• 제목/요약/키워드: monitor function

검색결과 484건 처리시간 0.024초

자기진단 CPGFRP의 파괴예측기능 평가를 위한 콘크리트 적용실험 (Evaluation of Fracture Detection Function for the Concrete by Self-Diagnosis CPGFRP)

  • 최현수;박진섭;정민수;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.27-31
    • /
    • 2003
  • To maintain serviceability of concrete structure more than proper it is necessary not only predict service life through periodical monitor but also need monitoring system to recognize optimal time and method for repair. Recently, CPGFRP, replacing some GFRP with CF, is developed and used for monitoring concrete fraction. But dramatic resistance change of CPGFRP is showed below 0.5% strain and it is not small strain in terms of monitoring micro crack in concrete. In other word, monitoring with CF is not suitable in low stress hut hight stress. In this study, we accessed applicable possibility and reliability of CPGFRP composite as monitoring sense that is proved very sensitive to stress through domestic and oversea previous study. CPGFRP composite plays a role in specimen like steel and increases flexural strength. CPGFRP composite shows resistance increasement in micro crack. In particular, CPUFRP is more sensitive than strangage in low stress. Resistance change ratio curve is very similar to strain curve so sensitivity and reliability is very excellent to monitor concrete fracture.

  • PDF

퍼지제어를 이용한 바이올린 연주 연습 알고리즘 개발 (Development of Violin Self-Training Algorithm using Fuzzy Logic)

  • 민병철;김동한;김윤혁;김기열;박종국
    • 한국지능시스템학회논문지
    • /
    • 제19권4호
    • /
    • pp.550-555
    • /
    • 2009
  • 바이올린은 아름다운 음색과 풍부한 표현력으로 현악기 가운데 중요한 위치를 차지하고 있다. 그러나 바이올린 연주를 처음 시작하는 초보자들에게는 정확한 연주를 하기가 쉽지 않다. 이는 연주 시 활의 힘과 활을 켜는 속력 그리고 활과 현과의 접촉점 및 현을 집는 손가락 위치의 부정성에서 기인된다. 따라서 본 논문에서는 이 점을 해결하기 위해 전문 바이올리니스트의 운궁법에 대한 데이터베이스를 사전 구축하고, 연주자가 실제 바이올린을 켤 때 얻어지는 데이터를 구축된 데이터베이스와 실시간으로 비교하고 그 결과를 퍼지 Logic을 사용한 성능평가함수로 성능평가를 한 후 Monitor상에 결과를 보이도록 하였다.

자기진단 CPGFRP의 파괴예측기능 평가를 위한 콘크리트 적용실험 (Evaluation of Fracture Detection Function for the Concrete by Self-Diagnosis CPGFRP)

  • 최현수;박진섭;정민수;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.27-31
    • /
    • 2003
  • To maintain serviceability of concrete structure more than proper it is necessary not only predict service life through periodical monitor but also need monitoring system to recognize optimal time and method for repair. Recently, CPGFRP, replacing some GFRP with CF, is developed and used for monitoring concrete fraction. But dramatic resistance change of CPGFRP is showed below 0.5% strain and it is not small strain in terms of monitoring micro crack in concrete. In other word, monitoring with CF is not suitable in low stress but hight stress. In this study, we accessed applicable possibility and reliability of CPGFRP composite as monitoring sense that is proved very sensitive to stress through domestic and oversea previous study. CPGFRP composite plays a role in specimen like steel and increases flexural strength. CPGFRP composite shows resistance increasement in micro crack. In particular, CPGFRP is more sensitive than strangage in low stress. Resistance change ratio curve is very similar to strain curve so sensitivity and reliability is very excellent to monitor concrete fracture.

  • PDF

학교건물의 노후화에 따르는 개축 판정에 관한 모델의 정립 (School-Building Remodelling Model using Discriminant Analysis - A Case Study for Class Rooms in School Building -)

  • 민창기
    • 교육시설
    • /
    • 제4권4호
    • /
    • pp.29-41
    • /
    • 1997
  • The objective of this paper is to construct a model to be used in deciding whether to repair or rebuild school buildings is depending on their ages and other factors. The theme of this paper is the age is the main variable but other factors such as floor, innerwall, ceiling, door, inner window of the class room, outer window of the class room, inner window of the corridor, outer window of the corridor, middle window between the classroom and the corridor, light, heater, speaker, fire protection sensor, TV monitor, and telephone status would influence the final decisions. This paper employs an experimental case study method. Using the stepwise, statistical, classification method commonly used in discriminant analysis, it evaluates 12,766 rooms of 87 different high schools in Seoul. The result of this study indicates that some critical variables influencing the final decisions are the status of TV monitor, middle window between the classroom and the corridor, light, inner window of the corridor, fire protection sensor, innerwall, speaker utensil, outer window of the class room, and door of the class room. This paper also suggests a linear discriminant function will be used for this kind of studies. Finally the paper recommends policies with respect to the variables and discriminant functions evaluated.

  • PDF

THE UPDATED ORBITAL EPHEMERIS OF DIPPING LOW MASS X-ray BINARY 4U 1624-49

  • LIAO, NAI-HUI;CHOU, YI;HSIEH, HUNG-EN;CHUANG, PO-SHENG
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.593-594
    • /
    • 2015
  • We present our analysis results for an updated orbital ephemeris for the dipping low mass X-ray binary 4U 1624-49, using the light curve collected by the All Sky Monitor (ASM) on board the Rossi X-ray Timing Explorer (RXTE) and the Monitor of All-Sky X-ray Image (MAXI). To make clear dip profiles, the light curve from the ASM and the MAXI were divided into ten 500d segments and four 400d segments for ASM and MAXI light curves, respectively, and folded with the linear ephemeris proposed by Smale et al. (2001). The phases of dip centers were determined by the method adopted from Hu et al. (2008). The phase drift was then fitted with a linear function. We obtained an updated orbital period of 0.869896(1) d and a phase zero epoch of JD 2450088.6618(57). No clear orbital period derivative is detected with a 2-sigma upper limit of $1.4{\times}10^{-6}(yr)^{-1}$ from a quadratic curve fitting of the dip phase evolution.

Damage Monitoring of CP-GFRP/GFRP Composites by Measuring Electrical Resistance

  • Shin, Soon-Gi;Kwon, Yong-Jung
    • 한국재료학회지
    • /
    • 제20권3호
    • /
    • pp.148-154
    • /
    • 2010
  • It is necessary to develop new methods to prevent catastrophic failure of structural material in order to avoid accidents and conserve natural and energy resources. Design of intelligent materials with a self-diagnosing function to prevent fatal fracture of structural materials was achieved by smart composites consisting of carbon fiber tows or carbon powders with a small value of ultimate elongation and glass fiber tows with a large value of ultimate elongation. The changes in electrical resistance of CF-GFRP/GFRP (carbon fiber and glass fiber-reinforced plastics/glass fiber-reinforced plastics) composites increased abruptly with increasing strain, and a tremendous change was seen at the transition point where carbon fiber tows were broken. Therefore, the composites were not to monitor damage from the early stage. On the other hand, the change in electrical resistance of CP-GFRP/GFRP (carbon powder dispersed in glass fiber-reinforced plastics/glass fiber-reinforced plastics) composites increased almost linearly in proportion to strain. CP-GFRP/GFRP composites are superior to CF-GFRP/GFRP composites in terms of their capability to monitor damage by measuring change in electrical resistance from the early stage of damage. However, the former was inferior to the latter as an application because of the difficulties of mass production and high cost. A method based on monitoring damage by measuring changes in the electrical resistance of structural materials is promising for improved reliability of the material.

인터넷을 이용한 CNC 선반의 속도 센서리스 토크감시 (Speed-Sensorless Torque Monitoring on CNC Lathe using Internet)

  • 홍익준;권원태
    • 한국정밀공학회지
    • /
    • 제21권5호
    • /
    • pp.99-105
    • /
    • 2004
  • Internet provides the useful method to monitor the current states of the machine tool no matter where a personnel monitors it. In this paper, a monitoring method of the torque of the machine tool's spindle induction motor using interne is suggested. To estimate the torque accurately, spindle driving system of an CNC lathe is divide into two parts, induction motor part and mechanical part attached to the induction motor spindle. Magnetizing current is calculated from the measured 3 phase currents without speed sensor used to estimate the torque generated by an induction motor. In mechanical part of the system, some of the torque is used to overcome friction and remaining torque is used to overcome cutting force. An equation to estimate friction torque is drawn as a function of cutting torque and rotation speed. Graphical programming is used to implement the suggested algorithm. to monitor the torque of an induction motor in real time and to make the estimated torque monitored on client computers. Torque of the spindle induction motor is well monitored on the client computers in about 3% error range under various cutting conditions.

Along-Track Position Error Bound Estimation using Kalman Filter-Based RAIM for UAV Geofencing

  • Gihun, Nam;Junsoo, Kim;Dongchan, Min;Jiyun, Lee
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권1호
    • /
    • pp.51-58
    • /
    • 2023
  • Geofencing supports unmanned aerial vehicle (UAV) operation by defining stay-in and stay-out regions. National Aeronautics and Space Administration (NASA) has developed a prototype of the geofencing function, SAFEGUARD, which prevents stayout region violation by utilizing position estimates. Thus, SAFEGUARD depends on navigation system performance, and the safety risk associated with the navigation system uncertainty should be considered. This study presents a methodology to compute the safety risk assessment-based along-track position error bound under nominal and Global Navigation Satellite Systems (GNSS) failure conditions. A Kalman filter system using pseudorange measurements as well as pseudorange rate measurements is considered for determining the position uncertainty induced by velocity uncertainty. The worst case pseudorange and pseudorange rate fault-based position error bound under the GNSS failure condition are derived by applying a Receiver Autonomous Integrity Monitor (RAIM). Position error bound simulations are also conducted for different GNSS fault hypotheses and constellation conditions with a GNSS/INS integrated navigation system. The results show that the proposed along-track position error bounds depend on satellite geometries caused by UAV attitude change and are reduced to about 40% of those of the single constellation case when using the dual constellation.

양식장 환경 데이터 모니터링 및 예측 시스템의 설계 (Design of the Environmental Data Monitoring and Prediction System for the Fish Farms)

  • 리타 리자얀티;아쉬위니 카담;아리아 비스마 와휴타마;이본영;황민태
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.178-180
    • /
    • 2021
  • 본 논문에서는 바다 환경의 변화로 인한 양식장의 피해를 막을 수 있도록 양식장의 환경 데이터를 실시간 모니터링하고 기계 학습 기반의 예측 서비스를 제공하는 시스템 설계를 다룬다. 제안 시스템은 양식장의 주요 위치에 수소 농도, 염도, 용존 산소량 그리고 수온을 측정할 수 있는 센서들로 구성되는 사물인터넷 기반의 디바이스 모듈을 설치하며, 이들로 부터 수집한 데이터는 LTE 또는 LoRa 통신 기술을 이용해 클라우드 DB로 전송한 후 웹사이트나 모바일 애플리케이션을 통해 실시간으로 양식장의 환경 데이터 모니터링을 가능하게 한다. 아울러 수집된 데이터를 활용한 기계학습 기반의 예측 기술을 적용해 양식장의 환경 변화에 미리 대비할 수 있도록 하는 기능을 가진다.

  • PDF

Effect of Posture Correction Band on Pulmonary Function in Individuals With Neck Pain and Forward Head Posture

  • Kim, Jae-hyeon;Jeong, Yeon-woo;Kim, Su-jin
    • 한국전문물리치료학회지
    • /
    • 제27권4호
    • /
    • pp.278-285
    • /
    • 2020
  • Background: Individuals with forward head posture (FHP) have neck pain. To correct the FHP, a posture correction band is commonly used. However, we do not know the posture correction band influenced the pulmonary function in individuals with FHP. Objects: This study aimed to elucidate the effects of the posture correction band on the pulmonary function in young adults with neck pain and FHP and to monitor how the pulmonary function changed over time. Methods: Twenty subjects with chronic neck pain and forward head posture were recruited. Subjects performed pulmonary function test four times: before, immediately, and 2 hours after wearing the postural band, and immediately after undressing the postural band. Vital capacity (VC), forced vital capacity (FVC), peak expiratory flow (PEF), and forced expiratory volume at one second (FEV1) were measured. The modified Borg dyspnea scale was used to measure each subject's responses to the posture correction band. The mixed-effect linear regression was used to the effect of the posture correction band over time. Results: There were no significant differences in VC, FVC, PEF, FEV1 values over time (p > 0.05), although all values slightly decreased after applying posture correction band. However, the score of the modified Borg scale significantly changed after wearing the postural bands (p < 0.05), indicating the subject felt discomfort with posture correction band during breathing. Conclusion: Because the posture correction band did not change the pulmonary function over time, but it induces psychological discomforts during breathing in people with FHP. Therefore, this posture correction band can be used for FHP realignment after discussion with the subjects.