• 제목/요약/키워드: mode volume

검색결과 599건 처리시간 0.026초

단류식 창조발전의 조력발전소 최적화 운영 Model 개발에 관한 연구 (A Study on Developement of Optimization Model for Single Action Tidal Power Station)

  • 김현한;김만기;김준규;옥연호;김광호;정종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1144_1145
    • /
    • 2009
  • Tidal power station is using the difference of the ebb and flow and the single action tidal power is dependent on tide amplitude and basin volume. Therefore the inflow of basin in rainy season has also effect on the daily power. Also if operating units are changed then starting head too changed. Therefore the number of units are very important for the optimization model. According to our study the primary point when we make a determination of optimization is starting head and governorl control mode. On this study optimization model for tidal power station is considered all of this conditions.

  • PDF

글로벌 해운회사의 공컨테이너 재배치 최적화 (Optimizing Empty Container Repositioning at a Global Maritime Company)

  • 최성훈;김화중;김광태
    • 산업공학
    • /
    • 제24권2호
    • /
    • pp.164-172
    • /
    • 2011
  • H maritime company in Korea had a long history of difficulty in obtaining enough empty containers to transport its commodities. Despite efforts to resolve the problem, the repositioning of empty containers between depots was still planned manually, which consumed much worker time. To automate the generation of reposition plans, we developed a planning system to optimize the company's reposition of empty containers between global depots with a linear programming model functioning as a key decision engine in the system. The model determines the route, volume and mode of transportation for repositioning empty containers from depots with surplus containers to those requiring containers, as well as the empty space of ships generated from the unloading or loading of full and empty containers. The system has been in operation in the company's global network since March 2008.

유체로 연성된 두 사각평판의 고유진동수 (Natural Frequency of Two Rectangular Plates Coupled with Fluid)

  • 정경훈;박근배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.908-913
    • /
    • 2002
  • An analytical study is presented on the hydroelastic vibration of two rectangular identical plates coupled with a bounded fluid by using the finite Fourier series expansion method. It is observed that the two contrastive modes, the so called the out-of-phase and in-phase modes appear. The proposed analytical method is verified by observing a good agreement to three dimensional finite element analysis results. All natural frequency of the in-phase modes can be predicted well by the combination of the dry beam modes. The theoretical prediction for the out-of-phase mode can be improved by using the polynomial functions satisfying the plate boundary conditions and fluid volume conservation instead of using dry beam modes.

  • PDF

An Improved Single-Phase Full-Bridge ZVS Inverter with a Subtractive Coupled Magnetics

  • Soh, Jae-Hwan;Lim, Jong-Yeop;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1835-1841
    • /
    • 2017
  • An improved single-phase full-bridge zero-voltage-switching inverter using a subtractive coupled magnetics is proposed in this paper. The proposed topology overcomes several drawbacks of the conventional ARCPI zero-voltage-switching inverter including two bulky capacitors which can cause problems such as the need for a protection circuit and voltage fluctuation of split capacitors. Also the proposed topology can reduce the number of devices required for ZVS through a simplified auxiliary circuit, thus achieving low cost and small volume and is applicable a modified unipolar PWM scheme. Detail mode analysis and design considerations are provided for optimal efficiency. In the end, the effectiveness and feasibility of the proposed topology are verified experimentally under various conditions.

SFRC구조물의 휨거동에 관한 해석적 연구 (Analytical Study of Flexural Behavior on Steel Fiber Reinforced Concrete Structure)

  • 서성탁
    • 한국산업융합학회 논문집
    • /
    • 제11권1호
    • /
    • pp.35-40
    • /
    • 2008
  • Various characters of the concrete are greatly improved as the effect of the steel fiber. As the improvement effect of the steel fiber, the increment in flexural strength, shear strength, toughness, and impact strength are remarkable, and tenacious concrete is obtained. This paper presents model which can predict mechanical behavior of the structure according to aspect ratio and volume fraction of steel fiber. Experiments on compressive strength, elastic modulus and tensile strength were performed with self-made cylindrical specimens of variable aspect ratios. This paper presents an analytical study on the behavior of a beam specimen with steel fiber reinforced concrete(SFRC). The effect of the SFRC on the crack pattern, failure mode and the flexural behavior of the structure were investigated. The analysis model based on the nonlinear layered finite element method was successfully able to find the necessary amount of steel fibers, tensile steels and beam section which can best approximate flexural strength and ductility of a given conventionally reinforced concrete beam.

  • PDF

Improving buckling response of the square steel tube by using steel foam

  • Moradi, Mohammadreza;Arwade, Sanjay R.
    • Structural Engineering and Mechanics
    • /
    • 제51권6호
    • /
    • pp.1017-1036
    • /
    • 2014
  • Steel tubes have an efficient shape with large second moment of inertia relative to their light weight. One of the main problems of these members is their low buckling resistance caused from having thin walls. In this study, steel foams with high strength over weight ratio is used to fill the steel tube to beneficially modify the response of steel tubes. The linear eigenvalue and plastic collapse FE analysis is done on steel foam filled tube under pure compression and three point bending simulation. It is shown that steel foam improves the maximum strength and the ability of energy absorption of the steel tubes significantly. Different configurations with different volume of steel foam and composite behavior is investigated. It is demonstrated that there are some optimum configurations with more efficient behavior. If composite action between steel foam and steel increases, the strength of the element will improve, in a way that, the failure mode change from local buckling to yielding.

Photocatalytic Degradation of 2,4,6-Trinitrotoluene in Wastewater Using a Thin-Film TiO2 Reactor

  • Shin, Gi-Bum;Kim, Yeong-Kwan
    • Environmental Engineering Research
    • /
    • 제13권1호
    • /
    • pp.28-32
    • /
    • 2008
  • The photocatalytic treatment of water contaminated with 2,4,6-trinitrotoluene (TNT) was explored in bench-scale experiments in batch mode using a Pyrex tube coated with a thin film of $TiO_2$ located inside a photoreactor. The reactor was aerated by purging it with compressed air before initiating the photocatalytic reaction. The rate of TNT degradation approximated first-order kinetics. The reaction rate constant decreased as the TNT concentration increased from 25 to 100 mg/L, while the first-order kinetics could be modeled using a Langmuir adsorption isotherm. The addition of the organic reductants methanol and EDTA significantly enhanced the rate of TNT degradation, with optimum results in the presence of 20% methanol by volume. EDTA increased the rate of TNT removal by enhancing the role of the reductants.

공조기 덕트 내의 자연대류가 실내 유입유량에 미치는 영향 (The Effect of Flow Rate into Room by Natural Convection in Air Conditioner Duct)

  • 공태우;정한식;정효민
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.160-166
    • /
    • 2001
  • A numerical analysis has been performed for natural convection in an air conditioner duct system. The governing equations were solved a finite volume method using a SIMPLE algorithm. In the calculation mode of duct, the room temperature was preserved at $25.0^{\circ}C$ and duct wall temperature had a temperature of 15, 20.0, 22.5, 23.75, 26.25, 27.5 30 and $35^{\circ}C$. The results of velocity vectors and contours have been represented for various parameters. Based on the numerical data, the relationships between temperature difference and flow rate into room was represented. In the case of $T_\gamma>T_\omega$, the equation for temperature difference and flow rate was $Q=0.0285\triangleT^0.4005$, and in the case of $T_\gamma>T_\omega$, the equation was $Q=0.0099\triangleT^0.4752$. The duct system has an important relation to room temperature and duct wall temperature.

  • PDF

도시 간선도로 교통류관리를 위한 교통모형의 개발 및 검증 (Development and Test of a Macro Traffic Simulation Model for Urban Traffic Management)

  • 이인원
    • 대한교통학회지
    • /
    • 제13권4호
    • /
    • pp.79-103
    • /
    • 1995
  • The elasticity of a model is considered most important. Without showing the proper elasticity any model cannot provide useful information for decision making. This paper demonstrates a macro model which can generate dynamic transport informations every 15 minutes. Without the Wardrop principles and the monotonicity assumptions for the link travel time and link volume relationship, the basic elements of this new modeling approache are composed of link density simulation, stochastic incremental route choice, departure time choice, destination choice and mode choice. The elasticity of the proposed model is examined based on elasticity equations and simulation results. Also the transferability from a mega city like Seoul to a big city like Daejon is demonstrated for the choice model. The issues centering around the dynamic relations among density(k), speed(u), and flow rate(v) are also discussed for the modeling of highly congested situations.

  • PDF

An Isolated Soft-Switching Bidirectional Buck-Boost Inverter for Fuel Cell Applications

  • Zhang, Lianghua;Yang, Xu;Chen, Wenjie;Yao, Xiaofeng
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.235-244
    • /
    • 2010
  • This paper presents a new isolated soft-switching bidirectional buck-boost inverter for fuel cell applications. The buck-boost inverter combines an isolated DC-DC converter with a conventional inverter to implement buck-boost DC-DC and DC-AC conversion. The main switches achieve zero voltage switching and zero current switching by using a novel synchronous switching SVPWM and the volume of the transformer in the forward and fly-back mode is also minimized. This inverter is suitable for wide input voltage applications due to its high efficiency under all conditions. An active clamping circuit reduces the switch's spike voltage and regenerates the energy stored in the leakage inductance of the transformer; therefore, the overall efficiency is improved. This paper presents the operating principle, a theoretical analysis and design guidelines. Simulation and experimental results have validated the characteristics of the buck-boost inverter.