• Title/Summary/Keyword: modified electrodes

Search Result 245, Processing Time 0.024 seconds

Selective Determination of Serotonin on Poly(3,4-ethylenedioxy pyrrole)-single-walled Carbon Nanotube-Modified Glassy Carbon Electrodes

  • Kim, Seul-Ki;Bae, Si-Ra;Ahmed, Mohammad Shamsuddin;You, Jung-Min;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1215-1220
    • /
    • 2011
  • An electrochemically-modified electrode [P(EDOP-SWNTs)/GCE] was prepared by electropolymerization of 3,4-ethylenedioxy pyrrole (EDOP) single-walled carbon nanotubes (SWNTs) on the surface of a glassy carbon electrode (GCE) and characterized by SEM, CV, and DPV. This modified electrode was employed as an electrochemical biosensor for the selective determination of serotonin concentrations at pH 7.4 and exhibited a typical enhanced effect on the current response of serotonin with a lower oxidation overpotential. The linear response was in the range of $1.0{\times}10^{-7}$ to $1.0{\times}10^{-5}$ M, with a correlation coefficient of 0.998 on the anodic current. The lower detection limit was calculated as 5.0 nM. Due to the relatively low currents and difference of potentials in the electrochemical responses of uric acid (UA), ascorbic acid (AA), and dopamine (DA), the modified electrode was a useful and effective sensing device for the selective and sensitive serotonin determination in the presence of UA, AA, and DA.

Experimental Study on the Operation of a Keyhole-Shaped Lens in a Microcolumn

  • Oh, Tae-Sik;Jin, Sang-Won;Choi, Sang-Kuk;Kim, Young-Chul;Kim, Dae-Wook;Ahn, Seung-Joon;Lee, Young-Bok;Kim, Ho-Seob
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.368-372
    • /
    • 2011
  • An advanced microcolumn is proposed which adopts a modified einzel lens structure. The newly designed einzel lens is composed of four electrodes. The two center electrodes are specially designed electrostatic quadrupole (EQ) einzel lenses having keyhole instead of circular apertures. We constructed the advanced microcolumn with the EQ-einzel lenses, and operated the newly designed microcolumn in single lens mode and double-lens mode. The preliminary results show that the EQ-einzel lens can improve the performance of the micro-column for large sample applications.

A Study on the Luminance and Luminous Efficiency Improvement of AC PDP by an Improved Fence Structure Electrode (개량된 Fence전극 구조에 의한 AC PDP의 휘도 및 효율 개선에 관한 연구)

  • Hur, Min-Nyung;Lee, Sung-Hyun;Yu, Chung-Hui;Shin, Jung-Hong;Park, Jung-Hoo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.11
    • /
    • pp.531-535
    • /
    • 2002
  • Nowadays, the most serious problems in ac PDP are high cost and complex manufacturing processes. To solve these problems, fence electrode structure, which eliminates the need for expensive transparent electrodes, has been newly suggested. But it has a lower luminance and luminous efficiency than the conventional stripe type electrode structure. In this study, an improved fence electrode structure has been suggested in order to improve luminance and luminous efficiency. The experimental results show that the luminous efficiency of suggested structure is 25% higher than that of conventional fence electrodes.

Diagnostic Calculation of Trace Calcium Ions in Food Using a DNA doped Sensor

  • Yang, Young-Kyun;Ly, Suw-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.197-203
    • /
    • 2013
  • The diagnostic assay of calcium ion was sought using a modified sensor with square-wave stripping voltammetry (SWSV) and cyclic voltammetry (CV). In this study, simple graphite pencil was used as working, reference, and auxiliary electrodes. By coating the working electrodes with DNA, their sensitivity was very much improved, and good results were yielded. Moreover, clean seawater was used as an electrolyte solution instead of acid and base electrolytes to lessen the expenses involved in the experiment. The analytical optimum conditions were also examined. These conditions were attained at the low detection limit of $0.6ugL^1$. After that, the results were applied to drinking water of milk contain.

A Study of Thermal Performances for Micro Gas Sensor (마이크로 가스센서의 열적 성능에 관한 연구)

  • Joo Young-Cheol;Kim Chang-Kyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.531-537
    • /
    • 2006
  • A lever type $NO_2$ micro gas sensor was fabricated by MEMS technology. In order to heat up the gas sensing material to a target temperature, a micro heater was built on the gas sensor. The sensing material laid on the heater and electrodes and did not contact with the silicon base to minimize the heat loss to the silicon base. The electric power to heat up the gas sensor to a target temperature was measured. The temperature distribution of micro gas sensor was analyzed by a CFD program. The predicted electric power of micro heater to heat up the sensing material to the target temperature showed a good agreement with the measured data. The design of micro gas sensor could be modified to show more uniform temperature distribution and to consume less electric power by optimizing the layout of micro heater and electrodes.

A Study on Thermal Performances of Micro Gas Sensor with Micro Hotplate (마이크로 핫플레이트를 갖는 마이크로 가스센서의 열적성능에 관한 연구)

  • Joo, Young-Cheol;Im, Jun-Hyoung;Lee, Joon-Hun;Kim, C.K.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.278-285
    • /
    • 2006
  • A micro hotplate for micro gas sensor was fabricated by MEMS technology. In order to heat up the gas sensing material to a target temperature, a micro hotplate was built on the gas sensor. The sensing material was deposited on the heater and electrodes, and did not contact with the silicon base to minimize the heat loss to the silicon base. The electric power to heat up the gas sensor was measured. The temperature distribution of micro gas sensor was analyzed by a CFD program. The predicted electric power to heat up th sensing material showed a good agreement with the measured data. The design of micro gas sensor could be modified to increase the temperature uniformity and to decrease the electric power consumption by optimizing the layout of micro hotplate and electrodes.

Electropolymerization Mechanism for Poly(o-phenylenediamine) (PPD) and Its Electrocatalytic Behavior for $O_2$ Reduction

  • Jang, Dong Hun;Yu, Yong Seop;O, Seung Mo
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.392-397
    • /
    • 1995
  • o-Phenylenediamine (o-PD) was electropolymerized on glassy carbon electrodes under a potential cycling condition. The resulting polymer films mediated electrons for the reduction of molecular oxygen at pH=1.0. It was found from the RDE, RRDE, and cyclic voltammetry experiments that the modified electrodes reduce oxygen to hydrogen peroxide at about 300 mV lower potential than the bare glassy carbon electrode. The polymer film consisted of more than two components. Among those, only one component was active in oxygen reduction, which was formed mainly in the earlier stage of the electropolymerization. 2,3-Diaminophenazine, a cyclic dimer of o-PD, was also active in the oxygen reduction reaction, from which it was suggested that the active polymeric component has a structural unit similar to the cyclic dimer. Finally, the electropolymerization mechanism for the formation of the active and inactive components has been proposed.

A new nano-composite carbon ink for disposable dopamine biosensors (나노컴포지트 카본 잉크가 전착된 일회용 도파민 바이오센서)

  • Dinakaran, T.;Chang, S.-C.
    • Analytical Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • A new nano-composite carbon ink for the development of disposable dopamine (DA) biosensors based on screen-printed carbon electrodes (SPCEs) is introduced. The method developed uses SPCEs coupled with a tyrosinase modified nano-composite carbon ink. The ink was prepared by an “in-house” procedure with reduced graphene oxide (rGO), Pt nanoparticles (PtNP), and carbon materials such as carbon black and graphite. The rGO-PtNP carbon composite ink was used to print the working electrodes of the SPCEs and the reference counter electrodes were printed by using a commercial Ag/AgCl ink. After the construction of nano-composite SPCEs, tyrosinase was immobilized onto the working electrodes by using a biocompatible matrix, chitosan. The composite of nano-materials was characterized by X-ray photoelectron spectroscopy (XPS) and the performance characteristics of the sensors were evaluated by using voltammetric and amperometric techniques. The cyclic voltammetry results indicated that the sensors prepared with the rGO-PtNP-carbon composite ink revealed a significant improvement in electro-catalytic activity to DA compared with the results obtained from bare or only PtNP embedded carbon inks. Optimum experimental parameters such as pH and operating potential were evaluated and calibration curves for dopamine were constructed with the results obtained from a series of amperometric detections at −0.1 V vs. Ag/AgCl. The limit of detection was found to be 14 nM in a linear range of 10 nM to 100 µM of DA, and the sensor’s sensitivity was calculated to be 0.4 µAµM−1cm−2.

Preparation and Characteristics of Fluorinated Carbon Nanotube Applied Capacitive Desalination Electrode with Low Energy Consumption (불소화 탄소나노튜브를 적용한 저에너지 소모형 축전식 탈염전극의 제조 및 특성)

  • Yoo, Hyun-woo;Kang, Ji-hyun;Park, Nam-soo;Kim, Tae-il;Kim, Min-Il;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.27 no.4
    • /
    • pp.386-390
    • /
    • 2016
  • The surface of carbon nanotubes (CNTs) was modified by fluorination and applied to conductive materials to improve the energy efficiency of a capacitive desalination (CDI) electrode. CNTs were fluorinated at room temperature with a mixed gas of fluorine and nitrogen, and activated carbon based CDI electrodes were then prepared by adding 0-0.5 wt% of untreated CNTs or fluorinated CNTs with respect to the activated carbon. Fluorinated CNTs showed improved dispersibility in the electrode and also slurry as compared to untreated CNTs, which was confirmed by the zeta potential and scanning electron microscopy. Fluorinated CNTs added electrodes showed higher desalination efficiency but lower energy consumption than those of using untreated CNTs added electrodes. This was attributed to the decrease in the resistance of CDI electrodes due to the improved dispersibility of CNTs by fluorination.

Electrochemical Reduction of Thionyl Chloride by Tetradentate Schiff Base Transition Metal(II) Complexes : Catalytic Effects (네자리 Schiff Base 전이금속(II) 착물들에 의한 SOCl$_2$의 전기화학적 환원 : 촉매 효과)

  • Woo-Seong Kim;Yong-Kook Choi;Chan-Young Kim;Ki-Hyung Chjo;Jong-Soon Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.702-710
    • /
    • 1993
  • Electrochemical reduction of thionyl chloride has been carried out at glassy carbon and molybdenum electrodes, the surface of which is modified by binuclear tetradentate schiff base Co(II), Ni(II),Cu(II) and Fe(II) complexes. The catalyst molecules of transition metal(II) complexes were adsorbed on the electrode surface and reduced thionyl chloride resulting in a generation of oxidized catalyst molecules. There was an optimum concentration for each catalyst compound. The catalytic effects of SOCl$_2$ reduction were larger on glassy carbon electrodes compared to molybdenum electrodes and enhancements in reduction current of up to 120${\%}$ at the glassy carbon electrodes. The reduction currents of thionyl chloride were increased and the reduction potentials were shifted to the negative potential when scan rates became faster. The reduction of thionyl chloride was proceed to diffusion controlled reaction.

  • PDF