• 제목/요약/키워드: mobility gap

검색결과 254건 처리시간 0.023초

Mobility-Spectrum Analysis of an Anisotropic Material System with a Single-Valley Indirect-Band-Gap Semiconductor Quantum-Well

  • Joung, Hodoug;Ahn, Il-Ho;Yang, Woochul;Kim, Deuk Young
    • Electronic Materials Letters
    • /
    • 제14권6호
    • /
    • pp.774-783
    • /
    • 2018
  • Full maximum-entropy mobility-spectrum analysis (FMEMSA) is the best algorithm among mobility spectrum analyses by which we can obtain a set of partial-conductivities associated with mobility values (mobility spectrum) by analyzing magnetic-field-dependent conductivity-tensors. However, it is restricted to a direct band-gap semiconductor and should be modified for materials with other band structures. We developed the modified version of FMEMSA which is appropriate for a material with a single anisotropic valley, or an indirect-band-gap semiconductor quantum-well with a single non-degenerate conduction-band valley e.g., (110)-oriented AlAs quantum wells with a single anisotropic valley. To demonstrate the reliability of the modified version, we applied it to several sets of synthetic measurement datasets. The results demonstrated that, unlike existing FMEMSA, the modified version could produce accurate mobility spectra of materials with a single anisotropic valley.

이동도갭 상태들의 수소화된 비결정 실리콘 전계효과 트랜지스터 성능에 대한 영향 (Effects of Mobility-Gap States on the Performance of a-Si:H Field-Effect Transistors)

  • 제갈장
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.52-57
    • /
    • 1995
  • An accurate and efficient single-integral semi-numerical model is developed and applied to analyse effects of localized electronic states in the mobility gap on the drain-current versus gale-voltage characteristics of hydrogenated amorphous field-effect transistors. It is shown that the low-density deep-gap states distributed in the midgap also sensitively and largely influence the device electronic performance as well as well as the large-density tail states distributed near the conduction band edge.

  • PDF

GZO 박막에 대한 비정질 구조에 따른 산소공공과 전하농도의 연관성에 대한 연구 (A Study on the Relationship between Oxygen and Carrier Concentration in a GZO Film on an Amorphous Structure)

  • 김도형;김홍배
    • 반도체디스플레이기술학회지
    • /
    • 제14권4호
    • /
    • pp.25-29
    • /
    • 2015
  • In this study, RF magnetron sputtering was used to investigate the relationship between oxygen vacancy and carrier concentration in a GZO film on an amorphous structure. RF power was fixed at 50W and Ar flow was changed on a glass plate to create a thin film at room temperature. The transmittance of Al-adopted amorphous GZO was measured at 85% or higher; therefore, the transmittance was shown to be outstanding in all films. The hall mobility was also shown to be higher at the film showing the high transmittance at a short-wavelength, whereas the optical energy gap was shown to be higher at the film with high oxygen vacancy. The oxygen vacancy at the amorphous oxide semi-conductor increased the optical energy gap while it was not directly involved in increasing the mobility. The oxygen vacancy increases the carrier concentration while lowering the quality of amorphous structure; such factor, therefore affected the mobility. The increase of amorphous property is a direct way to increase the mobility of amorphous oxide semi-conductor.

슬랙스 동작 적합성 평가의 정량적 평가 기준 설정 (Establishing Quantitative Evaluation Standards for the Mobility test of Slacks)

  • 김선영;남윤자
    • 한국의류산업학회지
    • /
    • 제18권1호
    • /
    • pp.80-90
    • /
    • 2016
  • This study presents quantitative evaluation standards for they mobility test, conducted in the process of a slacks fit test. This study quantified the subjects' evaluation on the wearability of slacks to provide objective qualitative evaluation methods for existing mobility tests. The subjects were women of standard bodytype between the ages of 18 and 24 wearing slacks designed to test their mobility based on differences in ease in waist girth, hip girth, crotch length and knee length. A qualitative evaluation tested the wearability of slacks. Clothing pressure and gap area between the body and slacks were measured based on a quantitative evaluation. The clothing pressure and the gap area between the body and slacks (which reflect the results of the wearability test) were presented in this study as quantitative evaluation standards. Clothing pressure tended to increase as the ease of slacks decreased; however, clothing pressure standards, that induce discomfort, differed by body parts. The hip, crotch, and knee area were relatively less sensitive despite the waist and the abdominal area sensitivity to clothing pressure. This study suggests the minimum ease for the appropriate wearing comfort of slacks by region and motion as standards for the quantitative evaluation of mobility tests. These was reset in accordance to the limits of clothing pressure when the minimum ease was considered as wearable but exceeded the clothing pressure limits.

Development of the Accessibility Guidelines for Mobility Handicapped Persons in Passenger Ship

  • Kim, Hongtae;Lee, Jong-Gap
    • 한국항해항만학회지
    • /
    • 제36권9호
    • /
    • pp.763-767
    • /
    • 2012
  • The ratio of the mobility handicapped person is about 25.8% of the total population in Korea(MCT, 2006). In order to prepare for the enforcement of the "Transportation Services Improvement Act for the Mobility Handicapped People"(MCT, 2006), various equipments and installations should be developed to ensure appropriate safety level for the mobility handicapped persons in maritime transportation. While approximately 10 million people are using domestic passenger vessels annually, preferences for maritime transport is very low, especially for the mobility handicapped. This study reviewed a current status of the mobility handicapped person in domestic passenger ship and analysed the improvement plan for them. To investigate the current status of domestic passenger vessel usage by the mobility handicapped, to analysis the requirements for amenities necessary for the mobility handicapped and select the ones to be developed based on the investigated results and to do feasibility study of barrier-free ship.

New Graphene Electronic Device Structure for High Ion/Ioff Ratio

  • 정현종
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.112-112
    • /
    • 2012
  • Graphene has been considered as one of the potential post Si-materials due to its high mobility. [1] However, since graphene is semi-conductor with zero band gap, it is difficult to achieve high Ion/Ioff ratio, one of the most important requirements for commercial devices. There have been many attempts to open its band gap for high Ion/Ioff ratio, but most of them end up lowering the mobility. [2-5] Thus, we proposed and demonstrated a new device structure for graphene transistor based on one of the unique properties of graphene for high Ion/Ioff: using this approach, we were able to achieve the ratio over $10^5$. [6] Our device has several major advantages over previously proposed graphene based electronic devices. Since our device does not alter the given properties of graphene, such as opening the band gap, it has no fundamental issues on mobility degradations. In addition, our device is fully compatible with current Si technology and we were able to fabricate the devices with 6 inch wafer scale with CVD (Chemical Vapor Deposition) grown graphene. In this presentation, we will discuss about the details of our graphene device including the device structure and the detailed understanding of working mechanism. We will present device characteristics including I-V curves with $10^5$ on/off ratio. We will also present the performance of an inverter based on our devices. Finally, we will discuss the current issues and their potential solutions.

  • PDF

철도 운영의 계층 간 형평성 향상 가치 산정방안 연구 (A Methodology for Estimating the Value of Interclass Equity Improvement by Railway Operations)

  • 장수은;정규화;김성수
    • 대한교통학회지
    • /
    • 제25권6호
    • /
    • pp.121-128
    • /
    • 2007
  • 본 연구에서는 철도 운영에 따른 계층 간 형평성 향상 가치 산정방안을 제시한다. 이를 위하여 교통부문의 계층간 형평성을 사회집단 간 이동성 격차의 측면에서 살펴보고, 철도 운영에 따른 이동성 격차 완화의 사회적 가치를 형평성의 향상으로 해석한다. 특히 철도 서비스 등급별 형평성 향상 가치 원단위를 공익목적 요금감면액 규모로 정량화하며, 요금감면에 탄력적/비탄력적 수요의 소비자 잉여 산정방안의 차이점을 논의한다. 본 연구의 결과가 보다 신중한 철도사업 타당성 평가수행에 일조할 수 있기를 기대한다.

Bi-Te계 열전소재 성능 증대를 위한 Weighted Mobility Ratio 제어 (Control of Weighted Mobility Ratio to Enhance the Performance of Bi-Te-based Thermoelectric Materials)

  • 김민영;김현식;이규형
    • 마이크로전자및패키징학회지
    • /
    • 제28권4호
    • /
    • pp.103-107
    • /
    • 2021
  • 좁은 밴드갭 반도체 특성을 나타내는 열전소재의 온도에 따른 전자전도 및 열전도 특성은 다수 캐리어 뿐 아니라 소수 캐리어의 전도 거동에 의해 결정된다. 따라서 소수 캐리어의 weighted mobility에 대한 다수 캐리어의 weighted mobility의 비율로 정의되는 weighted mobility ratio는 열전소재의 성능 증대에 매우 중요한 인자이다. 본 논문에서는 열전소재의 전자전도 현상에 대한 이론적인 고찰을 바탕으로 weighted mobility ratio 제어가 열전소재의 성능에 미치는 영향을 규명하여 고성능 Bi-Te계 열전소재 개발에 효과적으로 활용할 수 있는 소재 설계 지침을 제공하고자 한다.

Stilbenquinone이 도핑된 고분자 박막의 전자 이동도 (Electron Drift Mobility in Stilbenquinone-Doped Polymer Film)

  • 조종래;정재훈;손세모;김강언;정수태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.870-873
    • /
    • 2001
  • The electron drift mobilitity of poly(4,4'-cyclohexylidenediphenyl carbonate)(PC-Z) doped with 3,5-dimethyl-3',5'-di-t-butylstilbenequinone(MBSQ) was measured by the time-of-flight technique. Energy gap of the polymer doped with 25wt% of MBSQ was 3.1 eV. The electron drift mobility was 2.98${\times}$10$\^$-6/$\textrm{cm}^2$/V$.$s at 293K. The electric field and temperature dependences of the electron drift mobility were discussed with Poole-Frenkel and Arrhenius formulations. The activation energy(E$\_$0/), Poole-Frenkel coefficient(${\beta}$) and effective temperature(T$\_$eff/) of the mobility are 0.815 eV, 1.73${\times}$10$\_$-4/ eV$.$cm$\^$1/2//V$\_$1/2/ and 6.43${\times}$10$^2$K, respectively.

  • PDF

초기 골 접촉이 없는 순수 티타늄 임프란트 주위 골의 치유반응 (Healing of the bone around pure titanium implants without primary bone contact)

  • 안재현;김흥중;박주철;한경윤;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.233-249
    • /
    • 1999
  • Primary fixation is one of the most important factor in establishing adequate osseointegration between implant and bone. To evaluate the initial healing response of bone around implants without primary bone contact, this study was designed to create considerable space between implant and bone in 5 mongrel dogs, about 1-year old. After 3 holes of 6.0mm in diameter were prepared at the femur neck of the dogs, commercially pure titanium thread type implants(STERI-$OSS^{(R)}$), 8mm in length and 3.8mm, 5.0mm and 6.0mm in diameter, were inserted. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), and the penetration of upper soft tissue into the gap was inhibited by it. The each implant was positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 were inserted in 2 dogs for mobility test and removal torque test.Fluorescent dyes were injected in order of Doxycycline, Alizarin Red S, and Calcein at intervals of 2 weeks. At 4-, 8-, and 12-week after placement, 3 dogs were sacrificed for histologic observation, and at 8- and 12-week after placement, 2 dogs were sacrificed for mobility test using $Periotest^{(R)}$ (Simens AG, Bensheim, Germany) and torque test using Autograph AGS-1000D $series^{(R)}$(Japan). The result were as follows: 1. The wider the gap between bone and implant was, the less bone maturity was, and the later osseointegration was occurred. Trabecular direction of new bone around implant was changed from parallel to perpendicular to the implant, and the gap was filled with new bone, over time. 2. There was a decreasing tendency over time in the mobility of all implants, but the wider gap between bone and implant was, the smaller decrease of the mobility was. 3. There was a increasing tendency over time in the removal torque gauge of all implants, and the wider gap was, the smaller increase of the removal torque gauge was. The results suggest that osseointegration in case of implant without primary bone contact may be obtained by guided bone regeneration technique with prolonged healing period, but the time of second surgery should be considered carefully.

  • PDF