• 제목/요약/키워드: module system

검색결과 6,639건 처리시간 0.035초

Signal integrity analysis of system interconnection module of high-density server supporting serial RapidIO

  • Kwon, Hyukje;Kwon, Wonok;Oh, Myeong-Hoon;Kim, Hagyoung
    • ETRI Journal
    • /
    • 제41권5호
    • /
    • pp.670-683
    • /
    • 2019
  • In this paper, we analyzed the signal integrity of a system interconnection module for a proposed high-density server. The proposed server integrates several components into a chassis. Therefore, the proposed server can access multiple computing resources. To support the system interconnection, among the highly integrated computing resources, the interconnection module, which is based on Serial RapidIO, has been newly adopted and supports a bandwidth of 800 Gbps while routing 160 differential signal traces. The module was designed for two different stack-up types on a printed circuit board. Each module was designed into 12- (version 1) and 14-layer (version 2) versions with thicknesses of 1.5T and 1.8T, respectively. Version 1 has a structure with two consecutive high-speed signal-layers in the middle of two power planes, whereas Version 2 has a single high-speed signal placed only in the space between two power planes. To analyze the signal integrity of the module, we probed the S-parameters, eye-diagrams, and crosstalk voltages. The results show that the high-speed signal integrity of Version 2 has a better quality than Version 1, even if the signal trace length is increased.

문화위성계정 체계 (System of Culture Satellite Account)

  • 김지영
    • Communications for Statistical Applications and Methods
    • /
    • 제17권6호
    • /
    • pp.879-889
    • /
    • 2010
  • 본 논문은 국민계정의 문화부문 위성계정인 문화위성계정의 체계와 우리나라가 문화위성계정을 작성하기 위해 필요한 사항 등을 내용으로 한다. 문화위성계정은 각기 개별적 기능을 갖는 5개 부문으로 구성하도록 권고되고 있다. 동 권고안에 의하면 제 1부문부터 제 4부문까지는 각각 해당부문의 공급과 수요측면의 통계를 수록하도록 되어 있고, 제 5부문은 참고사항 모듈(documentation module)로 편제하도록 권고되고 있다. 문화위성계정의 제 1부문은 문화활동 개요 모듈(macro-information module), 제 2부문은 문화생산량 모듈(quantity/volume output module), 제 3부문은 특성 모듈(characterization module), 제 4부문은 목표분석 모듈(targeted analysis/analytical module)로 구성된다.

지능형 교수 시스템 지원을 위한 멀티미디어 인터페이스의 설계 (Design of Multimedia Interface for Intelligent Tutoring System)

  • 정상목;이완복
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2006년도 추계 종합학술대회 논문집
    • /
    • pp.575-579
    • /
    • 2006
  • 지능형 교수 시스템의 주요 구성 요소인 교수 모듈, 학습자 모듈, 전문가 모듈, 인터페이스 모듈 중에서 학습자와 가장 긴밀한 연관이 있으며 학습 시스템의 가장 큰 표현 부분에 해당하는 모듈이 인터페이스 모듈이다. 학습자에게 있어 인터페이스 모듈은 일반 이러닝 시스템뿐만 아니라 지능형 교수 시스템에서도 큰 비중을 차지하는데 아직까지 인터페이스의 개선에 관한 연구는 그리 활발하지 못한 실정이다. 이에 따라 본 연구에서는 이러닝시 학습자와 가장 상호작용이 많은 인터페이스의 개선에 관한 연구를 수행하였다. 본 연구를 위해 기존의 인터페이스의 주요 구성 요소에 대해 살펴보았으며 선행 연구의 문제점을 개선한 멀티미디어 인터페이스를 설계 구현 하였다.

  • PDF

원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발 (Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method)

  • 류재규;손창호;황희정;김건수;최경식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

옥상녹화가 PV모듈 발전량에 미치는 영향 고찰 (A study on the effect that the green roof has on the performance of PV module)

  • 유동철;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.113-119
    • /
    • 2012
  • This study aims to examine the effect of the combined application of green roof and PV system on the PV efficiency by measuring the temperature and performance of PV module in order to reduce the temperature on the roof using roof planting system and determine the potential of efficient increase in solar-light power generation. In the experimental methodology, either monocrystalline or polycrystalline PV module was installed in green roof or non-green roof, and then the surface temperature of PV was measured by TR-71U thermometer and again the performance, module body temperature, and conversion efficiency were measured by MP-160, TC selector MI-540, and PV selector MI-520, respectively. As a result, the average body temperature of monocrystalline module was lower by $6.5^{\circ}C$ in green roof than in non-green roof; that of polycrystalline module was lower by $8.8^{\circ}C$ in green roof than in non-green roof. In the difference of generation, the electricity generation of monocrystalline module in green roof was 46.13W, but that of polycrystalline module was 68.82 W, which indicated that the latter produced 22.69W more than the former.

지붕 설치형 결정질 실리콘 태양전지모듈의 온도 특성 (Roof-attached Crystalline Silicon Photovoltaic Module's Thermal Characteristics)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.11-18
    • /
    • 2012
  • To expect accurately the maximum power of solar cell module under various installation conditions, it is required to know the performance characteristics like temperature dependence. Today, the PV (photovoltaic) market in Korea has been growing. Also BIPV (building integrated photovoltaic) systems are diversified and become popular. But thermal dependence of PV module is little known to customers and system installers. In IEC 61215,a regulation for testing the crystalline silicon solar cell module, the testing method is specified for modules. However there is limitation for testing the module with diverse application examples. In extreme installation method, there is no air flow between rear side of module and ambient, and it can induce temperature increase. In this paper, we studied the roof type installation of PV module on the surface of one-axis tracker system. We measured temperature on every component of PV module and compared to open-rack structure. As a result, we provide the foundation that explains temperature characteristics and NOCT (nominal operation cell temperature) difference. The detail description will be specified as the following paper.

대규모 시스템의 실시간 컴퓨터 제어를 위한 전문가 시스템 (An Expert System for the Real-Time Computer Control of the Large-Scale System)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.781-788
    • /
    • 1999
  • In this paper, an expert system is proposed, which can be effectively applied to the large-scale systems with the diversity time constraints, the objectives and the unfixed system structure. The inference scheme of the expert system have the integrated structure composed of the intuitive inference module and logical inference module in order to support effectively the operating constraints of system. The intuitive inference module is designed using the pattern matching or pattern recognition method in order to search a same or similar pattern under the fixed system structure. On the other hand, the logical inference module is designed as the structure with the multiple inference mode based on the heuristic search method in order to determine the optimal or near optimal control strategies satisfing the time constraints for system events under the unfixed system structure, and in order to use as knowledge generator. Here, inference mode consists of the best-first, the local-minimum tree, the breadth-iterative, the limited search width/time method. Finally, the application results for large-scale distribution SCADA system proves that the inference scheme of the expert system is very effective for the large-scale system. The expert system is implemented in C language for the dynamic mamory allocation method, database interface, compatability.

  • PDF

힘 및 변위 감지기구를 적용한 초정밀 가공시스템 개발 (Development of an Ultra Precision Machining System Using a Force and Displacement Sensing Module)

  • 방진혁;권기환;조남규
    • 한국정밀공학회지
    • /
    • 제22권12호
    • /
    • pp.42-50
    • /
    • 2005
  • This paper presents an ultra precision machining system using a high sensitive force sensing module to measure machining forces and penetration displacement in a tip-based nanopatterning. The force sensing module utilizes a leaf spring mechanism and a capacitive displacement sensor and it has been designed to provide a measuring range from 80 ${\mu}N$ to 8 N. This force sensing module is mounted on a PZT driven in-feed motion stage with 1 nm resolution. The sample can be moved by X-Y scanning motion stage with 5 nm resolution. In nano indentation experiments and patterning experiments, the machining forces were controlled and monitored by the force sensing module. Then, the patterned samples were measured by AFM. Experimental results demonstrated that the developed system can be used as an effective device in nano indentation and nanopatterning operation.

산업용 EMS를 고려한 누설전류 센싱 컨트롤러의 개발 (Development of Leakage Current Sensing Controller in Consideration of Industrial EMS)

  • 박성원;노인배;김상동;박지호;김동완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.70-71
    • /
    • 2009
  • In recent years, a importance of EMS(Electromagnetic Susceptibility) is increased with the spread of a communication device significantly. The compatibility of EMS is evaluated by conduction and radiation of EMI(Electromagnetic Interference). In this paper, a leakage current sensing controller which is considered of industrial EMS is developed. The developed system is consisted of power module, sensing module of leakage current, processer module, display module and communication module. The developed system is evaluated the compatibility of EMS by conduction and radiation of EMI. In evaluation results, the developed system is compatible to the standard of industrial EMS.

  • PDF

FMS의 생산계획 및 일정계획을 위한 단계적 해법에 관한 연구 (Hierarchical approaches for the FMS production planning and scheduling problems)

  • 장성용;박진우
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1990년도 춘계공동학술대회논문집; 한국과학기술원; 28 Apr. 1990
    • /
    • pp.195-208
    • /
    • 1990
  • Flexible Manufacturing System(FMS) is an integrated, computer controlled complex of automated material handling devices and numerically controlled machine tools that can simultaneously process medium-sized volumes of a variety of part types. This paper discusses planning problems that can be solved for efficient use of an FMS and present an integrated decision support system for FMS production planning and scheduling problems. FMSDS(Flexible Manufacturing Systems Decision Support System) consists of data handling modules, part selection module, loading module, load adjusting module, scheduling module and simulation module etc. This paper presents the solution methodology of each subproblems and integrated interfaces between subproblems using hierarchical approaches and loop controls considering the relationships between subproblems. A case study by this model is presented.

  • PDF