• 제목/요약/키워드: mode frequency

검색결과 4,293건 처리시간 0.049초

Mode localization and frequency loci veering in an aircraft with external stores

  • Liu, J.K.;Chan, H.C.
    • Structural Engineering and Mechanics
    • /
    • 제8권2호
    • /
    • pp.181-191
    • /
    • 1999
  • This paper presents an investigation of the mode localization and frequency loci veering phenomena in an aircraft with disordered external stores. Two theoretical analyses are carried out to study the occurring mechanism of the two phenomena: condensation technique in the subspace spanned by modes of interest and geometric mapping theory in the complex plane. Two simple criteria for predicting the occurrence of the mode localization and frequency loci veering are put forward. The prediction of the phenomena by our theoretically proposed criteria is in good agreement with that obtained through numerical calculations of characteristic solutions of the disordered system.

링형 초음파모터의 모드선정에 따른 진동특성 해석 (The Vibration Characteristic Analysis by Mode Variation of Ring Type Ultrasonic Motor)

  • 윤신용;백수현;김현일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권5호
    • /
    • pp.309-317
    • /
    • 2004
  • This paper suggested the vibration characteristic improvement by variation mode of ring type ultrasonic motor. Design for the piezoelectric ceramic and elastic body of stator were calculated by the finite element method(FEM) that consider the resonance frequency, vibration mode and coupling efficiency etc. Through the result of vibration analysis from 6 order mode to 8 mode, the 7 order mode was gained very an excellent results that it was the coupling efficient, minimum power loss and bending vibration value. Here over 7 order mode, this paper was acquired that an output current for input voltage was very a large increased results. The result of vibration calculation, from thickness 0.5[mm] to 2[mm], knew the fact that the vibration displacement at 0.5[mm] is an high value too. From such result, this paper was manufactured the ultrasonic motor of outer diameter 5O[mm] , inter 22[mm] having the about 43.86[KHz] resonance frequency. We have gated that a simulation result is 42.2[KHz] and an experiment result is 43.86[KHzl The propriety of this paper was established though comparison. investigation of simulation and experiment result.

$L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교 (Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors)

  • 우상호;김동연;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

능동형 커먼 모드 전압 감쇄기를 통한 유도 전동기의 고주파 누설전류 억제 (Suppression of high frequency leakage current in PWM Inverter-Fed Induction Motor Drives using Active Common Mode Voltage Damper)

  • 홍순일
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.186-190
    • /
    • 2000
  • This paper propose a "Active common-mode voltage damper circuit" that capable of a suppression of a common-mode voltage produced in the PWM VSI. The four level half-bridge PWM inverter circuit and common-mode transformer are incorporated into the "Active common-mode voltage damper" the design method of which is presented Effect of "Active common-mode voltage damper" in this paper verifies a propriety and effectiveness in 2.2[kW] induction motor drive using IGBT inverter. Experimental results show that "common-mode voltage damper" makes contributions to reducing a high frequency leakage current and common-mode voltage.leakage current and common-mode voltage.

  • PDF

전류모드 적분기를 이용한 듀얼 모드 기저대역 필터 설계 (Design of a Dual Mode Baseband Filter Using the Current-Mode Integrator)

  • 김병욱;방준호;조성익;최석우;김동용
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.260-264
    • /
    • 2008
  • In this paper, a dual mode baseband analog channel selection filter is described which is designed for the Bluetooth and WCDMA wireless communications. Using the presented current-mode integrator, a dual mode channel selection filter is designed. To verify the current-mode integrator circuit, Hspice simulation using 1.8V Hynix $0.18{\mu}m$ standard CMOS technology was performed and achieved $50.0{\sim}4.3dB$ gain, $2.29{\sim}10.3MHz$ unity gain frequency. The described third-order dual mode analog channel selection filter is composed of the current-mode integrator, and used SFG(Signal Flow Graph) method. The simulated results show 0.51, 2.40MHz cutoff frequency which is suitable for the Bluetooth and WCDMA baseband block each.

Structural modal identification through ensemble empirical modal decomposition

  • Zhang, J.;Yan, R.Q.;Yang, C.Q.
    • Smart Structures and Systems
    • /
    • 제11권1호
    • /
    • pp.123-134
    • /
    • 2013
  • Identifying structural modal parameters, especially those modes within high frequency range, from ambient data is still a challenging problem due to various kinds of uncertainty involved in vibration measurements. A procedure applying an ensemble empirical mode decomposition (EEMD) method is proposed for accurate and robust structural modal identification. In the proposed method, the EEMD process is first implemented to decompose the original ambient data to a set of intrinsic mode functions (IMFs), which are zero-mean time series with energy in narrow frequency bands. Subsequently, a Sub-PolyMAX method is performed in narrow frequency bands by using IMFs as primary data for structural modal identification. The merit of the proposed method is that it performs structural identification in narrow frequency bands (take IMFs as primary data), unlike the traditional method in the whole frequency space (take original measurements as primary data), thus it produces more accurate identification results. A numerical example and a multiple-span continuous steel bridge have been investigated to verify the effectiveness of the proposed method.

Enhanced least square complex frequency method for operational modal analysis of noisy data

  • Akrami, V.;Zamani, S. Majid
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.263-273
    • /
    • 2018
  • Operational modal analysis is being widely used in aerospace, mechanical and civil engineering. Common research fields include optimal design and rehabilitation under dynamic loads, structural health monitoring, modification and control of dynamic response and analytical model updating. In many practical cases, influence of noise contamination in the recorded data makes it difficult to identify the modal parameters accurately. In this paper, an improved frequency domain method called Enhanced Least Square Complex Frequency (eLSCF) is developed to extract modal parameters from noisy recorded data. The proposed method makes the use of pre-defined approximate mode shape vectors to refine the cross-power spectral density matrix and extract fundamental frequency for the mode of interest. The efficiency of the proposed method is illustrated using an example five story shear frame loaded by random excitation and different noise signals.

Optimal Compensation of Dual Carrier Frequency Offsets for MISO-mode DVB-T2

  • Jeon, Eun-Sung;Seo, Jeong-Wook;Yang, Jang-Hoon;Paik, Jong-Ho;Kim, Dong-Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권2호
    • /
    • pp.610-628
    • /
    • 2012
  • Dual carrier frequency offsets (CFOs) occur in multiple-input single-output (MISO)-mode DVB-T2 systems, where signals are transmitted simultaneously from two distributed transmitters in a single frequency network (SFN). In this paper, we first derive an optimal compensation frequency for dual CFOs. We also propose an algorithm that optimizes the compensation frequency for the MISO-mode DVB-T2 application. Its performance is compared with the conventional scheme by using a full DVB-T2 simulator.

채터로브 계산을 위한 고유모우드 분석법 (Natural Mode Analysis for Chatter Lobe Estimation)

  • 윤문철;조현덕;이응숙
    • 한국기계가공학회지
    • /
    • 제2권2호
    • /
    • pp.60-66
    • /
    • 2003
  • For the estimation of chatter lobe boundary it is very important to calculate the natural mode of cutting process. There are many time series algorithms for getting the natural mode of structural endmilling dynamics considering the cutting process. In this study, we have compared several time series methods such as AR algorithm, ARX, ARMAX, ARMA, Box Jenkins, Output Error, Recursive ARX, Recursive ARMAX considering the sampling frequency. As a results, the ARX, ARMAX and IV 4 are more desirable algorithms for the calculation of modal parameters such as natural frequency and damping ratio In endmilling operation. Also these algorithms may be adopted for the natural mode estimation of endmilling operation for chatter lobe prediction.

  • PDF

Improvement of aeroelastic stability of hingeless helicopter rotor blade by passive piezoelectric damping

  • Yun, Chul-Yong;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제7권1호
    • /
    • pp.54-64
    • /
    • 2006
  • To augment weakly damped lag mode stability of a hingeless helicopter rotor blade in hover, piezoelectric shunt with a resistor and an inductor circuits for passive damping has been studied. A shunted piezoceramics bonded to a flexure of rotor blade converts mechanical strain energy to electrical charge energy which is dissipated through the resistor in the R-L series shunt circuit. Because the fundamental lag mode frequency of a soft-in-plane hingeless helicopter rotor blade is generally about 0.7/rev, the design frequency of the blade system with flexure sets to be so. Experimentally, the measured lag mode frequency is 0.7227/rev under the short circuit condition. Therefore the suppression mode of this passive damping vibration absorber is adjusted to 0.7227/rev. As a result of damping enhancement using passive control, the passive damper which consists of a piezoelectric material and shunt circuits has a stabilizing effect on inherently weakly damped lag mode of the rotor blades, at the optimum tuning and resistor condition.