• Title/Summary/Keyword: model plant

Search Result 4,014, Processing Time 0.032 seconds

A Study of Thermal Power Plant Feedwater System with Modeling and L.Q.Controller (화력발전소 보일러 급수제어 계통의 모델링과 L.Q. 제어기 적용에 관한 연구)

  • 서진헌;황재호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.12
    • /
    • pp.1281-1287
    • /
    • 1990
  • A new thermal power plant feed-water system model, which is based on Astrom, is presented. Astrom's model has some difficulties in applying to practical systems because it is not able to measure the heat and energy transfer loss. Hence, in order to make up for these difficulties, the Gas State Equation is added to the model. Computer simulations are performed to show the validity of the new model at thermal power plant with practical boiler operating data and to verify the L.Q. controller effect on boiler drum level system.

The multi-objective planning for minimizing tardiness and maximizing resource utilization in a multi-plant supply chain (다중플랜트 생산 공급망 계획에서 납기지연 최소화 및 자원이용 최대화를 위한 다목적 계획)

  • 한만형;문치웅;김종수
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2001.10a
    • /
    • pp.269-272
    • /
    • 2001
  • In this paper, we presents a systematic methodology for minimizing tardiness and maximizing resource utilization in a multi-plant supply chain. A methodology is represented to a multi-objective mathematical program model. The model offers flexible and efficient multi-plant planning and scheduling. Also, We develope a realistic and flexible planning model using the genetic algorithm to solve the model.

  • PDF

Robust Adaptive Control for the System with Unmodelled Dynamics (비모형화 특성을 갖는 시스템의 견고성 적응제어)

  • 김성덕;양해원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.9
    • /
    • pp.670-677
    • /
    • 1987
  • The robustness and stability properties for a model reference adaptive control system with plant uncertainty are considered in this paper, using input-output stability theory. An error model for a typical adaptive control structure is extended to unmodelled dynamics in the plant model and then, the strictly positive real condition for global stability is examined. In general, since this condition can be easily violated due to unmodelled dynamics, a modified compensator which can be guaranteed Hev e SPR is introduced in the plant model and the effectiveness for the given structure is also given.

  • PDF

Modeling of a Small Group Scale TMR Plant for Beef Cattle and Dairy Farm in Korea(I) - Development of TMR Plant Model - (한우 및 낙농 단지용 소형 TMR 플랜트 모델 개발(I))

  • Ha, Yu-Shin;Hong, Dong-Hyuck;Park, Kyung-Kyoo
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.342-350
    • /
    • 2009
  • Currently TMR feed produced in commercial plant is one of the major source to feed cattle for both beef and dairy farm. However, because of lack of cutting and mixing system for utilizing domestic produced firmly baled round roughage in commercial TMR plant, these commercial TMR feed can not satisfy to farmers both in quality and price points of view. In order to solve these problems, a farm group size TMR plant model was developed in this study. The model plant was consist of round bale receiving and cutting system, pneumatic conveying system for transfer the roughage which was cut at the cutter to TMR mixer through pneumatic conveyor, TMR mixer enable to soften the stiff rice strew and to mix with other ingredients, finished feed bin which can be transfer to either packing system or individual farm, packing system by tycon bag which contains 400 kg unit and bulk unloading system to individual farmer. Also, a simulation model ARENA was applied to the model system in order to evaluate and check the production rate in each unit process and operation rate of total system and to find out if there are any clogged unit system obstructing the smooth flow of the total process flow. Processing cycle for produce one batch of the model plant was less than 30 minutes. Thus, it will take less than four hours for producing 16 tons per day equivalent to 1,000 beef cattle's daily feed.

A Standard Way of Constructing a Data Warehouse based on a Neutral Model for Sharing Product Dat of Nuclear Power Plants (원자력 발전소 제품 데이터의 공유를 위한 중립 모델 기반의 데이터 웨어하우스의 구축)

  • Mun, D.H.;Cheon, S.U.;Choi, Y.J.;Han, S.H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.1
    • /
    • pp.74-85
    • /
    • 2007
  • During the lifecycle of a nuclear power plant many organizations are involved in KOREA. Korea Plant Engineering Co. (KOPEC) participates in the design stage, Korea Hydraulic and Nuclear Power (KHNP) operates and manages all nuclear power plants in KOREA, Dusan Heavy Industries manufactures the main equipment, and a construction company constructs the plant. Even though each organization has a digital data management system inside and obtains a certain level of automation, data sharing among organizations is poor. KHNP gets drawing and technical specifications from KOPEC in the form of paper. It results in manual re-work of definition and there are potential errors in the process. A data warehouse based on a neutral model has been constructed in order to make an information bridge between design and O&M phases. GPM(generic product model), a data model from Hitachi, Japan is addressed and extended in this study. GPM has a similar architecture with ISO 15926 "life cycle data for process plant". The extension is oriented to nuclear power plants. This paper introduces some of implementation results: 1) 2D piping and instrument diagram (P&ID) and 3D CAD model exchanges and their visualization; 2) Interface between GPM-based data warehouse and KHNP ERP system.

Risk Monitor Development for On-Line Maintenance (가동중 정비를 위한 Risk Monitor 개발)

  • 김길유;한상훈;김태운
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.21-26
    • /
    • 1997
  • Korea Atomic Energy Research Institute (KAERI) developed a risk monitor called Risk Monster which supports for plant operators and maintenance schedulers to monitor plant risk and to avoid high peak risk by rearranging maintenance work schedule. Risk Monster can update the plant risk continuously according to the change of system/component configuration since Risk Monster reevaluates the plant risk based on the Probabilistic Safety Assessment (PSA) results. A brief description of Risk Monster is provided. The PSA model of UCN 3, 4 nuclear power plant was converted by KAERI to Risk Monster model. Using this Risk Monster model, a feasibility study of the on-line maintenance of an Essential Service Water (ESW) pump was performed. On-line maintenance of one ESW pump has been shown to be acceptably safe, and has economic benefits. In addition, it is not a violation of technical specification to continue plant operation with an out-of-service ESW pump.

  • PDF

Determining the Warming Effect Induced by Photovoltaic Power Plants in neighboring Region Using an Analytical Model (해석학적 모델을 이용한 태양광 발전소 주변 지역의 기온 상승 추정 연구)

  • Kim, Hae-Dong;Huh, Kyong-Chun;Kim, Ji-Hye
    • Journal of Environmental Science International
    • /
    • v.27 no.3
    • /
    • pp.227-231
    • /
    • 2018
  • We studied the warming effect induced by Photovoltaic(PV) power plants in rural areas during summer daytime using a simple analytical urban meteorological model. This analysis was based on observed meteorological elements and the capacity of the PV power plant was 10 MWp. The major axis length of the PV power plant was assumed to be 1km. Data of the necessary meteorological elements were obtained from a special meteorological observation campaign established for a over a PV power plant. We assumed that the wind flowed along the major axis of the PV power plant(1 km). As a result, the air temperature on the downwind side of the PV power plant was estimated to invrease by about $0.47^{\circ}C$.

Application of ASM and PHOENICS for Optimal Operation of Wastewater Treatment Plant (하수처리장 운영의 최적화를 위한 ASM, PHOENICS의 적용)

  • Kim, Joon Hyun;Han, Mi-Duck;Han, Yung Han
    • Journal of Industrial Technology
    • /
    • v.20 no.A
    • /
    • pp.73-82
    • /
    • 2000
  • This study was implemented to find an optimal model for wastewater treatment processes using PHOENICS(Parabolic, hyperbolic or Elliptic Numerical Integration Code Series) and ASM(Activated Sludge Model). PHOENICS is a general software based upon the laws of physics and chemistry which govern the motion of fluids, the stresses and strains in solids, heat flow, diffusion, and chemical reaction. The wastewater flow and removal efficiency of particle in two phase system of a grit chamber in wastewater treatment plant were analyzed to inquire the predictive aspect of the operational model. ASM was developed for a biokinetic model based upon material balance in complex activated sludge systems, which can demonstrate dynamic and spatial behavior of biological treatment system. This model was applied to aeration tank and settling chamber in Choonchun city, and the modeling result shows dynamic transport in aeration tank. PHOENCS and ASM could be contributed for the optimal operation of wastewater treatment plant.

  • PDF

Model reference adaptive controller design for missiles with nonminimum-phase characteristics (비최소 위상 특성을 갖는 유도탄의 기준 모델 적응 제어기 설계)

  • 김승환;송찬호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.624-629
    • /
    • 1993
  • In this paper, a model reference adaptive control scheme is applied to the normal acceleration controller for missiles with nonminimum-phase characteristics. The proposed scheme has an auxiliary compensator, an identifier of plant parameters and a feedback control law. First, plant parameters are estimated by the identifier and based the parameter estimates the coefficients of the compensator are calculated so that the estimated plant model with the compensator becomes minimum-phase. In this calculation, Nehari Algorithm is used. Parameters of the control law are then updated so that the extended plant model follows the given reference model. It is shown that the performance of the designed controller is satisfied via computer simulations.

  • PDF