources.

투수시험과 지하수 모니터링을 통한 매립층의 배수불량 원인 분석 (Analysis about Fill Deposit Poor Drainage through Permeability Test and Groundwater Monitoring)

  • 정희석;이강일;김준석
    • 한국재난정보학회 논문집
    • /
    • 제14권2호
    • /
    • pp.165-173
    • /
    • 2018
  • 연구목적 : 유적지와 같은 지역은 과거 산으로 둘러 쌓인 구릉지 등에 분포할 경우 강우시 매립층에 분포하는 흙은 투수능력이 떨어져 물이 원활히 배수되지 못하고 표층부의 함수비가 증가하여 지반의 질퍽임 현상이 많이 나타나고 있다. 본 연구는 강우시 배수가 불량하여 유적지에 분포하는 문화재의 기초 뿐만 아니라 상부구조물에도 큰 영향이 예상되어 배수불량의 원인을 파악하고자 하였다. 연구방법 : 현장에서 각종 지반조사 및 현장투수시험 그리고 지하수 모니터링을 통해 그 상관성을 분석하여 매립층의 배수에 대한 불량 원인을 파악하였다. 연구결과 : 본 연구결과 배수불량 원인은 부지내 지하수위가 매우 얕은 심도에 형성되어 있으며, 지표부 및 매립층의 토질은 투수성이 불량한 상태로 강우시 지하로 지표수가 침투되기에는 매우 부적합한 수리지질학적 여건임을 확인할 수 있었다.

변동유형 분석법을 이용한 해수침투 관측망 자료 평가 (Evaluation of Long-term Data Obtained from Seawater Intrusion Monitoring Network using Variation Type Analysis)

  • 송성호;이진용;이명재
    • 한국지구과학회지
    • /
    • 제28권4호
    • /
    • pp.478-490
    • /
    • 2007
  • 우리나라 서, 남해안에 지하수의 해수침투 현상을 관측하기 위해 설치된 관측망 자료를 이용하여, 해당지역별 대수층을 통한 해수침투의 유형을 분석하였다. 분석에 이용된 관측정은 25개 해안지역 소유역의 총 45개 암반관정으로, 지하수위, 수온, 전기전도도를 대상으로 기본통계분석, 상관성 분석 및 변동유형 분류를 수행하였다. 분석 결과 지하수위의 경우 강우 영향을 받거나 양수에 의한 수위강하가 나타나는 관측정에서 큰 폭으로 변동하고 있다. 지하수온은 대부분의 경우 변동폭이 $0.2^{\circ}C$ 이내로 안정적인 특징을 보여주고 있으며, 전체적으로 평균 온도가 $15^{\circ}C$ 이상으로 나타났다. 전기전도도의 경우 상대적으로 변동폭이 크고 불규칙한 특징을 가지고 있으며, 평균값이 $2,000\;{\mu}S/cm$ 이내의 관측정이 28개, $10,000\;{\mu}S/cm$를 초과하는 관측정은 9개소로 나타났다. 교차상관도 분석에 의하면, 지하수위는 강우의 영향을 받아 변동하는 형태가 많았지만 수온과 전기전도도는 상대적으로 강우의 영향이 없는 것으로 나타났다. 조석의 경우에는 일부 관측정에서 강우에 의한 영향보다 높은 교차상관도가 나타났다. 본 연구에서는 장기관측자료를 변동형태에 따라 정상형, 추세형, 주기형, 충동형, 계단형, 경사형 등 6가지로 분류하였다. 지하수위의 경우 강우나 양수의 영향을 받는 충동형이 가장 많은 73.3%이며, 조석의 영향은 13.4%에 해당되었다. 지하수온의 경우 변동폭이 일정한 정상형태가 51.2로 가장 높게 나타났으며, 강우나 양수에 의한 충동형이 26.7%에 해당되었다. 전기전도도의 경우는 지하수위나 지하수온과 달리 추세형, 계단형, 경사형 등의 변동형태가 우세한 것으로 나타났다. 전체적으로 동일한 해안지역에 설치된 관측정별로 관측자료의 변동 특성이 상이한 경우가 나타남에 따라, 향후 각 소유역별로 관측정 자료의 정기적인 변동 경향성을 분석하는 것이 필요하다.

전남 해안 LPG 저장공동 유출수와 주변 지하수의 수질특성 (Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern of Jeonnam)

  • 이진용;최미정;김현중;조병욱
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권4호
    • /
    • pp.33-44
    • /
    • 2009
  • LPG를 저장하는 지하공동의 수장막 시스템은 고압의 가스가 공동 밖으로 새어나가지 못하도록 원활한 지하수의 흐름과 안정적인 지하수두 유지가 필수적이다. 본 연구에서는 전남 여수 LPG공동의 유출수 및 주변 지하수의 수질특성을 파악하기 위하여 2007년 2월, 5월, 8월, 10월에 걸쳐 시료채취, 현장측정 및 실내 수질분석을 실시하였다. 현장 측정 결과 pH는 약산성에서 중성으로 나타났고 10월로 갈수록 증가하는 경향을 나타내었다. 전기전도도는 소금적치장과 인접한 관정의 경우 $10.47{\sim}38.50\;mS/cm$로 매우 높게 나타났다. 용존산소는 $0.20{\sim}8.74\;mg/L$로 매우 넓은 범위를 보였고, 산화환원전위는 평균 159 mV로 비교적 산화환경임을 나타냈다. 또 $Fe^{2+}$, $Mn^{2+}$의 농도는 대부분 3 mg/L 미만으로 나타났다. 수질유형은 유출수의 경우 4차례 모두 Na-Cl type로 나타났으나 지하수의 경우 소금적치장 인접 관측정은 Na-Cl type으로 높은 TDS를 보였다. 다른 지하수 관측정은 전형적인 $Ca-HCO_3$ type으로 나타났다. 미생물 분석결과 호기성세균의 수가 $573{\sim}39,520\;CFU/mL$로 비교적 높게 검출되었다. 본 연구에서 수리화학 및 미생물학적 특성을 분석한 결과 지하수와 유출수는 여수 저장공동의 운영에 있어서 큰 문제를 일으키지 않을 것으로 사료된다. 그러나 미생물 증식의 제어와 수리적 안정성을 유지하기 위해서는 지속적인 모니터링이 요구된다.

인천 해안 저장공동 유출수 및 주변 지하수의 수질특성 (Characteristics of Seepage Water and Groundwater in Incheon Coastal LPG Storage Cavern)

  • 조윤주;이진용;최미정;조병욱
    • 지질공학
    • /
    • 제20권1호
    • /
    • pp.1-12
    • /
    • 2010
  • 본 연구에서는 인천 해안 LPG공동의 수리화학적 안정성을 평가하기 위해 공동 유출수 및 주변 지하수에 대한 수리지구화학적 및 미생물학적 특성을 평가하였다. 수질특성을 파악하기 위하여 2007년 2월, 5월, 8월, 10월에 걸쳐 시료채취 및 수질분석을 실시하였다. 프로판공동 지하수의 경우 pH는 8.1~12.4의 높은 값을 보였으며 이는 공동건설 및 관측정설치에 사용된 시멘트 그라우팅 물질의 용해영향으로 사료된다. 전기전도도는 시료채취 시기별로 큰 차이를 보였으며, 음의 산화환원전위는 유출수 및 지하수가 환원환경에 있음을 지시하였다. 수질분석결과 유출수 및 지하수의 수질유형은 모두 Na-Cl type으로 나타났으며 이는 해수의 영향으로 판단된다. 호기성세균, 혐기성세균, 점액질세균, 황산환원세균 모두 500 CFU/mL 미만으로 낮은 값을 보였으며 급격한 미생물 성장은 관찰되지 않았다. 현재로선 공동 운영에 지장을 주는 특이적 수리화학적 현상이 발견되지는 않았으나 지속적인 모니터링이 필요하다.