• 제목/요약/키워드: molecular magnet

검색결과 21건 처리시간 0.028초

Investigation of the Electronic Structure of Mn12 Molecular Magnet Using Synchrotron Radiation

  • Kang, J.S.;Kim, J. H.;Kim, Yoo-Jin;Jeon, Won-Suk;Jung, Duk-Young;Han, S.W.;Kim, K.H.;Kim, K.J.;Kim, B.S.;Shim, J.H.;Min, B.I.
    • Journal of Magnetics
    • /
    • 제8권4호
    • /
    • pp.149-152
    • /
    • 2003
  • The electronic structure of Mn12-Ac molecular magnet has been investigated using synchrotron radiation. The valence-band photoemission spectroscopy (PES) measurement reveals that Mn 3d states are located near the top of the valence band. The trend in the measured valence-band PES spectra is found to be consistent with that in the calculated local density of states. The Mn 2p x-ray absorption spectroscopy (XAS) measurement provides evidence for the Mn$^{3+}$-Mn$^{4+}$ mixed-valent states.

Detection and Manipulation of Spin state of Single Molecule Magnet: Kondo resonance and ESR-STM

  • Komeda, T.;Isshiki, H.;Zhang, Y.F.;Katoh, K.;Yoshida, Y.;Yamashita, M.;Miyasaka, H.;Breedlove, B.K.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.16-17
    • /
    • 2010
  • Molecular spintronics has attracted attentions, which combines molecular electronics with the spin degree of freedom in electron transport. Among various molecules as candidates of the molecular spintronics, single molecule magnet (SMM) is one of the most promising material. SMM molecules show a ferromagnetic behavior even as a single molecule and hold the spin information even after the magnetic field is turned off. Here in this report, we show the spin behavior of SMM molecules adsorbed on the Au surface by combining the observation of Kondo peak in the STS and ESR-STM measurement. Kondo resonance state is formed near the Fermi level when degenerated spin state interacts with conduction electrons. ESR-STM detects the Larmor frequency of the spin in the presence of a magnet field. The sample include $MPc_2$ and $M_2Pc_3$ molecules ($M\;=\;Tb^{3+}$, $Dy^{3+}$, and $Y^{3+}$ Pc=phthalocyanine) whose critical temperature as a ferromagnet reaches 40 K. A clear Kondo peak was observed which is originated from an unpaired electron in the ligand of the molecule, which is the first demonstration of the Kondo peak originated from electron observed in the STS measurement. We also observed corresponding peaks in ESR-STM spectra. [1] In addition we found that the Kondo peak intensity shows a clear variation with the conformational change of the molecule; namely the azimuthal rotational angle of the Pc planes. This indicates that the Kondo resonance is correlated with the molecule electronic state. We examined this phenomena by using STM manipulation technique, where pulse bias application can rotate the relative azimuthal angle of the Pc planes. The result indicates that an application of ~1V pulse to the bias voltage can rotate the Pc plane and the Kondo peaks shows a clear variation in intensity by the molecule's conformational change.

  • PDF

Synthesis, Structure and Magnetic Properties of Mn12 Single Molecule Magnet Containing 4-(Methylthio)benzoate as Peripheral Ligands

  • Lim, Jin-Mook;Do, Young-Kyu;Kim, Jin-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권7호
    • /
    • pp.1065-1070
    • /
    • 2005
  • $[Mn_{12}O_{12}(O_2CPh-4-SMe)_{16}(H_2O)_4]{\cdot}7CH_2Cl_2$ (1), a new single-molecule magnet complex has been successfully synthesized by substitution of acetate ligand of Mn12ac with 4-(methylthio)benzoic acid. Complex 1 crystallizes into triclinic P$\overline{1}$ with a = 18.321(3) $\AA$, b = 19.011(3) $\AA$, c = 27.230(4) $\AA$, $\alpha$ = 86.973(3)$^{\circ}$, $\beta$ = 76.919(3)$^{\circ}$, $\gamma$ = 87.613(3)$^{\circ}$, and Z = 2. In complex 1, one Mn(III) ion has an abnormal Jahn-Teller elongation axis oriented at an oxide ion. Complex 1 has two out-of-phase ac susceptibility peaks in the 2-4 K and 4-7 K regions. Effective anisotropy energy barrier and pre-exponential factor are $U_{eff}$ = 45.95 K, 1/$\tau$0 = 8.6 ${\times}\;10^9s^{-1}\;for\;{\chi}_M$'' peaks in the lower temperature region and $U_{eff}$ = 59.45 K, 1/$\tau_0$ = 2.2 ${\times}\;10^8\;s^{-1}$ for $\chi_M$'' peaks in the higher temperature region. The parameters of S = 10, g = 1.87, D = -0.40 $cm^{-1}$, and E = 0.00034 $cm^{-1}$ were obtained from the M/N${\mu}_B$ vs. H/T plot of complex 1.

Mn-dimer 분자자성체의 전자구조 및 자기구조 계산 (Electronic and Magnetic Structure Calculations of Mn-dimer Molecular Magnet)

  • 박기택
    • 한국자기학회지
    • /
    • 제24권4호
    • /
    • pp.97-100
    • /
    • 2014
  • 분자자성체 Mn-dimer의 전기구조 및 자기적 성질을 제1원리의 범밀도함수법을 이용하여 계산하였다. 계산 된 결과, 전자구조는 벌크 MnO와 비슷한 Mn 주위의 4개의 산소 원자에 의해 $t_{2g}$, $e_g$ 에너지 준위로 분리되어 있었다. 적은 수의 배위원자로 이 결정장 분리는 작았디. 총에너지 계산에서는 반강자성적 상호작용이 낮은 에너지를 가지고 있었다. 계산 된 $Mn^{+2}$ 원자 사이의 교환상호작용 크기는 다른 Mn-O 분자자성체보다 한 단위 큰 값을 얻었다. 이 원인은 Mn 3d 사이의 직접 상호작용과 Mn-O의 강한 결합으로 인한 초교환상호작용의 결과이다.

영구자석 고속모터의 고조파 분석을 통한 회전자 손실해석 (Calculation of Rotor Loss according to analysis of Harmonics for Permanent Magnet High Speed Motor)

  • 장석명;조한욱;이성호;양현섭;정연호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1042-1044
    • /
    • 2003
  • High speed PM machines are being developed as motor/generators for gas-turbine generator sets in smaller power sizes, and as motors for number of applications including gas compressors, machine tools and turbo molecular pumps. Due to the high peripheral speed of the rotor and the relatively high conductivity of the magnets used, rotor eddy current loss can be substantial. This paper deals with the calculation of rotor eddy-current losse in permanent magnet(PM) high speed motor using the analysis of harmonics.

  • PDF

Soluble Single-Molecule Magnet: Mn12-stearate.

  • 박치동;정둑영
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권6호
    • /
    • pp.611-615
    • /
    • 2001
  • A new polynuclear complex of manganese stearate has been prepared by substitution of acetate with stearic acid. The stearate ion with long alkyl chain was used to isolate molecular $Mn_{12}$ cluster from each other. The $Mn_{12}$-stearate compound prepared is soluble in most organic solvents and resistant against water catalyzed reduction. The $Mn_{12}$-stearate compound shows similar electrochemical, magnetic properties to the pristine $Mn_{12}$-acetate.

Detecting of Periodic Fasciculations of Avian Muscles Using Magnetic and Other Multimedia Devices

  • Nakajima, Isao;Tanaka, Sachie;Mitsuhashi, Kokuryo;Hata, Jun-ichi;Nakajima, Tomo
    • Journal of Multimedia Information System
    • /
    • 제6권4호
    • /
    • pp.293-302
    • /
    • 2019
  • In the past, there was a theory that influenza wasn't transmitted directly from birds but was infected to humans via swains. Recently, molecular level research has progressed, and it was confirmed that the avian influenza virus can directly infected to human lung and intestinal epithelial cells. Three pandemicsin the past 100 years were also infected to humans directly from birds. In view of such scientific background, we are developing a method for screening sick birds by monitoring the physiological characteristics of birds in a contactless manner with sensors. Here, the movement of respiratory muscles and abdominal muscles under autonomic innervation was monitored using a magnet and Hall sensor sewn on the thoracic wall, and other multimedia devices. This paper presents and discusses the results of experiments involving continuous periodic noise discovered during flight experiments with a data logger mounted on a Japanese pheasant from 2012 to 2015. A brief summary is given as the below: 1. Magnet and Hall sensor sewn to the left and right chest walls, bipolar electrocardiograms between the thoracic walls, posterior thoracic air sac pressure, angular velocity sensors sewn on the back and hips, and optical reflection of LEDs (blue and green) from the skin of the hips allow observation of periodic vibrations(fasciculations) in the waves. No such analysis has been reported before. 2. These fasciculations are presumed to be derived from muscle to maintain and control air sac pressure. 3. Since each muscle fiber is spatially Gaussian distributed from the sympathetic nerve, the envelope is assumed to plot a Gaussian curve. 4. Since avian trunk muscles contract periodically at all time, we assume that the sympathetic nerve dominates in their control. 5. The technique of sewing a magnet to the thoracic wall and measuring the strength of the magnetic field with a Hall sensor can be applied to screen for early stage of avian influenza, with a sensor attached to the chicken enclosure.

Alignment System Development for producing OLED using Fourth-Generation Substrate

  • Park, Jae-Yong;Han, Seok-Yoon;Lee, Nam-Hoon;Choi, Jeong-Og;Shin, Ho-Seon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.873-878
    • /
    • 2008
  • Doosan Mecatec has developed alignment system for Organic Light-Emitting Diode (OLED) display production using large size substrate. In the present article, The alignment system between the substrate and the mask, which is a core technology for producing the OLED product using the fourth-generation substrate with $730{\times}920mm^2$ or more, will be described by dividing into a substrate loader, a magnet unit, a CCD camera, etc. The substrate loader is optimized through the simulation where the central portion of the substrate droops by about 1.5mm by clamping each of a long side (920mm direction) and a short side (730mm direction) thereof by 6 point and 4 point. A magnet unit using a sheet type of rubber magnet is constituted and a CCD camera model with the specifications capable of minimizing the errors between a clear image and the same image is selected. The system to which an upward evaporation technique of small molecular organic materials will be applied has been developed so that repeatability and position accuracy becomes ${\pm}1{\mu}m$ or less using an UVW type of stage. Also, the vision accuracy of the CCD camera becomes ${\pm}1{\mu}m$ or less and the align process TACT becomes 30sec. or less so that the final alignment accuracy between the substrate and the mask becomes ${\pm}3{\mu}m$ or less. In order to meet an extra-large glass substrate, an evaporation system using an extra-large AMOLED substrate has been developing through a vertical type of an alignment system.

  • PDF

NMR 분광법의 원리와 지구환경과학에의 응용 (Theory of NMR Spectoscopy and Its Application in Geoenvironmental Sciences)

  • 김영규
    • 암석학회지
    • /
    • 제10권3호
    • /
    • pp.233-245
    • /
    • 2001
  • NMR분광법은 현재 화학에서 빼 놓을 수 없는 아주 중요한 연구방법의 하나지만 또한 지질학의 연구에 있어서도 초전도 자석의 발달과 함께 그 중요성이 부각되고 있다. 지질학에 있어서 NMR의 연구 대상 원소로는 광물의 주 구성 성분이며 여러 가지 구조적 정보를 갖고 있는 $^{29}Si$, $^{27}Al$ 등이 유용하게 사용되며 이들은 각각 다른 여러 정보들을 제공한다. 이 밖에도 $^{23}Na$와 같은 알칼리금속과 더불어 다양한 핵종들이 지질학에서 NMR로 연구되고 있다. NMR을 이용하여 다양한 방면의 연구들이 가능한데 NMR은 XRD, TEM보다도 더욱 작은 미시적인 (분자적 관점에서의) 구조 연구에 사용될 수 있다. 이러한 연구를 통해 Al, Si 질서-무질서, 산소원자와의 배위수, 인근의 다른 양이온의 분포 등을 포함한 구조적 정보를 알 수 있다. 또한 NMR의 또 다른 장점은 정적인 미시 구조뿐만 아니라 분자들의 움직임(dynamics)에 대한 정보도 알 수 있다는 것이다. 이러한 동적인 정보는 기존의 어느 방법으로도 알기 어려웠던 부분이고 NMR을 통하여 분자들의 상호 교환 속도와 활성화 에너지 등에 대한 폭 넓은 이해가 가능할 수 있다. 이 밖에 NMR을 이용하여 비정질 물질에 대한 구조와 더불어 지표면에서 산출되는 유기물에 대한 성분 및 구조도 아주 중요하게 연구될 수 있는 분야이다.

  • PDF

Small-Angle X-ray Scattering Station 4C2 BL of Pohang Accelerator Laboratory for Advance in Korean Polymer Science

  • Yoon, Jin-Hwan;Kim, Kwang-Woo;Kim, Je-Han;Heo, Kyu-Young;Jin, Kyeong-Sik;Jin, Sang-Woo;Shin, Tae-Joo;Lee, Byeong-Du;Rho, Ye-Cheol;Ahn, Byung-Cheol;Ree, Moon-Hor
    • Macromolecular Research
    • /
    • 제16권7호
    • /
    • pp.575-585
    • /
    • 2008
  • There are two beamlines (BLs), 4C1 and 4C2, at the Pohang Accelerator Laboratory that are dedicated to small angle X-ray scattering (SAXS). The 4C1 BL was constructed in early 2000 and is open to public users, including both domestic and foreign researchers. In 2003, construction of the second SAXS BL, 4C2, was complete and commissioning and user support were started. The 4C2 BL uses the same bending magnet as its light source as the 4C1 BL. The 4C1 BL uses a synthetic double multilayer monochromator, whereas the 4C2 BL uses a Si(111) double crystal monochromator for both small angle and wide angle X-ray scattering. In the 4C2 BL, the collimating mirror is positioned behind the monochromator in order to enhance the beam flux and energy resolution. A toroidal focusing mirror is positioned in front of the monochromator to increase the beam flux and eliminate higher harmonics. The 4C2 BL also contains a digital cooled charge coupled detector, which has a wide dynamic range and good sensitivity to weak scattering, thereby making it suitable for a range of SAXS and wide angle X-ray scattering experiments. The general performance of the 4C2 BL was initially tested using standard samples and further confirmed by the experience of users during three years of operation. In addition, several grazing incidence X-ray scattering measurements were carried out at the 4C2 BL.