• Title/Summary/Keyword: modified electrode tip

Search Result 10, Processing Time 0.03 seconds

A Study on the Resistance Spot Weldability of 590 MPa Grade DP Steel with Modified Electrode Tip (가공 전극을 적용한 590 MPa급 DP강의 저항 점용접에 관한 연구)

  • Lee, Sang-Min;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.1
    • /
    • pp.71-76
    • /
    • 2010
  • The use of advanced high-strength steels (AHSS) in automotive applications has steadily increased over the past few years. Two different failure modes are generally observed in shear-tension tests for resistance spot welds of AHSS. interfacial fractures and full button pullout. Despite high load-carrying capacity. the resistance spot welds in AHSS cue prone to interfacial fractures. To improve the load carrying ability of welds during shear-lap and cross tension tests. the tip surface of the electrode was grooved in a round shape. The electrode tip surface was modified so as to concentrate the current now in the central and circumferential portion of the electrode force. The results showed that the interfacial fracture was suppressed in welds using the modified electrode. In a comparison of failure mode during mechanical tests. the welds made with the modified electrode showed a higher tendency to fail via full button pullout fracture.

Permanent Transvenous Endocardial Pacemaker Inevitably Implanted Two Electrode Leads (두개의 전극도자를 사용하게 된 Permanent Transvenous Pacemaker Implantation: 1례 보고)

  • Kwack, Moon-Sub;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.168-174
    • /
    • 1981
  • Since cardiac pacemaker was first totally implanted by Chardack, Gage and Greatbatch [1966], the electrical circuity of the cardiac pacemaker has been improved, modified, and refined. The problem of transvenous electrodes, however, is still remained; this may be due to electrode displacement, exit and/or entrance block, lead fracture and insulation defects. In permanent cardiac pacing, Irreversible loss of function of the transvenous electrode catheter eventually requires insertion of new lead. Authors now report one case that disclosed easy displacement of electrode tip in early phase of implantation and then two years and five months later, malfunctioning electrode could not be withdrawn from the cardiovascular system because it has become firmly enclosed by fibrous tissue along its course from the vein tract to the right ventricle. Under such circumstances, the electrode catheter tip was left in tricuspid annulus after being sutured at its entrance and burying the loop of lead in generator pocket. New other one electrode was then reimplantation through left external jugular vein.

  • PDF

An Experiment about Assembling Condition of Carbon Nanotube Tip for AFM (주사탐침현미경용 카본나노튜브 팁의 조립 조건 실험)

  • 박준기;한창수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.501-504
    • /
    • 2004
  • This paper describes the fabrication method for atomic force microscopy(AFM) tip with multi-walled carbon nanotube(MWNT). For making a carbon nanotube (CNT) modified tips, AC electric field which cause the dielectrophoresis was used for alignment and deposition of CNTs in this research. By dropping the MWNT solution and applying an electric field between an AFM tip and an electrode, MWNTs which were dispersed into a diluted solution were directly assembled onto the apex of the AFM tips due to the attraction by the dielectrophoretic force. In this case, we investigate the effect of the angle between a tip axis and an electrode. Experimental setup were presented, and then CNT attached AFM tips are successfully shown in this paper.

  • PDF

Experimental study of assembly of the carbon nanotube tip for SPM (SPM 용 카본 나노튜브 팁 조립의 실험적 연구)

  • Park J.K.;Kim J.E.;Han C.S.;Park Y.G.;Hwang K.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1228-1231
    • /
    • 2005
  • This paper reports about the development of scanning probe microscopy (SPM) tip with multi-walled carbon nanotube (MWNT). For making a carbon nanotube (CNT) modified tips, AC electric field which causes the dielectrophoresis was used for alignment and deposition of CNTs to the metal coated SPM tip. By dropping the MWNT solution and applying an electric field between an SPM tip and an electrode, MWNTs which were dispersed into a diluted solution were directly assembled onto the apex of the SPM tips due to the attraction by the dielectrophoretic force. In this paper, we investigate experimental conditions about the alignment of the CNT to tip axis according to the change of the angle between a tip and an electrode. Experimental results are presented, and then fabricated CNT tips are showed and measurement results for 15nm gold particles are compared with that of the conventional silicon tip.

  • PDF

Decrease of Gate Leakage Current by Employing Al Sacrificial Layer Deposited on a Tilted and Rotated Substrate in the DLC-coated Si-tip FEA Fabrication (DLC-coated Si-tip FEA 제조에 있어서 기판 상에 경사-회전 증착된 Al 희생층을 이용한 Gate누설 전류의 감소)

  • 주병권;김영조
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.27-29
    • /
    • 2000
  • For the DLC-coaled Si-tip FEA, the modified lift off-process, by which DLC coated on both gate electrode surface and gate insulator in the gate aperture could be removed, was proposed. In the process, the Al sacrificial layer was deposited on a tilted and rotated substrate by an e-beam evaporation, and DLC film was coated on the substrate by PA-CVD method. Afterward the DLC was perfectly removed except the DLC films coated on emitter tips by etch-out of Al sacrificial layer. Current-voltage curves and current fluctuation of the DLC-coated Si-tip FEA showed that the proposed lift-off process played an important role in decreasing gate leakage current and stabilizing omission current.

  • PDF

Dynamic behavior of GMA considering metal transfer (금속이행을 고려한 GMA 용접 시스템의 동특성 해석)

  • 박세홍;김면희;강세령;최상균;이상룡
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.565-568
    • /
    • 2002
  • Welding variables and conditions in gas metal arc welding (GMAW) effect on the weld quality and productivity, extensive research efforts have been made to analyze the welding variables and conditions. In this study dynamic behavior of GMAW system is investigated using the characteristic equations of the power supply, wire and welding arc. Characteristic equation of wire is modified to include the effect of droplets attached at the electrode tip. The dynamic characteristics of arc length, current, voltage with respect to the step, ramp inputs of CTWD was simulated, seam tracking procedure using arc sensor was simulated with variable V-Groove geometries and weaving frequencies. From results of simulation, some predictions about dynamic characteristics of GMAW and welding process are available. The proposed simulator and results appear to be utilized to determine the proper welding conditions, to be improved by considering power supply dynamic characteristics.

  • PDF

A Study on Dynamic Characteristics of Welding Current and Arc Length At GMAW (GMA용접에서 용접전류와 아크 길이의 동특성에 관한 연구)

  • Lee, Tae-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Welding variables and conditions in gas metal arc welding (GMAW) effect on the quality and productivity of the weld, extensive research efforts have been made to analyze the effect of the welding variables and conditions. In this study dynamic behavior of GMAW system is investigated using the characteristics of the power supply, wire and welding arc. Characteristic equation of wire is modified to include the effect of droplets attached at the electrode tip. The dynamic characteristics of arc length, current, voltage with respect to the step, ramp inputs of CTWD was simulated. From results of simulation, some predictions about dynamic characteristics of GMAW and welding process are available. The proposed simulator and results appear to be utilized to determine the proper welding conditions, to be improved by considering power supply dynamic characteristics.

A Study on Dynamic Characteristics of Welding voltage and Welding Current At GMAW (GMA 용접에서 전압과 전류의 동특성에 관한 연구)

  • Kim, Myun-Hee;Choi, Young-Geun;Lee, Moon-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.2
    • /
    • pp.207-213
    • /
    • 2001
  • Welding variables and condition in gas metal arc welding (GMAW) effect on the weld quality and productivity, extensive research efforts have been made to analyze the welding variables and conditions. In this study dynamic behavior of GMAW system is investigated using the chararcteristic equations of the power supply. wire and welding arc. Characteristic equation of wire is modified to include the effect of droplets attached at the electrode tip. The dynamic characteristics of arc length, current, voltage with respect to the step, ramp inputs of CTWD was simulated. From results of simulation, some predictions about dynamic characteristics of GMAW and welding process are available. The proposed simulator and results appear to be utilized to determine the proper welding conditions, to be improved by considering power supply dynamic characteristics.

  • PDF

저항용접 시뮬레이션을 이용한 가공전극 적용 용접 특성 평가

  • Lee, Sang-Min;Choi, Du-Youl;Park, Yeong-Do
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.97-97
    • /
    • 2010
  • 최근 자동차에서 경량화의 방안으로써 높은 강성을 요구하는 고장력강 사용이 증대 되고 있다. 그러나 고장력강은 저항 점용접 시 일반 강에 비해 높은 전류를 요구하며 계면파단 및 expulsion 발생이 용이하기 때문에 가용 전류 구간이 좁은 특성을 가진다. 많은 연구자들이 hold time, tempering 등의 process를 이용하여 고장력강의 저항 점용접성을 개선하고자 하였으나 생산 공정라인에 적용하기는 어려운 실정이다. 본 연구에서는 용접 공정 변수의 변화에 따른 용접성과 전극 형상 변화을 통한 고장력강 점 용접성 향상에 대한 연구를 실시 하였다. 고장력강의 점 용접성 비교하기 위해 표준 전극(S1)과 인위적으로 가공한 전극(M1)을 사용하였으며, 실험에 사용된 판재는 두께 1.4mm의 DP590이며, 그 결과 표준전극(S1) 보다 가공 전극(M1)의 가용 전류 구간이 0.5kA 정도 넓은 것으로 확인 되었다. 두 전극을 사용한 점용접 시험편들의 인장전단강도를 비교 해보면 표준전극(S1)을 적용한 점용접 시 인장전단강도는 KS B 0850 기준에 만족하나 계면 파단이 발생 하였다. 가공 전극(M1)을 적용한 점용접 시 인장전단강도는 규격 기준에 만족하나 버튼 파단이 발생 하였다. 두 전극을 적용한 점용접부 형상 및 용접부 온도 분포에대해 저항점용접 시뮬레이션 프로그램(SORPAS)을 이용하여 실험 결과 값과 비교 분석하였고 파단모드의 변화에 대한 원인 분석을 도출 하였다.

  • PDF

A Comparison of Surgical Methods of Inducing Femoral Head Osteonecrosis in Rats (랫드에서 대퇴골머리 골괴사 유발 외과적 방법의 비교)

  • Kim, Jun-Soo;Park, Jin-Uk;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.240-245
    • /
    • 2010
  • Osteonecrosis of the femoral head is an idiopathic and progressive disease. It was reported that several animal models have been used for the research of osteonecrosis. However, no standardized animal model for the study of osteonecrosis has been developed to date. This study was conducted to compare the degree of osteonecrosis of three surgically induced osteonecrosis models in rats. Twenty Sprague-Dawley rats (24 weeks old, male) were divided into three experimental groups and a control group, five heads each. Three groups were surgically induced into osteonecrosis; the ligamentum teres were cut and the periosteum of the femoral neck was stripped (Group S), the steel wire was ligated to the neck of the femoral head (Group W), and the femoral neck was tied up with a wire in the same way as in the W group, and burned by attaching the electrode tip to the wire and then the wire was removed (Group B). After two weeks, rats were sacrificed and the femoral head and neck were collected. Histological findings were evaluated with H/E stains, Safranin-O and TUNEL for osteonecrotic lesions in the bones and cartilages of the femoral head. Osteonecrosis was induced successfully in all groups (Group S, W and B) in two weeks, a short period of time. Significant necrotic changes of the cartilage were detected only in Group B. In the modified cautery model in particular, the method of removing the wire after cautery was completed in the experimental model of osteonecrosis more efficiently than any other method.