• Title/Summary/Keyword: modular components

Search Result 145, Processing Time 0.028 seconds

A Structural Approach and Deployment of a Substation Automation System (변전소 자동화 시스템의 구성 및 개발 사례)

  • You, Jeong-Sik;Lee, Kwon-Han;Choi, Dae-Hee;Choi, Yong-Bum;Lee, Hak-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.258-260
    • /
    • 2001
  • This paper describes the definition of a substation automation system and presents core components and its layered structure based on the modular approach. Also it introduces the implementation and deployment of our substation automation system which was adopted to the field recently.

  • PDF

Dynamic Characteristics of the Integral Reactor SMART

  • Kim, Tae-Wan;Park, Keun-Bae;Jeong, Kyeong-Hoon;Lee, Gyu-Mahn;Park, Suhn
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.111-120
    • /
    • 2001
  • In this study, a dynamic analysis of the integral reactor SMART (System-integrated Modular Advanced ReacTor) under postulated seismic events is performed to review the response characteristics of the major components. To enhance the feasibility of an analysis model, a detailed finite element model is synchronized with the products of concurrent design activities. The artificial time history, which has been applied to the seismic analysis for the Korean Standard Nuclear Power Plant (KSNP), is chosen to envelop broad site specifics in Korea. Responses in the horizontal direction are found slightly amplified, while those in the vertical direction are suppressed. Since amplified response is monitored at the control element drive mechanism (CEDM), minor design provision is considered to enhance the integrity of the subsystem.

  • PDF

CONTRIBUTION OF HANARO IRRADIATION TECHNOLOGIES TO NATIONAL NUCLEAR R&D

  • Choo, Kee Nam;Cho, Man Soon;Yang, Sung Woo;Park, Sang Jun
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.501-512
    • /
    • 2014
  • HANARO is a multipurpose research reactor located at the Korea Atomic Energy Research Institute (KAERI). Since the commencement of its operation in 1995, various neutron irradiation facilities, such as rabbit irradiation facilities, fuel test loop (FTL) facilities, capsule irradiation facilities, and neutron transmutation doping (NTD) facilities, have been developed and actively utilized for various nuclear material irradiation tests requested by users from research institutes, universities, and industries. Most irradiation tests have been related to national R&D relevant to present nuclear power reactors such as the ageing management and safety evaluation of the components. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently supported national R&D projects relevant to new nuclear systems including the System-integrated Modular Advanced Reactor (SMART), research reactors, and future nuclear systems. This paper documents the current state and utilization of irradiation facilities in HANARO, and summarizes ongoing research efforts to deploy advanced irradiation technology.

Development of Energy Balance Program for Staged-Combustion Cycle of Liquid Rocket Engine (액체로켓엔진 통합 설계를 위한 에너지 발란스 프로그램 개발)

  • Lee, Sang-Bok;Roh, Tae-Seong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.93-97
    • /
    • 2010
  • The energy balance program which can balance the relations among energy, mass flow, pressure in the staged-combustion cycle of the liquid rocket engine has been developed. The modular approach has been chosen for the analysis; the engine cycle consists of the elements from the predefined component analysis program. The engine with the staged-combustion cycle has been decomposed into several principal component modules, such as a thruster chamber, turbopumps, turbines, supply system components and a pre-burner. The program has been verified with comparison of the results to the selected data of the space shuttle main engine.

  • PDF

Optimal redundancy allocation in hierarchical systems using genetic algorithm (유전 알고리즘을 이용한 계층구조 시스템에서의 최적 중복 구조 설계)

  • 윤원영;김종운
    • Journal of Applied Reliability
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Redundancy allocation problems have been considered at single-level systems and it may be the best policy in some specific situations, but not in general. With regards to reliability, it is most effective to allocate the lowest objects, because parallel-series systems are more reliable than series-parallel systems. However, the smaller and lower in the system an object is, the more time and accuracy are needed for duplicating it, and so, the cost can be decreased by using modular redundancy Therefore, providing redundancy at high levels like as modules or subsystems, can be more economical than providing redundancy at low levels or duplicating components. In this paper, the problem in which redundancy is allocated at all level in a series system is addressed, a mixed integer nonlinear programming model is presented and a genetic algorithm is proposed. An example illustrates the procedure.

  • PDF

Development of Surgical Two-wavelegth Nd:YAG Laser (수술용 2파장 펄스형 Nd:YAG 레이저 개발)

  • 윤길원;김홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF

Design of Network-based Automation System for Detecting Metallic Objects in Food and Livestock (식품 및 축산물 금속검출기를 위한 네트워크 기반 자동화 시스템 설계)

  • Hang-Seok Cho;Dongik Lee
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.3
    • /
    • pp.109-116
    • /
    • 2023
  • This paper presents a network-based automation system for the detection of metallic objects in food and livestock. A metal detector is a core equipment used for the inspection required by HACCP. Since the existing metal detectors are manufactured as a single-body equipment, it is difficult to take into account various user requirements for the system. In order to overcome the drawback, this study presents a network-based automation system for metal detector utilizing an industrial fieldbus and modular components. The proposed system can effectively consider the various customer requirements and control schemes. The proposed system can also achieve the improvement in speed and success rate of detecting metallic objects. The effectiveness of the proposed system is demonstrated through a various experiments.

Switching-Level Operation Analysis of MMC-based Back-to-Back Converter for HVDC Application (HVDC 적용을 위한 MMC 기반 Back-to-Back 컨버터의 스위칭레벨 동작분석)

  • Hong, Jung-Won;Jeong, Jong-Kyou;Yoo, Seong-Hwan;Choi, Jong-Yun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1240-1248
    • /
    • 2013
  • This paper describes a switching-level operation analysis of BTB(Back-To-Back) converter for HVDC(high voltage DC) application based on MMC(modular multi-level converter). A switching-level operation analysis for BTB converter is very important to understand the converter operation in detail and check the voltage and current transients in each components. However, the development of switching-level simulation model for the actual size BTB Converter is very difficult because the MMC normally has more than 150 sub-modules for each arm. So, a switching level simulation model for the 11-level MMC-based BTB converter was developed with PSCAD/EMTDC software, which has 12 sub-modules for the positive arm and another 12 sub-modules for the negative arm. The DC-voltage balance algorithm, the circulating-current reduction algorithm, the harmonic reduction algorithm, and the redundancy operation algorithm were included in this simulation model. The developed simulation model can be utilized to analyze the MMC-based BTB converter for HVDC application in switching level and to develop the protection scheme for the MMC-based BTB converter for HVDC application.

A Retrospective Questionnaire Survey on the Clinical Effects of HongYi Pharmacopuncture Monotherapy on Female Lower Urinary Tract Symptoms (홍의약침 단일요법이 여성 하부요로증상에 미치는 임상적 효과에 대한 후향적 설문조사 연구)

  • Hwang, Yun-kyeong;Kim, Yong-soo;Choi, Seung-bae;Kim, Won-ill
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.6
    • /
    • pp.930-943
    • /
    • 2017
  • Objectives: The purpose of this study was to investigate the clinical effects of HongYi pharmacopuncture monotherapy on female voiding dysfunction. Methods: Korean medical practitioners who used HongYi pharmacopuncture to treat female patients complaining of dysuria were surveyed. They performed a retrospective chart review of 31 female patients who visited their Korean medical clinic for dysuria. General characteristics, marital status, urologic medical history, International Prostate Symptom Score (IPSS), International Consultation on Incontinence Modular Questionnaire-Female Lower Urinary Tract Symptoms (ICIQ-FLUTS), and related adverse events were examined. Results: Of 31 cases received, 29 were selected for analysis. Two cases were excluded because treatment was not continued through four weeks. In all cases, IPSS and ICIQ-FLUTS scores were significantly decreased after treatment. Adverse reactions occurred during treatment in four cases. Conclusions: These results suggest that treatment by HongYi pharmacopuncture is effective in improving lower urinary tract symptoms in women. Further studies will be needed for evaluation of clinical responses, to evaluate the safety and efficacy of HongYi pharmacopuncture treatment for female patients complaining of dysuria.

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.