• Title/Summary/Keyword: modulation-transfer function (MTF)

Search Result 207, Processing Time 0.036 seconds

A Study on the Eavesdropping of the Glass Window Vibration in a Conference Room (회의실내 유리창 진동의 도청에 대한 연구)

  • Kim, Seock-Hyun;Kim, Yoon-Ho;Heo, Wook
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.55-60
    • /
    • 2007
  • Possibility of the eavesdropping is investigated on a conference room-glass window coupled system. Speech intelligibility analysis is performed on the eavesdropping sound of the glass window. Using MLS(Maximum Length Sequency) signal as a sound source, acceleration and velocity responses of the glass window are measured by accelerometer and laser doppler vibrometer. MTF(Modulation Transfer Function) is used to identify the speech transmission characteristics of the room and window system. STI(Speech Transmission Index) is calculated by using MTF and speech intelligibility of the vibration sound is estimated. Speech intelligibilities by the acceleration signal and the velocity signal are compared.

  • PDF

Design and Performance Verification of a LWIR Zoom Camera for Drones

  • Kwang-Woo Park;Jonghwa Choi;Jian Kang
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.354-361
    • /
    • 2023
  • We present the optical design and experimental verification of resolving performance of a 3× long wavelength infrared (LWIR) zoom camera for drones. The effective focal length of the system varies from 24.5 mm at the wide angle position to 75.1 mm at the telephoto position. The design specifications of the system were derived from ground resolved distance (GRD) to recognize 3 m × 6 m target at a distance of 1 km, at the telephoto position. To satisfy the system requirement, the aperture (f-number) of the system is taken as F/1.6 and the final modulation transfer function (MTF) should be higher than 0.1 (10%). The measured MTF in the laboratory was 0.127 (12.7%), exceeds the system requirement. Outdoor targets were used to verify the comprehensive performance of the system. The system resolved 4-bar targets corresponding to the spatial resolution at the distance of 1 km, 1.4 km and 2 km.

Study of Image Properties for Computed Radiography (Computed Radiography의 영상특성에 관한 연구)

  • Ryu, Ki-Hyun;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

Baseline Correction in Computed Radiography Images with 1D Morphological Filter (CR 영상에서 기저선 보정을 위한 1차원 모폴로지컬 필터의 이용에 관한 연구)

  • Kim, Yong-Gwon;Ryu, Yeunchul
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.397-405
    • /
    • 2022
  • Computed radiography (CR) systems, which convert an analog signal recorded on a cassette into a digital image, combine the characteristics of analog and digital imaging systems. Compared to digital radiography (DR) systems, CR systems have presented difficulties in evaluating system performance because of their lower detective quantum efficiency, their lower signal-to-noise ratio (SNR), and lower modulation transfer function (MTF). During the step of energy-storing and reading out, a baseline offset occurs in the edge area and makes low-frequency overestimation. The low-frequency offset component in the line spread function (LSF) critically affects the MTF and other image-analysis or qualification processes. In this study, we developed the method of baseline correction using mathematical morphology to determine the LSF and MTF of CR systems accurately. We presented a baseline correction that used a morphological filter to effectively remove the low-frequency offset from the LSF. We also tried an MTF evaluation of the CR system to demonstrate the effectiveness of the baseline correction. The MTF with a 3-pixel structuring element (SE) fluctuated since it overestimated the low-frequency component. This overestimation led the algorithm to over-compensate in the low-frequency region so that high-frequency components appeared relatively strong. The MTFs with between 11- and 15-pixel SEs showed little variation. Compared to spatial or frequency filtering that eliminated baseline effects in the edge spread function, our algorithm performed better at precisely locating the edge position and the averaged LSF was narrower.

Image Quality Evaluation of Digital X-ray Image and Film Image using Contrast Method (Contrast Method를 이용한 디지털 X선 영상과 필름 영상의 영상 질(Quality) 평가)

  • Park, Ji-Koon;Jung, Bong-Jae;Choi, Jang-Yong;Kang, Sang-Sik
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this paper, an image quality evaluation of amorphous selenium based x-ray system was performed using modulation transfer function (MTF) measurement. MTF as a main factor of imaging quality evaluation was investigated by contrast method from acquired test pattern image. The MTF value was measured to 36.1% at 3.0 lp/mm which is twice as high as that in the film image. Compared with other studies, the results demonstrate that amorphous selenium based x-ray detector is clinically meaningful.

MTF and wavefront error testing of large aperture optical system using unequal path interferometer (경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사)

  • Song, Jong-Sup;Jo, Jae-Heung;Lee, Yun-Woo;Song, Jae-Bong;Yang, Ho-Soon;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2005
  • A method for measuring the wavefront error and the modulation transfer function(MTF) of large aperture optics using an unequal path interferometer is presented. A bidirectional shearing interferometer is used for collimation testing of the measurement system. A large aperture Fizeau interferometer with long optical path difference measures the wavefront error of the optics under test by using a $\Phi$ 400 mm off-axis parabolic mirror. The MTF is also measured at the wavelength of the interferometer by changing the laser light into partially incoherent light. Test results of a $\Phi$ 300 mm Cassegrain type satellite telescope made in Korea are presented.

Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom (컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.193-198
    • /
    • 2016
  • In clinical computed tomography (CT), regular quality assurance (QA) has been required. This study is to evaluate the MTF for analyzing the spatial resolution using AAPM phantom in CT exam. The dual source somatom definition flash (siemens healthcare, forchheim, Germany), the brilliance 64 (philips medical system Netherlands) and aquilion 64 (toshiba medical system, Japan) were used in this study. The quantitative evaluation was performed using the image J (wayne rasband national institutes of health, USA) and chart method which is measurement of modulation transfer function (MTF). In MTF evaluation, the spatial frequencies corresponding to the 50% MTF for the CT systems were 0.58, 0.28, and $0.59mm^{-1}$, respectively and the 10% MTF for the CT systems were 1.63, 0.89, and $1.21mm^{-1}$, respectively. This study could evaluate the characteristic of spatial resolution of MTF using chart method, suggesting the quantitative evaluation method using the data.

Development of Image Quality Evaluation Program for Digital Diagnostic Radiography (디지털진단의료영상 화질평가 프로그램 개발)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.5-10
    • /
    • 2008
  • Most of the diagnostic medical radiography are rapidly replaced by digital imaging systems recently. Although with the current transition of analog to digital most of the exposure conditions and parameters are still on the basis of film-screen analog system. Moreover the evaluation of acquired digital radiographic image is not fulfilled normally because of the difficulties in handling the digital raw data. The user friendly windows program for the evaluations of digital radiographic image was developed on the MatLab platform. The program has functions for the calculation of the contrast profile, NPS(noise power spectrum), MTF(modulation transfer function), and NEQ(noise equivalent quanta).

  • PDF

The Binary Tree Vector Quantization Using Human Visual Properties (인간의 시각 특성을 이용한 이진 트리 벡터 양자화)

  • 유성필;곽내정;박원배;안재형
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.3
    • /
    • pp.429-435
    • /
    • 2003
  • In this paper, we propose improved binary tree vector quantization with consideration of spatial sensitivity which is one of the human visual properties. We combine weights in consideration with the responsibility of human visual system according to changes of three primary color in blocks of images with the process of splitting nodes using eigenvector in binary tree vector quantization. Also we propose the novel quality measure of the quantization images that applies MTF(modulation transfer function) to luminance value of quantization error of color image. The test results show that the proposed method generates the quantized images with fine color and performs better than the conventional method in terms of clustering the similar regions. Also the proposed method can get less quantized level images and can reduce the resource occupied by the quantized image.

  • PDF

Imaging Characteristics of Plastic Scintillating Fiber Screens for Digital Mammography

  • Choi, Won-Young;Walker, James K.;Jing, Zhenxue
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.165-172
    • /
    • 1996
  • A scanning slot digital mammography system Luing a plastic scintillating fiber screen (SFS) is currently being developed To improve the x-ray interaction efficiency and absorption efficiency of an SFS, high Z elements can be added into the scintillating fiber core. In this paper, we investigated theoretically the zero spatial frequency detective quantum efficiency, DQE(0), and modulation transfer function, MTF(f), of three 2 cm thick SFSs made of polystyrene, polystyrene loaded with 5% by weight of lead, and polystyrene Loaded with 10% by weight of tin scintillating fibers. X-ray interaction efficiency, scintillating light intensity distributions and line spread functions were generated using Monte Carlo simulation. DQE(0) and MTF(f) were computed for x-ray energies ranging from 15 to 50 keV. Loading high Z elements into the SFS markedly increased the DQE(0). For x-ray energies used for mammovaphy, DQE(0) values of both high Z element loaded SFSs are about a factor of three higher than the DQE(0) of an Min-R screen. At mammographic x-ray energies, MTF(f) values of all three SFSs are Venter than 50% at 25 Ip/mm spatial frequency, and were found to be dominated by the 20 um individual scintillating fiber diameter used The results show that both hiP DQE(0) and spatial resolution can be achieved with the high Z element loaded SFSs, which make these SFSs attractive for use in a scanning slot detector for digital mammography.

  • PDF