• Title/Summary/Keyword: module efficiency

Search Result 1,274, Processing Time 0.029 seconds

The Study on Evaluating Performances of Lab Sacle-Advanced $A_{2}O$ with Changing System Using Biofilm Process (생물막 담체를 이용한 실험실 규모 $A_{2}O$공법의 시스템 변형에 따른 고도처리 성능 평가에 관한 연구)

  • Kim, Min-Sik;Kang, Gu-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.209-218
    • /
    • 2012
  • Recently, as reinforced water quality standards for wastewater has been announced, more efficient and more powerful wastewater treatment processes are required rather than the existing activated sludge process. In order to meet this demands, we evaluate Task 1-4 about lab scale $A_{2}O$ process using biofilm media. Task 1, 2, and 3 use 'Module A' which has 4 partitions (Anoxic/Anerobic/Oxic/Oxic). Task 4 uses 'Module B' which has 2 partitions including a denitrification reactor with an Inclined plug flow reactor (IPFR) and a nitrification reactor with biofilm media. The denitrification reactor of Module B is designed to be upward flow using IPFR. The result of evaluating at each Task has shown that attached growth system has better capacity of removal efficiency for organic matter and nitrogen with the exception of phosphorus. Task 4 which has the most outstanding removal efficiency has 90.5% of $BOD_{5}$ removal efficiency, 97.8% of ${NH_4}^{+}-N$ removal efficiency, 65% of T-N removal efficiency and 92% of T-P removal efficiency with additional chemical phosphorus removal system operated at HRT 9hr, Qi:Qir 1:2, and BOD/T-N ratio 2.7.

HC-06 Bluetooth based driver module for emergency LED Multi-Directional Indicator

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.114-119
    • /
    • 2017
  • In this paper we present the search on HC-06 Bluetooth based driver module for emergency LED Multi-Directional Indicator. Nowadays, a growing trends in which electronic displays such as LED, LCD or plasma monitors are being installed in public places like bars, stores, entertainment areas, restaurants, lobbies, etc. In this paper, the study is curried out on efficiency of HC-06 Bluetooth module based controller driver that relates generally to the field of emergency signage management systems for displaying various indicator contents remotely on electronic displays in public and privates venues. It allows user smart devices interaction remotely with digital signage by providing content for displaying on at least one display in a venue. Depending on the emergency case, HC-06 Bluetooth based driver module proves the high efficiency as well as good performance of processing and communicating remotely the indicator based message that is displayed from a venue management control system by using smart devices. The system combines smart device that linked to HC-06 Bluetooth module with ATmega168/328 embedded micro controller which result by switching the displayer containing the digital signage indicator based message.

The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules (액체식 PVT 복합모듈의 유형별 성능 비교 분석)

  • Kim, Jin-Hee;Kang, Jun-Gu;Kim, Jun-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.792-797
    • /
    • 2009
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.

  • PDF

Performance Measurement Method of Several Types of Photovoltaic Module Depending on Efficiency (고효율 태양전지모듈의 성능측정 방법)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Yoon, Soon-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.93-99
    • /
    • 2011
  • To guarantee more exact maximum power of solar cell module, it is absolutely required to have performance characteristics of various solar cells. Today, there are many types of solar simulator for large area measurement. But it is very opaque how to select the best one for various solar cell module like crystalline silicon solar cell, high efficiency solar cell, amorphous silicon thin film solar cell, CdTe and CIGS solar cell module. So, in this paper 4 types of photovoltaic module were selected to compare the electrical characteristics by changing light pulse duration time and voltage scan direction. Light pulse duration time was varied from 10msec to 800msec. And two types of voltage scan directions, Voc->Isc and Isc->Voc were selected. From this results, optimum measuring condition was suggested and electrical variation was analysed for each types of solar cell module. The detail description is specified as the following paper.

Interface Module Developement of Structural Design for Brace Connections on based BIM (BIM기반의 브레이스 접합부의 구조설계 인터페이스 모듈 개발)

  • Kim, Tae Hyeong;Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.2
    • /
    • pp.197-207
    • /
    • 2013
  • This study is aimed at developing the structural design interface module for the brace connections in order to improve the efficiency of the interoperability between structural design and BIM modeling at the construction design phase of steel structures. For this purpose, structural design module is first established according to the algorithm built by structural design standards of domestic and foreign. Then, it is developed interface module which can export the data of 3D model obtained from the BIM design tools to structural design module and feed structural design results back to 3D BIM model. Finally, the efficiency and practicality of the developed interface module is verified by applying to a sample model.

Research on operation stability of 7kW Inverter for short distance vehicle using SiC Hybrid module (SiC 하이브리드 모듈을 적용한 근거리용 7kW Inverter 동작 안정성에 대한 연구)

  • Jeon, Joon-Hyeok;Kyoung, Sin-Su;Kim, Hee-Jun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.5
    • /
    • pp.499-506
    • /
    • 2019
  • This paper is concerned with the operating stability of 7kW inverter using SIC hybrid module and verifies the validity of the simulation results by comparing the result of the loss equation and the simulation result, Simulation results using Si module and SiC hybrid module are compared to compare switch loss and diode loss. Through the loss equation calculation, the conduction loss of SiC Hybrid module is 168W, switching loss is 9.3W, diode loss is 10.5nW, When compared with the simulation results, similar values were shown. As a result of comparing the simulation results of the Si module and the SiC Hybrid module, The total device loss of the Si module was 246.2W, and the total device loss of the SiC Hybrid module was 189.9W. The loss difference was 56.3W, which was about 0.8W. thereby verifying the reverse recovery characteristics of the SiC SBD. In addition, temperature saturation test was conducted to confirm the stability of SiC Hybrid module and Si module under high temperature saturation, In the case of the Si module, the output power was stopped at 4kW, and the SiC Hybrid module was confirmed to operate at 7kW. Based on this, an efficiency graph and a temperature graph are presented, and the Si module is graphed up to 4kW and the SiC Hybrid module is graphed up to 7kW.

The Analysis of the Effects of Design Parameters on the Energy Efficiency and Performance of TEM Dehumidifiers (열전모듈 제습기의 에너지 효율과 성능에 미치는 설계 인자의 영향 분석)

  • Lee, Tae-Hee
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2020
  • To provide a design direction for high efficiency thermoelectric module(TEM) dehumidifiers, the effects of design factors of TEM dehumidifiers on dehumidification energy efficiency and performance were numerically investigated. The design factors considered in this study are the TEM capacity, the performance of heat exchangers on the heating and cooling surfaces of the TEM. The higher capacity of the TEM results the higher dehumidification energy efficiency and performance at some operating voltage. The enhanced performance of the heat exchanger on heating surface increased the dehumidification energy efficiency and performance at all the operating voltage. The enhanced performance of the heat exchanger on cooling surface decreased the dehumidification energy efficiency and performance at all operating voltage.

Hardware Implementation of HEVC CABAC Binarizer

  • Pham, Duyen Hai;Moon, Jeonhak;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.356-361
    • /
    • 2014
  • This paper proposes hardware architecture of HEVC (high efficiency video coding) CABAC (context-based adaptive binary arithmetic coding) binarizer. The proposed binarizer was designed and implemented as an independent module that can be integrated into HEVC CABAC encoder. It generates each bin string of each syntax element in a single cycle. It consists of controller module, TU (truncated unary binarization) module, TR (truncated Rice binarization) module, FL (fixed length binarization) module, EGK (k-th order exp-Golomb coding) module, CALR (coeff_abs_level_remaining) module, QP Delta (cu_qp_delta_abs) module, Intra Pred (intra_chroma_pred_mode) module, Inter Pred (inter_pred_idc) module, and Part Mode (part_mode) module. The proposed binarizer was designed in Verilog HDL, and it was implemented in 45 nm technology. Its operating speed, gate count, and power consumption are 200 MHz, 1,678 gates, and 50 uW, respectively.

Development of CAD/CAM System with Reusable Design Information for Improving Production Efficiency (생산효율의 향상을 위한 설계정보의 재사용이 가능한 CAD/CAM 시스템 개발)

  • Kang, Bong Ku;Lee, Jong Hang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.7
    • /
    • pp.597-604
    • /
    • 2014
  • High efficiency production requires the improved performance of CAD/CAM system. Although the CAD and CAM have been significantly developed over the last three decades, they must still study on the reuse of information during process. In this study, we developed a new integrated CAD/CAM system which can reuse the information generated in previous processes, in order to improve its performance. In addition, the developed system was verified by comparing with working-time, and system reproducibility was also examined with tolerance in the unmanned operation. Experimental results showed 58% reduction in working-time of 2D Auto-CAM module, 80% in case of 3D Auto-Exchange module, and 54.5% in case of Auto-Design module.

A New Controllable Active Clamp Algorithm for Switching Loss Reduction in a Module Integrated Converter System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.465-471
    • /
    • 2014
  • This paper proposes a new switching algorithm for an active clamp snubber to improve the efficiency of a module integrated converter system. This system uses an active clamp method for the snubber circuit for the efficiency and reliability of the system. However, the active clamp snubber circuit has the disadvantage that system efficiency is decreased by switch operating time because of heat loss in resonance between the snubber capacitor and leakage inductance. To address this, this paper proposes a new switching algorithm. The proposed algorithm is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time. Also, the snubber switch is operated at zero voltage switching by turning on the snubber switch before main switch turn-off. Simulation and experimental results are presented to show the validity of the proposed new active clamp control algorithm.