• Title/Summary/Keyword: moisture maximizing rate

Search Result 3, Processing Time 0.02 seconds

Estimation of the Moisture Maximizing Rate based on the Moisture Inflow Direction : A Case Study of Typhoon Rusa in Gangneung Region (수분유입방향을 고려한 강릉지역 태풍 루사의 수분최대화비 산정)

  • Kim, Moon-Hyun;Jung, Il-Won;Im, Eun-Soon;Kwon, Won-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.9
    • /
    • pp.697-707
    • /
    • 2007
  • In this study, we estimated the PMP(Probable Maximum Precipitation) and its transition in case of the typhoon Rusa which happened the biggest damage of all typhoons in the Korea. Specially, we analysed the moisture maximizing rate under the consideration of meteorological condition based on the orographic property when it hits in Gangneung region. The PMP is calculated by the rate of the maximum persisting 12 hours 1000 hPa dew points and representative persisting 12 hours 1000 hPa dew point. The former is influenced by the moisture inflow regions. These regions are determined by the surface wind direction, 850 hPa moisture flux and streamline, which are the critically different aspects compared to that of previous study. The latter is calculated using statistics program (FARD2002) provided by NIDP(National Institute for Disaster Prevention). In this program, the dew point is calculated by reappearance period 50-year frequency analysis from 5% of the level of significant when probability distribution type is applied extreme type I (Gumbel distribution) and parameter estimation method is used the Moment method. So this study indicated for small basin$(3.76km^2)$ the difference the PMP through new method and through existing result of established storm transposition and DAD(Depth-Area-Duration). Consequently, the moisture maximizing rate is calculated in the moisture inflow regions determined by meteorological fields is higher $0.20{\sim}0.40$ range than that of previous study. And the precipitation is increased $16{\sim}31%$ when this rate is applied for calculation.

A Study on the Performance of Home Clothes Dryer using Thermoelectric Module (열전소자를 이용한 가정용 의류 건조기의 성능에 관한 실험적 연구)

  • Lee, Min-Jae;Gong, Sang-Un;Kim, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2073-2078
    • /
    • 2007
  • This study was performed to develop a dryer for home clothes using thermoelectric module. The thermoelectric module was used as a heat source and a dehumidification device because it has heating part and cooling part at once. To design for maximizing the energy efficiency and the rate of dehumidification, the parameters of the dryer using thermoelectric module are heat capacity and air flow rate. This study showed that the thermoelectric module can be used in the clothes dryer and energy efficiency of clothes dryer be better than that of electric heating dryer.

  • PDF

Estimation of moisture maximizing rate considering an orographic property : Typhoon Rusa case in Gangneung region (지형적 특성을 고려한 강릉지역 태풍 루사의 수분최대화비 산정)

  • Kim, Moon-Hyun;Lee, Hye-Ran;Im, Eun-Soon;Kwon, Won-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1483-1487
    • /
    • 2006
  • 본 연구에서는 2002년 태풍 루사(RUSA) 기간에 대한 강릉지역의 수분최대화비를 그 지역의 지형적인 특성을 고려하여 산정하였다. 수분최대화비는 최대가능강수(Probable Maximum Precipitation, 이하 PMP)를 추정하는데 가장 중요한 요소로써 최대 12시간 지속 1000 hPa 이슬점과 대표 12시간 지속 1000 hPa 이슬점에 따른 가강수량의 비로 계산된다. 각각의 이슬점을 결정하는 방법으로, 대표 12시간 지속 이슬점은 수분 유입지역을 파악함으로써 계산되는데, 이 유입지역은 지상일기도, 지표 풍향, 850 hPa 수분속, 유선장등을 고려하여 선정되었다. 또한 최대 12시간 지속 이슬점은 과거 42년간(1961년${\sim}$2002년)의 강릉지역 이슬점 온도 자료를 통해 방재연구소에서 제공하는 FARD2002 통계프로그램을 이용하여 구하였다. 이 프로그램에서 확률분포형으로는 Extreme TypeⅠ(Gumbel distribution)을 선정하였고 매개변수 추정방법으로 모멘트법을 사용하여 유의수준 10%에서 재현기간 50년 빈도 분석을 통해 이슬점 온도를 구하였다. 본 연구에서는 이와 같은 과정을 통해 재 추정된 수분최대화비와 기존에 제시된 호우전이비 및 DAD(Depth-Area-Duration) 분석결과를 이용하여 강릉호우의 소유역$(3.76km^2)$에 대한 PMP를 산정하고 기존 결과와의 차이점을 제시하였다.

  • PDF