• Title/Summary/Keyword: monitor unit

Search Result 340, Processing Time 0.024 seconds

A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field (다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구)

  • Kim Joo-Ho;Lee Sang-Gyu;Shin Hyun-Kyung;Lee Suk;Na Soo-Kyung;Cho Jung-Hee;Kim Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Purpose : Many authors have been introduced field in field technique and 3-D conformal radiotherapy that increased the tumor dose as well as decreased the dose of abutting critical organ. These technique have multiple beam direction and small beam segments even below 10 MU(monitor unit)for each field. we have confirmed the influence of low MU on dose output and beam stability. Materials and Methods : To study the dose output, the dose for each field was always 90MU, but it divided into different segment size: 1, 2, 3, 5, 10, 15 segments, 90, 45, 30, 18, 9, 6 MU the measurements were carried out for X-ray energy 4 MV, 6 MV, 10 MV of three LINAC(Varian 600C, 2100C, 2100C, 2100C/D), in addition each measurement was randomly repeated three times for each energy. To study the field symmetry and flatness, X-omat V films were irradiated. After being developed, films were scanned and analyzed using densitometer. Results : Influence of low MU on dose is slightly more increase output about $1.2{\sim}2.9%$ in cGy/mu than 90MU, but may not changed beam quality(flatness or symmetry), Output stability depends on dose rate(PRF)rather than beam energy, field size. Conclusion : Presented result are under the limits(out put<3%, flatness<${\pm}3%$, symmetry<2%). The 3 accelerators are safe to use and to perform conformal radiotherapy treatments in small segments, small MU around 10MU. but Even if the result presented here under the limits, continuous adjustments and periodic QA should be done for use of small MU

  • PDF

Blood transcriptome resources of chinstrap (Pygoscelis antarcticus) and gentoo (Pygoscelis papua) penguins from the South Shetland Islands, Antarctica

  • Kim, Bo-Mi;Jeong, Jihye;Jo, Euna;Ahn, Do-Hwan;Kim, Jeong-Hoon;Rhee, Jae-Sung;Park, Hyun
    • Genomics & Informatics
    • /
    • v.17 no.1
    • /
    • pp.5.1-5.9
    • /
    • 2019
  • The chinstrap (Pygoscelis antarcticus) and gentoo (P. papua) penguins are distributed throughout Antarctica and the sub-Antarctic islands. In this study, high-quality de novo assemblies of blood transcriptomes from these penguins were generated using the Illumina MiSeq platform. A total of 22.2 and 21.8 raw reads were obtained from chinstrap and gentoo penguins, respectively. These reads were assembled using the Oases assembly platform and resulted in 26,036 and 21,854 contigs with N50 values of 929 and 933 base pairs, respectively. Functional gene annotations through pathway analyses of the Gene Ontology, EuKaryotic Orthologous Groups, and Kyoto Encyclopedia of Genes and Genomes (KEGG) databases were performed for each blood transcriptome, resulting in a similar compositional order between the two transcriptomes. Ortholog comparisons with previously published transcriptomes from the $Ad{\acute{e}}lie$ (P. adeliae) and emperor (Aptenodytes forsteri) penguins revealed that a high proportion of the four penguins' transcriptomes had significant sequence homology. Because blood and tissues of penguins have been used to monitor pollution in Antarctica, immune parameters in blood could be important indicators for understanding the health status of penguins and other Antarctic animals. In the blood transcriptomes, KEGG analyses detected many essential genes involved in the major innate immunity pathways, which are key metabolic pathways for maintaining homeostasis against exogenous infections or toxins. Blood transcriptome studies such as this may be useful for checking the immune and health status of penguins without sacrifice.

Development of Methodology for Measuring Water Level in Agricultural Water Reservoir through Deep Learning anlaysis of CCTV Images (딥러닝 기법을 이용한 농업용저수지 CCTV 영상 기반의 수위계측 방법 개발)

  • Joo, Donghyuk;Lee, Sang-Hyun;Choi, Gyu-Hoon;Yoo, Seung-Hwan;Na, Ra;Kim, Hayoung;Oh, Chang-Jo;Yoon, Kwang-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.15-26
    • /
    • 2023
  • This study aimed to evaluate the performance of water level classification from CCTV images in agricultural facilities such as reservoirs. Recently, the CCTV system, widely used for facility monitor or disaster detection, can automatically detect and identify people and objects from the images by developing new technologies such as a deep learning system. Accordingly, we applied the ResNet-50 deep learning system based on Convolutional Neural Network and analyzed the water level of the agricultural reservoir from CCTV images obtained from TOMS (Total Operation Management System) of the Korea Rural Community Corporation. As a result, the accuracy of water level detection was improved by excluding night and rainfall CCTV images and applying measures. For example, the error rate significantly decreased from 24.39 % to 1.43 % in the Bakseok reservoir. We believe that the utilization of CCTVs should be further improved when calculating the amount of water supply and establishing a supply plan according to the integrated water management policy.

Design and Implementation of a Radio Telemetry System to Monitor the Deep Body Temperature of Broilers (육계의 체온 관찰을 위한 무선 원격측정 시스템 설계 및 구현)

  • Yang, Hyun-Ho;Min, Won-Gi;Bae, Yeong-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.81-86
    • /
    • 2008
  • A radio telemetry system was fabricated to continuously measure the deep body temperature (DBT) of broilers as an effort to monitor the occurrences of possible poultry diseases. It was shown that the DBT of broilers could be measured with an accuracy of ${\pm}0.1^{\circ}C$. Daily fluctuation of DBT in case of a 40 days old broiler was evaluated. To develop a system which can control the environment of poultry housing in real time based on DBT measurements, we proposed the design criteria of a dedicated receiver unit.

Factors influencing Video Display Terminal Syndrome in Clinical Nurses (임상간호사의 영상표시단말기 증후군 및 영향요인)

  • Kwon, Yunhee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.22 no.4
    • /
    • pp.485-494
    • /
    • 2016
  • Purpose: The present research is a descriptive study aimed at understanding clinical nurses' Video display terminal (VDT) syndrome and identifying the factors that affect their VDT syndrome. Methods: Data were collected from 239 clinical nurses working in two metropolitan cities. Research tools included subject's VDT syndrome assessing musculoskeletal, ophthalmic, dermal, psychiatric, and whole body syndromes. The data were analyzed using frequency analysis, average and standard deviation, t-test, One-way ANOVA, and multiple regression analysis with the SPSS/WIN 20.0 program. Results: The subjects' VDT syndrome score was 1.34 out of 5. There were significant differences in participating subjects' VDT syndrome, hospital's size, working unit, health status, diagnosis of illness, having an Order Communication System (OCS), having an Electronic Medical Record (EMR) System, continuous VDT working for more than one hour, break time during VDT use, VDT use time, comfort of the chair, adjustability of the height of the chair, size of the VDT's desk, distance between the monitor and the user's eyes, resolution of the monitor, and frequency of eye exercise during VDT use. According to the research, influencing factors on VDT syndrome in clinical nurses included size of the VDT's desk, frequency of eye exercise during VDT use, having an EMR system, break time during VDT use, diagnosis illness, and having an OCS' system. Conclusion: The findings from this study can be used as a basis for future VDT syndrome prevention education and programs for clinical nurses.

Personal Monitor & TV Audio System by Using Loudspeaker Array (스피커 배열을 이용한 개인용 모니터와 TV의 오디오 시스템)

  • Lee, Chan-Hui;Chang, Ji-Ho;Park, Jin-Young;Kim, Yang-Hann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.701-710
    • /
    • 2008
  • Including a TV set and a monitor, personal audio system is raising a great interest. In this study, we applied a method to make a good bright zone around the user and dark zone to other region by maximizing the ratio of sound energy between the bright and dark zone. It has been well known as acoustic contrast control. We have attempted to use a line loudspeaker array system to localize the sound in our listening zone. It depends on the size of the zone and array parameters, for example, array size, loudspeaker unit spacing, wave length of sound. We have considered these parameters as spatial variables and studied the effects. And we have found that each spatial variable has its own characteristic and shows very different effect. Genetic algorithms are introduced to find out the optimum value of spatial variables. As a result, we can improve the result of the acoustic contrast control by optimum value of spatial variables.

The effects of short persistent CCFL in Blinking Back Light Unit to reduce blur on TFT-LCD (단잔광특성의 CCFL을 사용한 Blinking Back Light의 구현과 화질 평가)

  • Park, Jeong-Kuk;Han, Jeong-Min;Bae, Kyung-Woon;Kim, Seo-Yoon;Kim, Yun-Ho;Lim, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.160-164
    • /
    • 2003
  • LCD를 TV 향으로 적용하기 위해서는 몇 가지 해결해야만 하는 문제가 있으며, 이중 하나가 동화상 재생시에 발생하는 잔상현상의 해결이다. LCD는 기존의 CRT와 같은 불연속 자발광 소자가 아니라, 연속수광소자로서, 잔상현상이 치명적인 약점으로 나타난다. 기종의 Monitor 대응품에서는 실제로 Monitor를 통해서 사용자가 관찰하는 이미지 정보가 정지화상 중심으로 구성되어 있기 때문에 문제가 되지 않았으나, TV의 경우 연속적인 동화상만을 취급하고 있어, 잔상현상의 해결 없이는 TV 향 제품에 적용할 수 없다. 따라서 본 연구에서는 잔상현상을 근본적으로 없애기 위해서 LCD를 CRT와 같이 불연속적의 분절적 이미지로 구동하는 방법을 실험하였으며, VIDEO 입력 신호에 대해서 16.7msec의 1Frame을 기준으로 점등 구간과 비점등 구간을 6:4로 나누어 BL(Back Light)을 점멸하는 방법을 구현하였다. 또한 종래의 CCFL(cold Cathod Flourescent Lamp)로는 점멸 속도에 대한 대응이 불가하므로, 이를 해결하기 위해서 광원의 형광체에 대해서 잔광시간특성의 개선도 동시에 실시하였다. 실험 결과 육안 및 사진촬영에서 잔상없는 화면을 얻을 수 있었으며, 응답파형 측정 결과 CRT 측정시와 마찬가지로 분절적인 이미지의 생성이 가능한 것을 알 수 있었다.

  • PDF

High Brightness Back Light Unit Using the L-Shape Lamp (L 자형 램프를 사용한 고휘도 Back Light 의 구현)

  • Han, Jeong-Min;Park, Jeong-Kuk;Ahn, Jun-Seong;Bae, Kyung-Woon;Kim, Seo-Yoon;Kim, Yun-Ho;Lim, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.169-172
    • /
    • 2003
  • 기존의 Monitor 대응 LCD 에서 TV 대응 LCD로의 개발에 있어서 특성 개선은 다각도로 진행되고 있으나, 무엇보다도 휘도 특성의 개선이 요구된다. TV 대응 LCD Panel 은 Monitor 대응 제품에 비해서 일반적으로 해상도가 낮으므로, 투과율면에서 장점은 있으나, 현재의 B/L 구조로는 만족할만한 성능을 낼 수 없는 상황이다. 고휘도 BL(Back Lignt)를 위해서 EEFL(External Electrode Fluorescent Lamp) 혹은 CCFL 의 복수 사용을 전제로 한 직하방식에 대한 개발 검토가 활발히 이루어지고 있으나, 직하방식에 의한 고휘도화는 램프수의 증가에 따른 인버터의 기구적, 전기적 사양의 증가를 필요로 하며, LCD Module전체의 두께가 증가되는 문제를 가지고 있다. 본 연구에서는 L-Shaped 램프를 적용하여 기본의 기구적인 사양 및 전기적인 사양을 유사하게 유지함과 동시에, 고휘도화를 실현하여 TV 대응 수준을 확보하였으며, lamp를 floating구동하여 램프편측 전압 500V를 사용하면서 655 nit의 휘도를 달성하였다.

  • PDF

Intrabed Networks in a Patient Monitoring System (환자 모니터링 시스템에서의 통신 방식(I) : 인트라베드 통신망)

  • 우응제;박승훈;김경수;최근호;김승태;이희철;서재준;김형진
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.373-380
    • /
    • 1997
  • In this paper, we describe the intrabed network in a patient monitoring system we developed The intrabed network handles data communication between the main unit of a bedside patient monitor and parameter modules plugged in it. We designed the intrabed network based on RS-485 and HDLC protocol with 1 Mbps data rate. Message exchanges are implemented based on three data structures of packet frame. and stream. We present the specification and the performance of the data communication network for the developed patient monitor.

  • PDF

Implement of Watt-Hour Meter Monitoring System by Internet Map Based GUI using Power Line Communication (전력선 통신을 이용한 인터넷 맵 연동 전자계량기 모니터링 시스템 구현)

  • Park, Keun-Soo;Lee, Young-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.10
    • /
    • pp.1435-1441
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system applying a Power Line Communication (PLC) MODEM and a Data Concentrator Unit (DCU) which can apply to Internet map based Graphical User Interface (GUI). The PLC MODEM is profitable by saving the cost of installing dedicated wiring, and Internet map GUI also is able to contribute an easy access to monitoring system for non export users. This system makes it possible to monitor the amount of electricity of previous/ current month metering data via Internet mapping service. The implement system can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.