• Title/Summary/Keyword: monitoring and verification

Search Result 460, Processing Time 0.032 seconds

Development of Exercise Analysis System Using Bioelectric Abdominal Signal (복부생체전기신호를 이용한 운동 분석 시스템 개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.183-190
    • /
    • 2012
  • Conventional physical activity monitoring systems, which use accelerometers, global positioning system (GPS), heartbeats, or body temperature information, showed limited performances due to their own restrictions on measurement environment and measurable activity types. To overcome these limitations, we developed a portable exercise analysis system that can analyze aerobic exercises as well as isotonic exercises. For bioelectric signal acquisition during exercise, waist belt with two body contact electrodes was used. For exercise analysis, the measured signals were firstly divided into two signal groups with different frequency ranges which can represent respiration related signal and muscular motion related signal, respectively. After then, power values, differential of power values, and median frequency values were selected for feature values. Selected features were used as inputs of support vector machine (SVM) to classify the exercise types. For verification of statistical significance, ANOVA and multiple comparison test were performed. The experimental results showed 100% accuracy for classification of aerobic exercise and isotonic resistance exercise. Also, classification of aerobic exercise, isotonic resistance exercise, and hybrid types of exercise revealed 92.7% of accuracy.

The Comparative Study on Incentive System for Integrated Design of Low-Energy Buildings (저에너지건물 통합설계 인센티브 체계 비교 연구)

  • Lee, Byungyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.129-139
    • /
    • 2016
  • The purpose of this paper was to comparatively investigate the efficient building incentives in Korea and foreign countries and to seek strategies to enhance low energy building integrated design market infrastructure in Korea. The structure of incentive policies were composed of four main component: 1) types of financial aids and beneficiaries, 2) energy performance criteria and verification methods, 3) supports for low energy building integrated design, and 4) funding sources for incentive programs. Every overseas incentive program has adopted a design team incentive along with building owners incentive and the range of target buildings have been extended from new construction to remodeling projects. The main system of the program is the performance standard through which projects were investigated and the level of incentive are decided. Initially, the integrated performance has been investigated through simulation methods, but the construction performance evaluation and energy monitoring methods are emerging. In addition, the direct support and educational support for integrated design has been provided to enhance the foundation of relative markets. Financial funding is also a key component of the program and more aggressive funding strategies have been adopted.

A Study on a Development of Automated Measurement Sensor for Forest Fire Surface Fuel Moistures (산불연료습도 자동화 측정센서 개발에 관한 연구)

  • YEOM, Chan-Ho;LEE, Si-Young;PARK, Houng-Sek;WON, Myoung-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.917-935
    • /
    • 2020
  • In this study, an automated sensor to measure forest fire surface fuel moistures was developed to predict changes in the moisture content and risk of forest fire surface fuel, which was indicators of forest fire occurrence and spread risk. This measurement sensor was a method of automatically calculating the moisture content of forest fire surface fuel by electric resistance. The proxy of forest fire surface fuel used in this sensor is pine (50 cm long, 1.5 cm in diameter), and the relationship between moisture content and electrical resistance, R(R:Electrical resistance)=2E(E:Exponent of 10)+13X(X:Moisture content)-9.705(R2=0.947) was developed. In addition, using this, the software and case of the automated measurement sensor for forest fire surface fuel moisture were designed to produce a prototype, and the suitability (R2=0.824) was confirmed by performing field monitoring verification in the forest. The results of this study would contribute to develop technologies that can predict the occurrence, spread and intensity of forest fires, and are expected to be used as basic data for advanced forest fire risk forecasting technologies.

Land Cover Classification Using UAV Imagery and Object-Based Image Analysis - Focusing on the Maseo-myeon, Seocheon-gun, Chungcheongnam-do - (UAV와 객체기반 영상분석 기법을 활용한 토지피복 분류 - 충청남도 서천군 마서면 일원을 대상으로 -)

  • MOON, Ho-Gyeong;LEE, Seon-Mi;CHA, Jae-Gyu
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • A land cover map provides basic information to help understand the current state of a region, but its utilization in the ecological research field has deteriorated due to limited temporal and spatial resolutions. The purpose of this study was to investigate the possibility of using a land cover map with data based on high resolution images acquired by UAV. Using the UAV, 10.5 cm orthoimages were obtained from the $2.5km^2$ study area, and land cover maps were obtained from object-based and pixel-based classification for comparison and analysis. From accuracy verification, classification accuracy was shown to be high, with a Kappa of 0.77 for the pixel-based classification and a Kappa of 0.82 for the object-based classification. The overall area ratios were similar, and good classification results were found in grasslands and wetlands. The optimal image segmentation weights for object-based classification were Scale=150, Shape=0.5, Compactness=0.5, and Color=1. Scale was the most influential factor in the weight selection process. Compared with the pixel-based classification, the object-based classification provides results that are easy to read because there is a clear boundary between objects. Compared with the land cover map from the Ministry of Environment (subdivision), it was effective for natural areas (forests, grasslands, wetlands, etc.) but not developed areas (roads, buildings, etc.). The application of an object-based classification method for land cover using UAV images can contribute to the field of ecological research with its advantages of rapidly updated data, good accuracy, and economical efficiency.

Validity Assessment of Self-reported Smoking Status: Results from the Korean National Environmental Health Survey (KoNEHS) 2009-2011 (흡연상태에 관한 자가보고 설문의 타당도 평가: 제1기(2009-2011) 국민환경보건기초조사 자료 분석)

  • Choi, Wookhee;Park, Kyung Hwa;Kim, Hyun Jeong;Ryu, Jungmin;Yu, Seung Do;Choi, Kyunghee;Kim, Suejin
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.492-501
    • /
    • 2014
  • Objectives: The purpose of this study was to assess the validity of self-reported cigarette smoking status and investigate factors associated with the accuracy self-reported and measured urinary cotinine in Korean adults. Methods: We used data from the $1^{st}$ Korean National Environmental Health Survey (2009-2011) among adults aged ${\geq}19$ years (N=6,246). The survey examined self-reported smoking status, and urinary cotinine was regarded as the biomarker of exposure to tobacco smoke. Urinary cotinine was analyzed using a gas chromatography-mass spectrometry (GC/MS) and data analysis was conducted using IBM SPSS version 20.0, which uses the sample weight and calculates variance estimates to adjust for the unequal probability of selection into the survey. Results: We calculated a cut-off point (53.3 ug/L) by using a ROC (Receiver Operating Characteristic) curve. The smoking prevalence was 24.6% based on self-reported data and 28.2% based on urinary cotinine concentrations. When we assessed the agreement between self-reported and urinary cotinine, we found an average agreement of 97.7% among self-reported smokers and 94.5% among self-reported non-smokers. Among self-reported smokers, factors affected the discrepancy were age, household economic status and average number of cigarettes smoked per day. On the other hand, gender, former smoking experience, and exposure to SHS (second hand smoke) were associated with discrepancies among self-reported non-smokers. Conclusion: These results suggest that self-reported data on smoking status provide a valid estimate of actual smoking status. In future research, we will conduct a continuous monitoring study for reliability verification of the data to reduce potential interpretation errors.

A Study on the Smart Home Safety Management System Based on NIALM (NIALM 기반의 스마트 홈 안전관리시스템에 관한 연구)

  • Jeong, Han-Sang;Sung, Kyung-Sang;Oh, Hae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.55-63
    • /
    • 2017
  • Due to spatial problems and system size,conventional measurement methods used to acquire the information needed for existing electrical energy and management have been limited to new buildings or areas where replacement is possible. This electric load management method is problematic when applying it to energy and safety management of vulnerable areas or existing homes or offices. The problem with installing a measurement module in every branch is that the system is too large. Even if the measurement module is installed, the type of load is not recognized, and efficient management is not performed. In particular, it is very difficult to apply it to traditional markets and backward facilities in Korea. In this paper, we apply NIALM technology and arc detection technology to solve these problems and verify the feasibility of NIALM for normal arc generation. Also, based on the verification results, we propose a new smart home safety management system that can effectively manage electrical safety and that can be applied to conventional market and existing home safety management systems. The proposed system conducts a comparative performance test with an existing safety management system. In addition, it achieves 95% or more load recognition for four loads, which is impossible in 40% of the existing systems, and the arc detection function was confirmed.

Validity of Linear Combination Approach based on Net Damping Analysis of Cable-Damper System (케이블-댐퍼 시스템의 전체감쇠비 해석을 통한 선형조합 접근법의 유효성)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.467-475
    • /
    • 2009
  • Existing studies have suggested Universal Curve only for supplemental damping by damper. Therefore net damping has been determined by means of arithmetic summation between intrinsic, aero-damping of cable and supplemental damping of damper. However linear combination approach by means of the arithmetic summation is not enough theoretical background. So validity of this approach should be verified in order to design adequate cable-damper system by engineers. This study establishes governing differential equation which can consider intrinsic, aero-damping and supplemental damping as well. And also analysis method is solved by combination of muller method and successive iteration method. Consequently, this study succeeds in verification for validity of linear combination approach. As a result of this study, linear combination approach is limitedly effective in case of low stiffness and optimum damping coefficient of damper, short distance from support to damper, lower vibration mode, low aero-damping, and normal windy environment. Whereas this study will be effective in case of opposite conditions, and existing studies or linear combination approach occur to further error. Meaning of this study presents exact solution for net damping of cable-damper system, and verifies linear combination approach by means of the analysis method. In the future, if monitoring of optimum damping coefficient of a damper against aero-damping is feasible on time, algorithm of this study will be available for control of cable and semi-active damper system such as magneto-rheological damper.

The Application of HACCP System to Soybean Curd and Its Effectiveness (두부류에 대한 HACCP 적용 및 성과)

  • Park, Wan-Hee;Lee, Sung-Hak
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.4
    • /
    • pp.202-210
    • /
    • 2003
  • This study aims at making a HACCP(Hazard Analysis Critical Control Point)plan to be applied to soybean curd and verifing its effectiveness. First, we develped a general model of HACCP according to the guidelines of Codex (FAO/WHO). And we applied the model to 4 soybean curd workshops for 3 months. The HACCP model is composed of these procedures; HACCP team organization, production description, work flow chart, hazatd analysis, CCP (critical control point) decision, CL (critical limit) establishment, monitoring method decision, correction, verification and documentation. CCP were selection procedure and refrigeration procedure in non-wrapped soybean curd. CCP were selection procedure, heat-sterilizing and refrigeration in wrapped soybean curd. The result of bacterial experiment after apling the model for 3 months, the bacterial numbers of soybean curd box, wrapper, and soybean curd production were lower after appling than before appling, the model. We could verify that the appications of the HACCP model were effective to the soybean curd workshops.

A Development of Fluxgate Sensor-based Drone Magnetic Exploration System (플럭스게이트 센서 기반 드론 자력탐사 시스템 개발)

  • Noh, Myounggun;Lee, Seulki;Lee, Heuisoon;Ahn, Taegyu
    • Geophysics and Geophysical Exploration
    • /
    • v.23 no.3
    • /
    • pp.208-214
    • /
    • 2020
  • In this study, we have developed a drone magnetic exploration system (proto-type) using a fluxgate magnetic sensor. Hardware of the system consists of a fluxgate magnetometer, an inertial measurement unit (IMU), a GPS, and a communication module. And we have developed monitoring software, which enables it to transmit the measured data to the ground control system (GCS) in real time. The measured magnetic data are finally saved as 1 Hz data after passing through a notch filter and a band-pass filter. For verification of this system, a preliminary test was conducted to check the magnetic responses of a magnetic object first, then the field test was carried out in two iron mines. We tested the developed system on the field test in Pocheon, Gyeonggi and Jeongseon, Gangwon. The magnetic data from the developed drone system was very similar to those from unmanned airship system developed by Korea Institute of Geoscience and Mineral Resources (KIGAM). As a result, preliminary experiment and field test have demonstrated that this system is applicable for outdoor aeromagnetic exploration. It requires more studies to improve filter function and instrument performance to minimize noise in the future.

Development of the Critical Pathway for Cesarean Section Patient (제왕절개술 환자를 위한 Critical Pathway 개발)

  • Chung Kyung-Hee;Jang Keum-Seung
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.4 no.1
    • /
    • pp.66-80
    • /
    • 1998
  • With the opening of healthcare market, the health care environment in Korea is anticipating a drastic change. In this Internationally open market environment, it is necessary to introduce a systematic health care plan and DRG system which offer qualitative medical services as well as reduced cost. Purpose of this study is to develop and test the critical pathway for Cesarean section patient in the way to be possible the integrated inpatient management. It was adopted the process of six phases to develop the critical pathway as the theoretical framework implemented by Johns Hopkins Hospital, Maryland, U.S.A. In the first phase, make a selection of diagnosis/procedures to develop. In the second phase, organize a development team consisted of eight expertises working in maternity nursing area. In the third phase, analyze the overall medical service offered to patient through review medical records and decided the service content and the implementation period for the Cesarean section patient. In the forth phase, make out a preliminary critical pathway after verification of expert group on content validity. In the fifth phase, validity operate to ten Cesarean section patients to test implementation in practice by using the preliminary critical pathway, In the sixth phase, defined the final critical pathway. The result of this study was as follows. 1. There were classified 8 categories as monitoring/assesment, treatment, medication, activity, diet, test, consult, education/discharge plan for vertical axis and showed hospital stayed from admission to discharge for horizontal axis of critical pathway through analysis 68 Cesarean section patients medical records. 2. After critical review 68 medical records to make out a preliminary critical pathway, hospital stays for horizontal axis were showed 6 days, mean hospital stays were 7.5 days, 2.1 days were to be taken operation after admission and 4.2 days were stayed until discharge after operation. 3. After making out a questionare in 90 items of a medical service content of eight categories and verifying the content validity of expertises, the 85 items of the preliminary critical pathway were selected by expertises agreement over 88% and modified or deleted 5 items showing agreement below 75%. 4. After verifying a validity to 10 patients for 4 weeks, hospital stays were 5.9 days. There were deleted 1 item and modified or supplemented the 9 items of the 10 items.

  • PDF