• 제목/요약/키워드: moisture content of paddy

검색결과 117건 처리시간 0.027초

금호지구 저습답의 암거배수효과에 관한 연구(I) (Studies on Wet Paddy Field Underdrainage Improvement in the Gum-Ho Area (I))

  • 김조웅;김시원
    • 한국농공학회지
    • /
    • 제22권4호
    • /
    • pp.82-95
    • /
    • 1980
  • This paper complies the results of the studies so far made on the subsoil improvement of subsurface drainage systems for wet paddy fields (those were located in the Gum-Ho area in Kyung Buk province) which had poor permeability and a high water table. In general, a drainage problem is an excess of water on the ground surface which can effect the productivity and bearing capacity of the soil. With drain pipe systems, (According to their depths and spacing) it may be possible to correct that problem. The experimentation consisted of three test plots, two of which included drain pipe systems with varing depths and width spacing of the pipes. The third plot (C) was an ordinary plot being exempt of a drain pipe system. In detail, the depth of plot A was 80 cm, and the width spacings began at 2. Om and increased by 2. Om up to 10. 0m. The depth of plot B was 60cm and the width spacing was the same as plot A. These tests were performed to research specific details; such as crop yeild, bearing capacity of the soil, the amount of underdrainage, surface cracks, root distribution, the water table level, the consumptive water depth and the soil moisture content. The test period lasted three years, from 1977 thru 1979. The results obtained were as follows: 1. During the test period, the weather conditions for the area tested were in accordance with the annual average for that area. Furthermore the precipitation factor during the spring cultivation season, the intermediate drainage period and the harvest drainage period was of optimum conditions for controling surface cracks, because of less precipitation than evaporation. 2. The difference in the level of the ground water table in plots A and B was hardly noticable, but the difference in the test plots and the ord. plot was greatly noticable. The test plots (A, B) were 30 to 40cm lower than the ordinary plot. On the whole, the ground water table of the ord. plot always stayed at a level of 15-20cm beneath the surface of the soil, the ground water table of the test plot A showed The difference in the depth of the pipe lower than the test plot B, while the test plots showed a remarkable descending effect. 3. The soil temperature in plot A was slightly core than in plot B with a difference of 0. 47$^{\circ}$C, but plot A was 1. 6$^{\circ}$C higher than the ord. plot during the flooding period, but after drainage the temperature difference climed to 2. 0$^{\circ}$C. 4. During the 3rd test year, the values of the cracks were recorded with the values of 59cm in plot A, 42cm in plot B and 15cm in the ordinary plot. Plots A and B had increased 2.5 times the value of the first year while the ordinary plot had remained the same. 5. The root weight of the rice was measured at a value of 77.2 gr. for plot A, 73.5 gr. for plot B and 65.3 gr. for the ord. plot. Therefore, the root growths in plots A and B were much more energetic than in the ord. plot. 6. The consumptive water depth measured during the 3rd year resulted in the values of 26. 0mm per day for plot A, and 24.9 mm per day for plot B, respectively. Therefore, both plot A and plot B maintained the optimum consumptive water depths, but the ordinary plot only obtained the value of 12.3 mm per day, which clearly showed less than the optimum consumptive water depth which is 20 to 30 mm/day. 7. The soil moisture content is in direct relationship to the ground water level. During drainage, test plot A decreased in its ground water level much more rapidly than the other two plots. Therefore, plot A had a much less soil moisture content. But this decreased water level could be directly effected by the weather conditions. 8. The relationship between the bearing capacity and the soil moisture content were directly inversely proportional. It can be assumed that the occurence of soil creaks is limited by the soil moisture content. Therefore, the greater the progress of the surface creaks resulted in a greater bearing capacity. So, tast plot A with a greater amount of surface cracks than the other test plots resulted in a greater bearing capacity. But, the bearing capacity at the harvest season could be effected by the drainage during the intermediate drainage period and by the weather conditions. 9. Comparing the production of the test plots to the ord. plot; there was an increased value of 840kg for plot A, 755kg for plot B and 695kg for the ord. plot in the rough rice. Therefore, plot A had an increase of 20% over the ordinary plot. The possibility of producing double crops was investigated. The effects on barley production in the test plots showed a value of 367kg per 10 acres, which substantiated the possibility of double crops because that value showed an increased value over the average yearly yield for those uplands. 10. So as a result, it can be recommended that by including a drain pipe system with the optimum conditions of an (80cm centimeter) depth and a (l0m) spacing will have a definite positive effect on the over all production capacity and quality of wetpaddy fields.

  • PDF

곡물냉각기를 이용한 철제 원형빈에서 벼 냉각 (Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler)

  • 김의웅;김동철
    • 한국식품저장유통학회지
    • /
    • 제11권2호
    • /
    • pp.263-268
    • /
    • 2004
  • 곡물냉각기를 이용하여 벼의 냉각특성을 구명하기 위하여 RPC의 원형빈에서 2회의 냉각실험을 실시하였다. 1차 냉각 실험은 하절기에 200 톤 규모의 원형빈에서, 2차 냉각실험은 수확기에 300 톤 규모의 원형빈에 저장된 벼를 대상으로 실시하였다. 그 결과를 요약하면 다음과 같다. 1차 냉각실험에서 초기곡온 23.6$^{\circ}C$, 함수율 19.3%인 벼180.3 톤을 14$^{\circ}C$까지 냉각시키는데 52.5시간이 소요되었으며, 냉각을 통해 함수율은 약 0.6% 감소하였다. 또한, 2차 냉각실험에서 초기곡온 16.1$^{\circ}C$, 함수율 19.2%인 벼 272.2 톤을 5.5$^{\circ}C$까지 냉각시키는데 78.0시간이 소요되었다. 1, 2차 냉각실험에서 냉각공기온도를 각각 8.0, 5.5$^{\circ}C$로 설정하였을 때, 곡물냉각기출구의 냉각공기온도는 각각 8.0$\pm$0.48$^{\circ}C$, 5.7$\pm$0.84$^{\circ}C$로서 정밀하게 제어되고 있음을 알 수 있었으며, 2차 냉각실험에서의 온도편차가 1차 냉각실험에서보다 높게 나타난 것은 냉각부하가 적었고, 외기조건이 급격하기 변화하여 압축기 무부하전자변, 재열기 및 증발기에 공급되는 고온고압 냉매가스량, 응축기 송풍기가 제어되었기 때문으로 판단되었다. 1차 냉각실험에서 곡물냉각기에서 냉각된 공기량은 평균77.5㎥/min인데 비해 곡물층을 통과한 냉각공기량은 42.5㎥/min에 불과해 약 45%의 냉각공기가 누설되어 이에 대한 방지책이 필요하였다. 냉각부하가 큰 하절기에 실시한 1차 냉각실험에서는 댐퍼만이 제어되었으며, 소요전력은 평균 22.1㎾를 나타낸 반면, 냉각부하가 적은 수확기에 실시한 2차 냉각실험에서는 압축기의 무부하전자변, 응축기 송풍기 등이 제어되었으며, 소요전력은 평균 17.4㎾로 나타나 하절기에 비하여 약 27%정도의 에너지가 절감된 것으로 나타났다.

벼의 수확작업 체계별 수확정기 결정에 관한 연구 (Study on the Optimum Harvest Timing for Different Operational Systems of Rice)

  • 이종호;강화석;정창주
    • Journal of Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.88-99
    • /
    • 1978
  • In this study, rice harvesting systems suitable to Korean situations and the optimum timing of these systems were determined, respectively, based on experimentally determined factors such as filed yield and the milling quantity and quality measured at various levels of the grain moisture content at harvest. Rice varieties used for the experiment were the AKIBARE (Japonica-type) and the SUWEON 251 (high yielding TONGIL sister-line variety), The harvesting systems studied by the experimental work of this study were traditional system with both the wet material and dry-material threshing system by use of binder with both the dry-material and wet-material threshings, and system by use of combine. Grain samples were taken from final products of the paddy rice harvested from the experiment a fields for each system to measure the recovery rates of the milled rice. The results may be summarized as follows; 1. The milling recovery rate of the AKIBARE variety had highest value within the range of the grain moisture at harvest, showing from 21 to 26 percent. The head-rice recovery for the same variety was a little greater in the wet-material threshing than in the dry-material threshing , higher values of which , were 20 to 25 percent , seen within the range of grain moisture at harvest regardless of the harvesting systems tested. 2. The milling recovery of the SUWEON 251 , when tested for different harvesting systems and harvesting grain moisture, did not show a statistically significant different. In contrast , head-rice recovery for the systems operated by the wet-material threshing was much greater than that by the -material threshing. The difference of the recoveries between these systems range from 2.6 to 4.7 percent. 3. An assessment of the optimum period of -harvest timing for each of the harve\ulcornersting systems tested were made bJ.sed on (a) the maximum total milled-rise yield and (b) the percentage reduction in the total milled-rice yield due to untimely harvest operations. The optimum period determined are: 23-19% for the ATD, AC, STD, SBW, STW systems, 25-21% for the ATW ani ABW systems, and 27-18% for the ABD, SBD, and SC systems, respectively.

  • PDF

답리작 맥류 랩-사일리지의 기계화 시스템 모델 개발(4) - 답리작 맥류 랩-사일리지의 저장특성 및 품질평가 - (Development of Mechanized System Model for the Production of Winter Cereal Wrap Silage in the Fallow Paddy Field(4) - Storage property and quality analysis of winter cereal wrap silage -)

  • 김혁주;박경규;하유신;홍동혁
    • Journal of Biosystems Engineering
    • /
    • 제29권4호
    • /
    • pp.293-300
    • /
    • 2004
  • In order to solve the shortage of roughage supply for dairy farm in Korea, the mechanized model system for the production of winter cereal wrap silage in the fellow paddy field was developed in the previous studies. In this study, storage properties after long term storing of the winter cereal wrap silage were investigated. Also, the qualities of the wrap silage which was stored during 4 months were evaluated by sensory testings, analyzing chemical properties(moisture content, pH and organic acids) and investigating the increase of feeding value. The result of this study were summarized as follows; 1. After 300 hours storage, the acid level of the silage decreased slowly to 4.6 -4.8 pH. Also, the temperature was stabilized around 27-28$^{\circ}C$. The silage having below 5.0 pH is a desirable level for the most of good silage. 2. According to the sensory test and chemical property analyzation it was evaluated as the first class silage like a com silage. 3. Also, when the wrap silage are fed to the cattle, the cattle produced milk more 25% than that of conventional feed. 4. As an overall conclusion, winter cereal wrap silage in the fallow paddy field cm be one of the major roughage source in replacement of com and other conventional silage to dairy cattle in Korea.

논과 밭 토양의 황산염 환원세균 군집 구조 비교 (Comparison of community structure of sulfate reducing bacteria in rice paddy and dry farming soils)

  • 이중배;박경량
    • 미생물학회지
    • /
    • 제51권1호
    • /
    • pp.21-30
    • /
    • 2015
  • 본 연구는 논과 밭 토양의 황산염 환원세균의 군집구조와 T-RFLP 패턴을 조사한 논문으로, 유기 농법 토양과 관행 농법 토양 그리고 밭 토양 총 3종류의 토양을 8월과 11월에 채집하여 실험하였다. 토양 성분 분석 결과 총 질소, 총 탄소, 총 인의 값은 모든 토양이 비슷하게 나타났고 계절별로는 수분의 함량은 8월에, 총 탄소는 11월에 가장 높게 나타났다. 황산염 환원세균은 초산보다 젖산을 기질로 이용하는 황산염 환원세균이 더 많이 분포하고, 유기 농법 토양에 황산염 환원세균이 가장 많이 분포하는 것으로 나타났다. 각 토양에서 얻은 총 181개 클론으로 계통학적 분석을 한 결과, 대부분의 클론들은 배양 가능한 황산염 환원세균과는 매우 낮은 상동성을 보였으나, 자연계에서 확인되는 클론들과는 90% 이상의 높은 상동성을 나타내었다. T-RFLP 분석 결과 91, 357, 395, 474 bp의 분포가 가장 높았고, 계절에 따라 황산염 환원세균의 군집 구조가 달라지는 것을 확인하였다.

써레질 용수에 관한 포장실험 (Field experiment on the harrow-water requirement)

  • 김태철;안병기
    • 한국농공학회지
    • /
    • 제27권1호
    • /
    • pp.71-76
    • /
    • 1985
  • The objectives of this field experiment was to determine and recommend the water requirement for harrow considering the factors of soil class and soil moisture status. Experiment was conducted at the -paddy field of the Office of Rural Development in Chungnam Province. The results of experiment were summarized as follows: 1. Continuous drought day of 10-yr return period in transplanting season was about 25 days and the water content ratios at that point were approximately 20% in clayey-loam soil and 12% in sandy-loam soil irrelevantly to the soil-depth. 2. It was recommended that harrow-water requirement for standard design were approximately 9Omm in clayey-loam soil, 110mm in loamy soil and l3Omm in sandy-loam soil.

  • PDF

벼품종과 도정단계에 따른 열풍 팽화 특성 (Puffability with Hulling steps and Rice Varieties by Hot Air Puffer)

  • 김중만;김동한;백승화;최용배;한성희
    • Applied Biological Chemistry
    • /
    • 제37권2호
    • /
    • pp.72-76
    • /
    • 1994
  • 고미의 효율적 소비방법에 관한 연구의 일환으로 열풍식 팽화기($210{\pm}5^{\circ}C$, $55{\pm}5\;sec.$)를 이용하여 나락의 팽화 특성을 벼의 형태와 품종별로 비교하였다. 열풍에 의한 팽화효과는 나락이 현미나 백미에 비하여 월등하게 우수하였고 형태별 팽화된 전분의 상대적 결정화도 역시 나락이 백미나 현미보다 매우 낮았다. 팽화나락과 현미의 팽화체적 증가율은 찰벼가 메벼에 비하여 높았으며 팽화적성은 운봉올찰벼와 진주벼가 양호(P=0.05)하였다. 최대 팽화력을 나타내는 나락의 수분함량은 $10{\sim}12%$이었다.

  • PDF

미곡저장에 있어서 저장균류의 생육 및 억제에 관한 연구 (Studies on the Growth and Control of Storage Fungi in Stored Paddy Rice)

  • Mheen, T.I.;Cheigh, H.S.;Ragunathan, A.N.;Majumder, K.S.
    • 한국미생물·생명공학회지
    • /
    • 제10권4호
    • /
    • pp.297-305
    • /
    • 1982
  • 한국산 미곡 밀양 25호의 저장중에 출현한 균류의 생육환경조건을 조사하고, 이들 균류에 의한 미곡의 부패를 억제하기 위하여 선정된 훈연제의 최적처리조건을 검토하여 다음과 같은 결과를 얻었다. 1. 대부분의 균류는 수분함량 19%, 상대온도 80% 이상의 미곡에서는 10~30일 이내에 잘 생육하였다. 그러나 수분함량 12.5~l3.0 %의 미곡에서는 Aspergillus candidus, Asperillus versicolor, Penicillium chrysogenum 및 Trichothecium roseum만 2개월 이내에 육안으로 생육이 확인되었고, 기타의 균류는 현미경하에서 균계의 생육만 관찰 할 수 있었다. 2. 10종류의 공시훈엽제중에서 저장균류의 생육을 억제하는데 가장 효과가 있었던 것은 ethylene oxide였으며 그 최저처리농도 및 시간은 16mg/$\ell$와 48시간이었다. 동일처리시간에서 methylbromid는 32mg/$\ell$, acrilonitrile과 methyl iodide는 64mg/$\ell$가 최저처리농도였으며, ammonia, methyl formate, ethyl formate, carbon dioxide 및 propionic acid는 주어진 처리조건에서 거의 효과가 없었다.

  • PDF

토양 조건에 따른 농업용 트랙터의 견인 성능 분석 (Analysis of Traction Performance for Agricultural Tractor According to Soil Condition)

  • 이남규;김용주;백승민;문석표;박성운;최영수;최창현
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.133-140
    • /
    • 2020
  • Traction performance of a tractor varies depending on soil conditions. Sinkage and slip of the driving wheel for tractor frequently occur in a reclaimed land. The objective of this study was to develop a tractor suitable for a reclaimed land. Traction performance was evaluated according to soil conditions of reclaimed land and paddy field. Field experiments were conducted at two test sites (Fields A: paddy field; and Field B: reclaimed land). The tractor load measurement system was composed of an axle rotation speed sensor, a torque meter, a six-component load cell, GPS, and a DAQ (Data Acquisition System). Soil properties including soil texture, water content, cone index, and electrical conductivity (EC) were measured. Referring to previous researches, the tractor traveling speed was set to B3 (7.05 km/h), which was frequently used in ridge plow tillage. Soil moisture contents were 33.2% and 48.6% in fields A and B, respectively. Cone index was 2.1 times higher in field A than in field B. When working in the reclaimed land, slip ratios were about 10.5% and 33.1% for fields A and B, respectively. The engine load was used almost 100% of all tractors under the two field conditions. Traction powers were 31.9 kW and 24.2 kW for fields A and B, respectively. Tractive efficiencies were 83.3% and 54.4% for fields A and B, respectively. As soil moisture increased by 16.4%, the tractive efficiency was lowered by about 28.9%. Traction performance of tractor was significantly different according to soil conditions of fields A and B. Therefore, it is necessary to improve the traction performance of tractor for smooth operations in all soil conditions including a reclaimed land by reflecting data of this study.

경사지 배수불량 논에서 배수개선 효과의 지구통계적 기법을 이용한 평가 (Evaluation of Drainage Improvement Effect Using Geostatistical Analysis in Poorly Drained Sloping Paddy Soil)

  • 정기열;윤을수;박기도;박창영
    • 한국토양비료학회지
    • /
    • 제43권6호
    • /
    • pp.804-811
    • /
    • 2010
  • 경사지 논토양에서 밭작물 재배확대를 위한 합리적인 배수개선 방법을 개발하기 위하여 "배수불량"인 경사지 논토양 (경사 7-15%, 지산통)을 대상으로 배수조건에 따라 "매우불량"인 논 2개 필지, "약간불량"인 논 2개 필지의 논둑아래 기저부에 1열로 명거 (겉도랑 배수), 비닐차단막, 암거 (속도랑 배수), 관다발 등 네 가지 종류의 배수시설을 설치하여 공간상의 위치에 대한 상관관계를 분석하는 지구통계적 방법 (Geostatistical methods)를 이용하여 저비용의 실용적 배수방법을 개발하기 위해 배수개선 방법에 따른 배수개선 효과를 비교 분석하여 다음과 같은 결론을 얻었다. TDR 이용하여 측정한 배수방법별 토양수분함량의 기술통계량을 분석한 결과 배수개선 방법별 평균수분함량은 명거배수 (36.17 mm), 비닐차단막 (32.87 mm), 관다발 (28.71 mm), 암거배수 (23.21 mm) 순으로 낮은 경향을 보였으며, 또한 암거배수 처리구에서의 변이계수가 13.0%로 명거배수 (23.4%), 비닐차단막 (22.2%), 관다발 (15.1%)에 비해 포장 내에서 수분함량이 균일한 것으로 나타났다. 토양수분함량의 이론적 반베리오그램을 분석한 결과 배수등급별 문턱값 (sill)은 배수가 약간불량지에 비해 매우 불량지에서 배수개선 방법별 차이가 뚜렷하였으며, 특히 배수 매우불량지의 암거배수 처리구에서 문턱값은 9.7로 명거배수 (86.2), 비닐차단막 (66.8), 관다발 (15.7)에 비해 낮아 변이가 적고 균일성이 높아 암거배수에 의한 배수개선 효과가 큰 것으로 나타났다. 따라서 "배수불량"인 경사지 논에서는 논둑 밑 1열의 암거배수시설을 설치로 논에서 밭작물의 안정적인 생산과 농지자원의 이용전환 즉 논을 밭으로 이용해야 하는 범용농지 기반조성에 조성을 위한 저비용의 실용적인 배수개선 방법개발에 기여할 것으로 본다.