• Title/Summary/Keyword: module combination

Search Result 230, Processing Time 0.029 seconds

Design and Implementation of a Virtual MCU Based on SystemC to Provide the Implementation Environment of MAC Layer Software (MAC 계층 소프트웨어의 구현 환경을 제공하기 위한 SystemC 기반의 가상 MCU 모듈의 설계 및 구현)

  • Jeong, Yoo-Jin;Park, Soo-Jin;Lee, Ho-Eung;Park, Hyun-Ju
    • Journal of Internet Computing and Services
    • /
    • v.10 no.6
    • /
    • pp.7-17
    • /
    • 2009
  • The development of wireless communication MAC layer is usually released as SoC which is a combination in hardware and software. In this system development environment, an environment for software development and verification is necessary because the hardware development takes a lot of time priori to completion. In integrated development of hardware and software, simulation environment of hardware and software provided by hardware modeling using HDL at RTL and ISS respectively. By increasing the development complexity of system, ESL design modeling systems at higher abstraction level than RTL has already prompted. The ESL design is divided untime model and time model. This paper present design and implementation of MCU for untime model simulation, not time model. Proposed MCU can optimize the system at early step of system development and move up the development completion time by verifying the system function easily and rapidly than part required exact time in untime model. In this paper, we present an MCU module based on SystemC and UC/OS-II Module providing real-time operate system.

  • PDF

A low noise, wideband signal receiver for photoacoustic microscopy (광음향 현미경 영상을 위한 저잡음 광대역 수신 시스템)

  • Han, Wonkook;Moon, Ju-Young;Park, Sunghun;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.507-517
    • /
    • 2022
  • The PhotoAcoustic Microscopy (PAM) has been proved to be a useful tool for biological and medical applications due to its high spatial and contrast resolution. PAM is based on transmission of laser pulses and reception of PA signals. Since the strength of PA signals is generally low, not only are high-performance optical and acoustic modules required, but high-performance electronics for imaging are also particularly needed for high-quality PAM imaging. Most PAM systems are implemented with a combination of several pieces of equipment commercially available to receive, amplify, enhance, and digitize PA signals. To this end, PAM systems are inevitably bulky and not optimal because general purpose equipment is used. This paper reports a PA signal receiving system recently developed to attain the capability of improved Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of PAM images; the main module of this system is a low noise, wideband signal receiver that consists of two low-noise amplifiers, two variable gain amplifiers, analog filters, an Analog to Digital Converter (ADC), and control logic. From phantom imaging experiments, it was found that the developed system can improve SNR by 6.7 dB and CNR by 3 dB, compared to a combination of several pieces of commercially available equipment.

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

Implementation of Motion Analysis System based on Inertial Measurement Units for Rehabilitation Purposes (재활훈련을 위한 관성센서 기반 동작 분석 시스템 구현)

  • Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • In this paper, we present an inertial sensor-based motion capturing system to measure and analyze whole body movements. This system implements a wireless AHRS(attitude heading reference system) we developed using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. We performed 3D motion capture using the quaternion data calculated. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE of 2.56 degree. The results suggest that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limbs or gait analysis during the post-stroke recovery process.

  • PDF

Evaluation of Clinical Utility and Biologic False Positive (BFP) Rates in Automated Syphilis Test Kits for Syphilis Screening (자동화 매독검사 키트의 임상적 유용성 및 생물학적 위양성률의 평가)

  • Kim, Sung-Man;Lee, Jehoon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.42-46
    • /
    • 2009
  • Unlike most bacteria, Treponema pallidum subspecies cannot be readily isolated or sustained in cell culture for numerous generations. In korea, two non treponemal tests are currently considered as standard; the VDRL slide test and RPR card test. These tests are based on an antigen composed of an alcoholic solution containing measured amount of cardiolipin, cholesterol, and sufficient purified lecithin to produce reactivity. The nontreponemal reagin tests measure immunoglobulin M (IgM) and IgG to lipoidal material released from damaged host cells as well as to lipoprotein-like material and possibly by cardiolipin released from the treponemes. The object of the evaluation was to evaluate the performance of the Mediace RPR kit on the automated biochemistry analyzer system as a method for screen method of syphilis as well as to identify BFP possibility. For evaluation of routine screening test, a total 2,380 specimens tested by Mediace RPR from 28th Oct, 2007 to 22th Feb, 2008. For evaluation of BFP possiblility, we measured samples which have potential BFP reaction in Syphilis test such as ANA (anti-nuclear antibody) positive (135 samples), CRP (C-reactive protein) positive (100 samples), RF (Rheumatoid factor) positive (26 samples), and other potential BFP cases (17 samples) including total 278 samples. These samples were tested quantitative test Mediace RPR with Hitachi 7600 P module. For comparison with current manual test, VDRL slide test were performed. Of these 2380 specimens, 2350 were negative, 30 were positive, and one were positive with TPHA. Both methods agreed for 2356 (98.9%) samples. Of the 30 samples showed positive results over 1.0 R.U, 6 samples showed positive results with VDRL test. Of these 6 samples, 1 samples showed positive with TPHA test. The combination of the Automated Biochemistry analyzer and VDRL test for retest can be increase efficiency of syphilis screening test.

  • PDF

Mobile Remote Healthcare in Ubiquitous Computing Environments (유비쿼터스 환경에서 모바일을 이용한 원격 헬스케어)

  • Kang, Eun-Young;Im, Yong-Soon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.55-61
    • /
    • 2008
  • In this paper, we proposed a multi-agent based healthcare system (MAHS) which is the combination of medical sensor module and wireless communication technology. This MAHS provides wide services to mobile telemedicine, patient monitoring, emergency management, doctor's diagnosis and prescription, patients and doctors, information exchange between hospital workers in a long distance. Also, MAHS is connected to Body Area Network (BAN) and a doctor and hospital workers. In addition, we designed and implemented extended JADE based MAHS that reduces hospital server's burden. Agents gather, integrate, and deliver the collected patient's information from sensor, and provide presentation in healthcare environment. Proposed MAHS has advantage that can handle urgent situation in the far away area from hospital like Islands through PDA and mobile device. In addition, by monitoring condition of patient (old man) in a real time base, it shortens time and expense and supports medical service efficiently.

  • PDF

Performance Evaluation of MF Membrane Filtration Pilot System Associated with Pre Coagulation-Sedimentation with Iron-Based Coagulant and Chlorination Treatment (철염계 응집제를 사용한 전응집침전, 전염소처리와 PVDF 재질의 정밀여과 막을 조합한 막 여과 정수처리시스템 평가에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Yoshimasa, Watanabe;Choi, Yongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.588-597
    • /
    • 2004
  • In this research, we investigated the variation of transmembrane pressure and permeate water quality with pre coagulation and sedimentation with iron based coagulant and chlorination of feed water for PVDF (polyvinylidene fluoride) based MF membrane filtration. NaCIO was fed to the membrane module with dosage of 0.5mg/L and maintained during filtration. To observe the effect of raw water, three types of raw and processed waters, including river surface water, coagulated water and coagulated-settled water, were applied. In case of river surface water, the transmembrane pressure increased drastically in 500 hours of operation. On the contrary, no significant increase in transmembrane pressure was observed for 1,200 hours of operation for coagulated water and coagulated-settled waters. The turbidity of permeate was lower than a detection limit of equipment for all raw waters. The removal efficiency of humic substances of coagulated water and coagulated-settled water was approximate ten times of that of surface river water. And, the removal efficiency of TOC and DOC was approximate two times of that of surface river water. From the results of plant operation, stable operation was maintained at $0.9m^3/m^2{\cdot}day$ filtration flux through the combination of pre-coagulation and pre-chlorination. However, the water quality of permeate was the best when pre-coagulation-sedimentation process was combined with pre-chlorination.

Composition Principle of Seo-Won Architecture from the View of Its Disposition and Korean Traditional Thought (전통사상(專統思想)과 서원건축배치(書院建築配置)의 구성(構成) 원리(原理))

  • Park, Jeomg-Hae;Han, Dong-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.6
    • /
    • pp.33-43
    • /
    • 2011
  • The Korean academics of classical learning, Seowon which from the middle of Joseon Dynasty was complexly reflected in "the illustration of Taiji(太極圖說)" Five-Elements school(陰陽五行說), "Zhou Yi(周易)" and a theory on spherical heaven and square ground(天圓地方) which based on orientalism. Also the theory of Xiangshu Xue(象數學) was a significant factor to decide the size(number of facade module) of Seowon architecture. So, in this study, how the oriental thought was adopted and reflected in existing 21 Seowon in South Korea. The size of Seowon architecture was adopted a theory of combination with heaven, earth and human(天地人三合論) that based on the theory of Xiangshu Xue on "the illustration of Taiji" and "Zhou Yi". "Zhou Yi" was the central thought of Confucian culture in Joseon Dynasty, with which Seowon space was divided into two, ancestral rites space and lecture space. It coincides with balance of yin(陰) and yang(陽), Five-Elements(五行) and four seasons(四季節). In lecture space, lecture hall is relevant with the water(水) and winter, and front tower structure or outer three-door is the fire(火) and summer. Also, central garden means the soil(土) and center. Thus, the size and spatial composition was planned with the philosophy, "the illustration of Taiji", Five-Elements school and a theory on spherical heaven and square ground. Yin and yang has an idea of the heaven and earth, and Five-Elements has an idea of direction and season with which spatial composition of Seowon could be set. And the numeral meaning on the theory of Xiangshu Xue established an ideal background for spatial composition of Seowon architecture.

  • PDF

Humanoid Robot Performance System for Performing in Public Places (공공장소에서 공연을 위한 휴머노이드 로봇 공연 시스템)

  • Hwang, Heesoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.190-196
    • /
    • 2016
  • This paper proposes a humanoid robot performance system for performing in public places, such as an event, exhibition, or street performance. The system of modular structures can be moved easily, and can be played by a module or a combination of modules. The system developed with open source-based software and hardware is easy to adapt and improve. The robot performance control program for controlling robots, displays, audios, videos, and performance instruments was developed using the open source language, Processing. The performance instruments were developed using the open source hardware, Arduino. The contents of the robot performance were composed of scene-specific image, background audio, computer graphics, and videos. For their control and synchronization, the performance control program communicates with the humanoid robots and the performance instruments. In addition, performance accessories required to represent the performance concepts are produced by 3D modeling and printing. In a public place, the robot performance is performed with the theme of celebrating a Halloween day.

Development of Case-based Multimedia Learning Contents for Preventing Malpractice in Operating Room (수술실 간호오류 예방을 위한 사례중심 멀티미디어 학습콘텐츠 개발)

  • Park, Ji Myung;Hwang, Seon Young
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.522-532
    • /
    • 2016
  • Purpose: This study was conducted to develop case-based self-learning multimedia contents for preventing malpractice that frequently occurred among nurses working in the operating room. Methods: Based on the learning needs of operating room nurses, real case reports, and literature reviews, the case-based multimedia learning contents were developed according to the instructional design procedure. The assessment of learning needs was performed by the combination of surveys using structured questionnaire and of interviews for 40 operating room nurses. Results: The learning contents included four learning modules with real malpractice cases from the areas of operating preparation, nursing skills during operation, environmental management of operating room, and patient safety and observation-related. The 80 minute long case-based multimedia learning contents were finally developed after content validity tests from clinical experts. Each module contained photos, sounds and flash animation with voice recording on the contents of nursing error cases and standardized protocols. Conclusion: The developed multimedia learning contents based on real error cases in this study can be utilized as an educational hands-on training materials for nurses to prevent malpractice in the operating room.