• Title/Summary/Keyword: molar

Search Result 4,039, Processing Time 0.03 seconds

Three-dimensional finite element analysis for the effect of retentive groove design on joint strength of casting connection (유지구 설계가 주조연결강도에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Kim, Jung-Woo;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.29-38
    • /
    • 2009
  • Statement of problem: A casting connection technique is widely used for repair, correction and addition to base metal framework. However, a casting connection technique may increase the risk of failure in clinical situations when high stresses exist. Purpose: The purpose of this study was to investigate the mechanical retentive groove design comparatively to increase the joint strength by using the three-dimensional finite element analysis model of a 3-unit fixed partial denture. Material and methods: Ten finite element models were constructed. (Model A: One retentive groove, Model B: Two retentive grooves, Model C: Three retentive grooves, Model D: Four retentive grooves, Model E: One horizontal groove and two vertical grooves, Model F: Two horizontal grooves and one vertical groove, Model G: One groove with the enlarged dimension, Model H: Two grooves with the enlarged dimension, Model I: One groove with the increased height, Model J: One groove with the increased width of base). The vertical force was applied to the mesial and the distal fossa to the casting connection of mandibular first molar. Results: The main factors, affecting joint strength of casting connection were both the retention between the primary cast and the secondary cast and the thickness of the primary cast remaining after preparing retentive groove. The increase of retentive force, according to the numbers and the dimension of retentive groove had an effect on distributing stress. However, in some cases, the increase of retentive force resulted in the increase of stress by reducing thickness of the primary cast in the connection area. Conclusion: The design of retentive groove that limits number of retentive groove for metal thickness and increases the depth of retentive groove for retention is highly recommended.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Analysis of occlusal contact and guidance pattern during maximal intercuspal position and protrusive movement (최대교두감합위 및 하악 전방운동 시의 교합접촉 및 교합유도 양상에 관한 분석)

  • Kim, Jiyeon;Kim, Kang-Hyun;Noh, Kwantae;Kim, Hyeong-Seob;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • Purpose: The importance of occlusal contacts of the natural dentition for durability of teeth, mandibular stabilization, and restorative dentistry is well known. The purpose of this study is to analyze the occlusal contact and guidance pattern of Koreans by evaluating the static occlusion on maximal intercuspal position and measuring dynamic occlusion during straight protrusion. Materials and methods: The occlusal contacts at maximal interincisal position and the occlusal guidance pattern during straight protrusion of 29 subjects were recorded with shimstock foil (Whaledent, Langenau, Germany), T-Scan III (Tekscan Inc., Boston, MA, USA), polyvinylsiloxane registration material (Genie Bite, Sultan Healthcare, Hackensack, NJ, USA) and compared. Occlusal registration procedures were repeated 3 times. The position was fixed to an upright position and the head position was fixed with the Frankfurt horizontal plane paralleling the horizontal plane. Fisher's Exact Test (R-General Public License, ver. 2.14.1) and Pearson's Test were used to assess the significance level of the differences between the experimental groups (${\alpha}=.05$). Results: When using shimstock foil, T-Scan III system, and polyvinylsiloxane registration material, most of the patients showed contact on anterior, premolar, and molar teeth during maximal intercuspal position. Approximately 51% of maximal intercuspal position showed anterior contact using shimstock foil. When examining the protrusive movement using shimstock foil and T-Scan III system, guidance pattern with the central incisor was the most common. Conclusion: During maximal intercuspal position, there were cases in which not all of the teeth showed occlusal contact. During mandibular protrusive movements, one or more maxillary central incisors frequently joined in straight protrusion and the posterior teeth were disoccluded. Therefore, the anterior teeth protect the posterior teeth, and vice versa. Thus, mutually protected occlusion should be applied when reconstructing occlusion.

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.

COMPARISON OF MICROLEAKAGE IN SEALANT REPAIRED WITH DIFFERENT SURFACE TREATMENT (파손된 치면열구전색제의 수리 방법에 따른 미세누출 비교)

  • Kang, Myung-Bong;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taek;Lee, Sang-Hoon;Hahn, Se-Hyun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.204-214
    • /
    • 2007
  • The aim of this study was to investigate whether differences in surface treatment prior to repair influenced the seal of a resin fissure sealant placed on the occlusal surfaces of permanent molar teeth. One hundred and twenty extracted human molars were selected and a light curing sealant was placed on their occlusal surface following cleaning by prophylaxis and acid etching. The teeth were deliberately damaged, and then stored in artificial saliva for four weeks. Sixty teeth with the desired morphology of sealant failure were randomly divided into four groups where one group was treated with only etching agent, another by only air-abrasion, another by applying an etching agent followed by a bonding agent, and the last by air-abrasion followed by a bonding agent each. After sealant application, the samples were thermocycled and the degree of microleakage was determined. The results were as follows : 1. In the sealant/sealant interface group 2(0.22), 4(0.23) using air-abrasion showed a significantly lower microleakage score than group 1(0.38), 3(0.35) using an etching agent(p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 2 and groups 3, 4. 2. In the sealant/tooth interface, group 3(0.20), 4(0.20) which used a bonding agent showed a significantly lower microleakage score than group 1(0.35), 2(0.40) (p<0.05). There were no statistically significant differences(p>0.05) between groups 1, 3 and groups 2, 4. 3. In SEM examination, while sealant surfaces treated with etching did not result in highly rough surfaces, those treated with air-abrasion did show rough surfaces.

  • PDF

COMPARATIVE STUDY OF PHYSICAL PROPERTIES FOR VARIOUS BAND CEMENTS (수종의 밴드 접착 시멘트의 물성에 대한 비교 연구)

  • Yang, Kyu-Ho;Kim, Ki-Baek;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.427-432
    • /
    • 2009
  • The aim of this study was to compare the shear-peel strength and the fracture site of 5 commercially available orthodontic band cements. One hundred molar bands were cemented to extracted human 3rd molars. The specimens were prepared in accordance with the manufacturer's instructions for each cement. After storage in a humidor at $37^{\circ}C$ for 24 hours, the shear debonding force was assessed for each specimen using an universal testing machine with crosshead speed of 2 mm/minute. Maximal failure stress was converted to mean shear-peel strength, MPa. The predominant site of band failure was recorded visually for all specimens as either at the band/cement or cement/enamel interface. Mean shear-peel strength of Ormco was the highest(2.44${\pm}$0.57), followed by Fuji $Ortho^{TM}$(2.24${\pm}$0.50), $Ketac-Cem^{TM}$(2.10${\pm}$0.57), 3M $Unitek^{TM}$(1.82${\pm}$0.43), $Band-Lok^{TM}$(1.73${\pm}$0.28). There were statistically significant differences between Ormco and $Band-Lok^{TM}$, Ormco and 3M $Unitek^{TM}$, and Fuji $Ortho^{TM}$ and $Band-Lok^{TM}$(p<0.05). The predominant site of bonding failure for bands cemented with the Ormco was at the band/cement interface, whereas bands cemented with Ultra $Band-Lok^{TM}$ failed predominantly at the enamel/cement interface. There was no significant difference among the other cements(Fuji $Ortho^{TM}$, 3M $Unitek^{TM}$, $Ketac-Cem^{TM}$).

  • PDF

Effect of N-Acetylcysteine on the Supetoxide Release, Chemotaxis from the Neutrophils and Glutathione Level of Plasma and Neutrophils (N-Acetylcysteine이 호중구의 Superoxide, Chemotaxis 및 혈장과 호중구의 Glutathione에 미치는 영향)

  • Song, Jeong-Sup;Lee, Sook-Young;Moon, Hwa-Sik;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.475-483
    • /
    • 1994
  • Background: N-acetylcysteine(ACE) is used both orally and intravenously in a variety of experimental pathologies resembling human disease states which exhibit endothelial toxicity as a result of oxidative stress, including acute pulmonary oxygen toxicity, septicemia and endotoxin shock. Despite these observations in vivo, it is not certain how this thiol drug produces its protective effects. ACE is a cysteine derivative which is able to direct1y react with oxygen radicals and may also act as a cysteine and glutathione(GSH) precursor following deacetylation. In this paper, we tried to know whether the therapeutic doses of ACE can modify the inflammatory function of the neutrophils and can increase the glutathione level of plasma in chronic obstructive pulmonary disease(COPD) patients. In addition, the effect of ACE to the purified neutrophil in terms of superoxide release and glutathione synthesis were observed. Method: Firstly, we gave 600mg of ACE for seven days and compare the release of superoxide, luminol-enhanced chemiluminescence from the neutrophils, neutrophil chemotaxis, and plasma GSH levels before and after ACE treatment in COPD patients. Secondly, we observed the dose dependent effect of ACE to the purified neutrophil's superoxide release and GSH levels in vitro. Results: 1) Usual oral therapeutic doses(600mg per day) of ACE for seven days did affect neither on the neutrophil's superoxide release, chemiluminescence, chemotaxis, nor on the plasma GSH concentration in the COPD patients. 2) ACE decreases the purified neutrophil's superoxide release and increase the GSH production in dose dependent fashion in vitro. Conclusion: Despite the fact that oral ACE treatment did not affect on the neutrophil's inflammatory function and plasma GSH concentration in COPD patients in usual therapeutic doses, it decreases the superoxide release and increases the GSH production from the isolated neutrophils in high molar concentrations. These findings suggest that to obtain an antioxidative effects of ACE, it might be needed to increase the daily dosage of ACE or therapeutic duration or change the route of adminisration in COPD patients.

  • PDF

Environmental Impact Assessment by Marine Cage Fish Farms: II. Estimation of Hydrogen Sulfide Oxidation Rate at $O_2$-H$_2$S Interface and Sulfate Reduction Rate in Anoxic Sediment Layer (해상 어류가두리양식장의 환경영향 평가: II. 가두리 양식장 퇴적물의 산소-황화수소 경계면에서 황화수소의 산화율 및 무산소 퇴적층에서 황산염 환원율 추정)

  • Lee, Jae-Seong;Kim, Kee-Hyun;Yu, Jun;Lee, Pil-Yong;Jung, Rae-Hong;Lee, Wong-Chan;Han, Jung-Jee;Lee, Yong-Hwa
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.2
    • /
    • pp.64-72
    • /
    • 2004
  • We measured the vertical profiles of $O_2$, H$_2$S, and pH in sediment pore water beneath marine cage fish farms using a microsensor with a 25 ${\mu}{\textrm}{m}$ sensor tip size. The sediments are characterized by high organic material load. The oxygen consumption, hydrogen sulfide oxidation, and sulfate reduction rates in the microzonations (derived from the vertical distribution of chemical species concentration) were estimated by adapting a simple one-dimensional diffusion-reaction model. The oxygen penetration depth was 0.75 mm. The oxic microzonations were divided into upper and lower layers. Due to hydrogen sulfide oxidation within the oxic zone, the oxygen consumption rate was higher in the lower layer. The total oxygen consumption rate integrated with reaction zone depth was estimated to be 0.092 $\mu$mol $O_2$cm$^{-2}$ hr$^{-1}$ . The total hydrogen sulfide oxidation rate occurring within 0.7 mm thickness was estimated to be 0.030 $\mu$mo1 H$_2$S cm$^{-2}$ hr$^{-1}$ , and its turnover time in the oxic sediment layer was estimated to be about 2 minutes. This suggests that hydrogen sulfide was oxidized by both chemical and microbial processes in this zone. The molar consumption ratio, calculated to be 0.84, indicates that either other electron accepters exit on hydrogen sulfide oxidation, or elemental sulfur precipitation occurs near the $O_2$- H$_2$S interface. Total sulfate reduction flux was estimated to be 0.029 $\mu$mol cm$^{-2}$ hr$^{-1}$ , which accounted for more than 60% of total $O_2$ consumption flux. This result implied that the degradation of organic matter in the anoxic layer was larger than in the oxic layer.

Effect of Steviol β-Glucopyranosyl Ester on The Production of Nitric Oxide and Inflammatory Cytokines in RAW 264.7 Cells (Steviol β-Glucopyranosyl Ester가 RAW 264.7 세포의 산화질소 및 염증성 사이토카인 생성에 미치는 영향)

  • Jung, Heehoon;Cho, Uk Min;Hwang, Hyung Seo;Cho, Kun;Lee, Sang Rin;Kim, Moo Sung
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.3
    • /
    • pp.239-247
    • /
    • 2018
  • Chronic inflammation is known to have effects on various diseases such as gout, cancer, dementia, atopic disease, and obesity. In addition, since some signal cascades involved in the development of inflammation are known to affect the damage and aging of the skin tissue, studies are being conducted actively to control the inflammation mechanism. In order to mitigate or prevent inflammatory response, a number of researches have been made to develop anti-inflammatory materials from some plants. In particular, Stevia rebaudiana produces steviol glycosides (SG), a natural sweetener with a distinctive flavor. Studies on some of SG have been shown to have anti-inflammatory activity. Researchers of this study expected that more SG also possess anti-inflammatory activity, besides stevioside, rebaudioside A, and steviol. In order to confirm this possibility, the researchers screened inhibition activity of various steviol glucosides for NO production in RAW 264.7 cell lines. As a result, steviol ${\beta}-glucopyranosyl$ ester (SGE) showed the highest inhibitory activity among steviol derivatives treated at the same molar concentration. In addition, we found that mRNA expression level of $interleukin-1{\alpha}$ ($IL-1{\alpha}$), $interleukin-1{\beta}$ ($IL-1{\beta}$), cyclooxygenase-2 (COX-2), nuclear factor kappa-light chain-enhancer of activated B cells ($NF-{\kappa}B$) and inducible nitric oxide synthase (iNOS) was also decreased in a dose-dependent manner. These results show that SGE inhibits anti-inflammatory activity and NO production in mouse macrophage RAW 264.7 cells. It was confirmed that SGE has potential to be applied as an anti-inflammatory material.

Petrological Study of the Dioritic and Granitic Rocks from Geochang Area (거창 일대에 분포하는 섬록암류와 화강암류에 대한 암석학적 연구)

  • Han, Mi;Kim, Sun-Woong;Yang, Kyoung-Hee;Kim, Jin-Seop
    • The Journal of the Petrological Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.167-180
    • /
    • 2010
  • The geochemical studies on the plutonic rocks of the Geochang, the central part of the Ryongnam massif, were carried out in order to constrain the petrogenesis and the paleotectonic environment. The objects of this study are dioritic rocks, biotite granite and hornblende granite. The modal compositions indicate that the dioritic rocks are quartz diorite, quartz monzodiorite, tonalite, biotite granites are granodiorite, granite and hornblende granites are granite, quartz monzonite, quartz syenite. These rocks belong to the calc-alkaline series. Especially, trace elements such as Sr, Nb, Sr, Ti are depleted, suggesting that these rocks are produced in the subduction zone related to calc-alkaline series. Also, the studied granitic rocks correspond to peraluminous and I-type. Chondrite-normalized REE patterns show that LREE are enriched much more than HREE, and have weak Eu(-) anomaly. It is similar to pattern of Jurassic granitoids in the South Korea. Total REE value of the biotite granite and hornblende granite ranges 76.21~137.05 ppm and 73.84~483.21 ppm, respectively, also $(La/Lu)_{CN}$ value ranges 9.61~36.47 and 7.17~21.85. It is suggest that studied rocks suppor their emplacement at active continental margin. Also, these rocks are derived from magma generated by partial melting of lower continental crust materials.