• Title/Summary/Keyword: mm long

Search Result 2,166, Processing Time 1.461 seconds

Effect of GLUMA desensitizer on the retention of full metal crowns cemented with Rely X U200 self-adhesive cement

  • Lawaf, Shirin;Jalalian, Ezatallah;Roshan, Roshanak;Azizi, Arash
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.404-410
    • /
    • 2016
  • PURPOSE. Considering the importance of retention in the success and long-term clinical service of fixed partial dentures (FPDs) as well as the existing controversy regarding the effect of GLUMA desensitizer on the retention of full metal crowns cemented with RelyX U200 self-adhesive cement, this study aimed to assess the effect of GLUMA desensitizer on the retention of full metal crowns cemented using RelyX U200. MATERIALS AND METHODS. In this experimental study, 20 sound human premolars were prepared; a 0.5 mm chamfer finish line was prepared above the cementoenamel junction. The teeth were randomly assigned to two groups: a desensitizer group (n = 10, treated with GLUMA desensitizer) and a control (n = 10, no surface treatment). Full metal crowns were fabricated of base metal alloy and had a ring. All crowns were cemented with RelyX U200 and subjected to retention test by using a universal testing machine. The data were analyzed using SPSS version 20 and independent t-test. RESULTS. The mean tensile bond strength was significantly higher in the GLUMA desensitizer group ($230.63{\pm}63.8N$) compared to the control group ($164.45{\pm}39.3N$) ($P{\leq}.012$). CONCLUSION. GLUMA desensitizer increases the tensile bond strength of RelyX U200 self-adhesive cement to dentin.

Marginal bone level changes in association with different vertical implant positions: a 3-year retrospective study

  • Kim, Yeon-Tae;Lim, Gyu-Hyung;Lee, Jae-Hong;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • 제47권4호
    • /
    • pp.231-239
    • /
    • 2017
  • Purpose: To retrospectively evaluate the relationship between the vertical position of the implant-abutment interface and marginal bone loss over 3 years using radiological analysis. Methods: In total, 286 implant surfaces of 143 implants from 61 patients were analyzed. Panoramic radiographic images were taken immediately after implant installation and at 6, 12, and 36 months after loading. The implants were classified into 3 groups based on the vertical position of the implant-abutment interface: group A (above bone level), group B (at bone level), and group C (below bone level). The radiographs were analyzed by a single examiner. Results: Changes in marginal bone levels of $0.99{\pm}1.45$, $1.13{\pm}0.91$, and $1.76{\pm}0.78mm$ were observed at 36 months after loading in groups A, B, and C, respectively, and bone loss was significantly greater in group C than in groups A and B. Conclusions: The vertical position of the implant-abutment interface may affect marginal bone level change. Marginal bone loss was significantly greater in cases where the implantabutment interface was positioned below the marginal bone. Further long-term study is required to validate our results.

곡률과 회전을 고려한 유공 강판의 자유진동해석 (Free Vibration Analysis of Perforated Steel Plates with Various Cutout Curvatures and Rotations)

  • 우진호;나원배
    • 한국해양공학회지
    • /
    • 제24권6호
    • /
    • pp.61-70
    • /
    • 2010
  • This study presents free vibration analyses of perforates steel plates with various cutouts. Four different parameters (shape, size, curvature radius ratio, and rotation of cutouts) were considered to investigate the effects of those parameters on the free vibration characteristics, such as natural frequencies of the perforated steel plates. Three different shapes of cutouts are circle, square, and triangle, and the considered sizes are 5, 10, 15, 20, and 25 mm. For the triangular and square cutouts, the characteristic radii of the inscribed circles of those cutouts were defined. In addition, the curvature radius ratio was defined as the ratio of curvature radius of bluntness and the characteristic radius. Then, total seven different curvature radius ratios (0, 0.1, 0.3, 0.5, 0.7, 0.9, and 1) were considered. To investigate the rotation effect of the cutouts, it was considered four rotations ($0^{\circ}$, $15^{\circ}$, $30^{\circ}$, and $45^{\circ}$) for the square cutouts and three rotations (0, 15, and 30) for the triangular cutouts. All the free vibration analyses were conducted using a general purpose finite element program. From the analyses we found that the most influential parameter for the free vibration response of the perforated plates is the size of cutout. The other factors such as the shape, curvature radius ratio, and rotation are minors; they mainly change the natural frequency as long as the size effect is accompanied.

Retrospective Clinical Study on the Survival Rate and the Evaluation of Marginal Bone Resorption on SNUCONE AF+II® Implants

  • Kim, Panjun;Jung, Myungjin;Jeong, Jihye;Choi, Sungyu;Hur, Sunghwi;Lee, Seulki
    • Journal of Korean Dental Science
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2020
  • Purpose: This study analyzes the clinical results of SNUCONE AF+II® (SNUCONE Implant) implants placed in the edentulous region to determine the implant survival rate and the marginal bone healing pattern in the healing process. Materials and Methods: Two hundred forty implants placed in 131 patients with SNUCONE AF+II® implant system from January 1, 2014 to December 31, 2014 at Cheongju Hankook General Hospital were followed up for 5 years. Result: We evaluated 240 SNUCONE AF+II® implants of 131 patients from January 1, 2014 to December 31, 2014 at Cheongju Hankook General Hospital, and the results are as following: 1) Three implants were failed out of 240 implants of 131 patients and the survival rate was 98.75%. 2) The marginal bone resorption was 0.95±1.84 mm for 4 years after prosthesis placement, showing favorable result. Conclusion: Although long-term cumulative evaluations and studies should be performed in the future, SNUCONE AF+II® implants show high cumulative survival and low marginal bone resorption according to the results of this study, which believed to give outstanding result in various dental implant procedure.

STACIR/AW 송전선의 장시간 운전에 따른 기계적 물성 변화 (Changes of Mechanical Properties by a Long Term Operation in STACIR/AW Conductor)

  • 김병걸;박수동;김상수;이희웅;신구용;이동일;민병욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1258-1261
    • /
    • 2004
  • ACSR전력선의 송전용량 증가를 위해 개발된 증용량저이도 송전선인 STACBUAW(Super Thermal-resistant Aluminum alloy Conductors, aluminum-clad Invar-Reinforced)전선은 초내열 Al도체 및 인바강선의 사용으로 비교적 고온에서의 안정적 운전이 가능하다. 그러나 고온 환경에서 장시간 노출된 STACIR/AW전선의 안정적 관리를 위해서는, 열화 된 STACIR/AW 전선의 인장강도, 각 구성소재의 탄성 계수, 비틀림 계수 둥과 같은 기계적 물성이 장기 운전 모의를 위해 설정된 열화온도, 열화시간 등에 대해 종합적으로 평가될 필요가 있다. 또한 크립 등과 같이 고온응력 부하상태에서의 변형거동과 탄성계수 및 선 팽창계수의 온도의존성 등은 전선의 이도관리와 예측을 위해서도 명확히 규명되어야할 중요한 관리 인자이다. 그러나 현재까지는 이들에 대해 수행한 어떠한 연구결과들도 보고 되어 있지 않은 실정이다. 본 연구에서는 STACIR/AW $410mm^2$ 송전선을 장시간 운전의 모의를 위해 가속열화 시키고 가속열화에 따른 STACIR/AW전선 및 그 구성소재의 강도, 비틀림 특성의 변화를 조사하여 장시간 운전에 따른 STACIR/AW전선의 안정성을 평가하여 보고하고자 하였다.

  • PDF

신경신호 기록을 위한 PZT기반 마이크로 드라이브 (Miniature PZT actuated microdrive for chronic neural recording in small animals)

  • 박상규;박현준;박석호;김병규;신희섭;이석찬;김희수;김은태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.38-40
    • /
    • 2005
  • Microdrive with high precision and light mass enough to install on mouse head was fabricated for recording the reliable signal of neuron cell to understand the brain study. The proposed microdrive has three H-form PZT actuators and its guide structure. The microdrive operation principle is based on the well known inchworm principle. The synchronization of three PZT actuators is able to produce the linear motion along the guide structure. Our proposed microdrive has a precise accuracy of about 100nm and a long stroke of about 5mm. The electrode which is used for the recording of the action potential of the neuron cell was fixed at one of PZT actuators. The proposed microdrive was suited to acquisition of signals from in vivo extra-cellular single-unit recoding. On the condition of the anesthetized mouse, the single-unit signals could be recorded by using the proposed microdrive. In addition, applying the PZT microdrive to an alert mouse, we try to implant it on a mouse brain skull to explore single neuron firing.

  • PDF

디젤오염토양 복원 효율 증진을 위한 음이온/비이온 계면활성제 토양세척공정에 초음파 적용 영향 (The Effect of Ultrasound Application to Anionic/Non-ionic Surfactant Aided Soil-washing Process for Enhancing Diesel Contaminated Soils Remediation)

  • 조상현;손영규;남상건;최명찬;김지형
    • 한국환경과학회지
    • /
    • 제19권2호
    • /
    • pp.247-254
    • /
    • 2010
  • Ultrasound and Surfactant aided soil washing process has been shown to be an effective method to remove diesel from soils. The use of surfactants can improve the mobility of diesel in soil-water systems by increasing solubility of adsorbed diesel into surfactant micelles. However, a large amount of surfactant is required for treatment. In addition, synthetic surfactants, specially anionic, are more toxic and the surfactant wastewater is hard to treat by conventional wastewater treatments even by AOPs. Ultrasound improves desorption of the diesel adsorbed on to soil. The mechanisms are based on physical breakage of bonds by hot spot, directly impact onto soil particle surface, the fragmentation of long-chain hydrocarbons by micro-jet and microstreaming in the soil pores. The use of ultrasound as an enhancement method in both anionic and nonionic surfactant aided soil-washing processes were studied. And all experiments were examined proceeded under CMC surfactant concentration, frequency 35 khz, power 400 W, Soil-water ratio 1:3(wt%), particle size 0.24 ~ 2mm and initial diesel concentration. 20,000 mg/kg. Combination with ultrasound showed significant enhancements on all the processes. Especially, nonionic surfactant Triton-X100 with ultrasound showed remarkable enhancements and diesel removal rate enhanced by ultrasound helps desorpting of surfactant adsorbed onto soils which prevented decreasing surfactant activity.

종골 골절후 발생한 족부 구획 증후군의 치료 (Treatments of the Compartment Syndrome of the Foot after the Calcaneal Fractures)

  • 박용욱;정영기;유정한;전득수;황필성
    • 대한족부족관절학회지
    • /
    • 제3권1호
    • /
    • pp.12-18
    • /
    • 1999
  • Eleven patients with calcaneal fracture had 2 acute compartment syndrome of the feet and 9 late complication of the compartment syndrome of the feet. An interstitial pressure of more than 30 mmHg in either the central or interosseous compartment was considered pathologic and was treated by fasciotomy performed medially. Rigid claw toe deformity was treated by excision of the head and neck of the proximal phalanx, dorsal capsular release of the metatarsophalangeal joint, and lengthening of the extensor tendon. Patients were evaluated at a mean of 35 months(range, 21 - 44 months) after operation, and the examination was directed specifically toward symptoms and signs of myoneural ischemia, and walking pain. At follow -up, 2 patients with acute compartment syndrome of the foot had no evidence of myoneural ischemla, 9 patients with claw toe deformity had no pain with walking. Based on our clinical observations, we concluded that compartment syndrome of the foot may occur after the calcaneal fracture and fasciotomy is effective treatment for the prevention of the long term sequelae of this debilitating condition.

  • PDF

백서에서 자가 구강점막세포와 혈소판 농축 혈장의 이식에 의한 점막 근 피판의 조직공학적 제작 (FABRICATION OF TISSUE ENGINEERED MYO-MUCOSAL FLAP BY GRAFTING THE COMPLEX OF AUTOLOGOUS ORAL KERATINOCYTES AND PLATELET RICH PLASMA(PRP) IN A RAT MODEL)

  • 이부규;황진혁
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.322-330
    • /
    • 2007
  • Backgrounds: To overcome limited amount of autogenous mucosa for the reconstruction of various mucosal defect including oral mucosal defect, tissue engineered mucosa has been recently introduced. However, introduced conventional technique of tissue engineered mucosa still have serious pitfalls such as long fabrication time, fragility of the reconstructed mucosa, and complexity of the technique. Aim of the study: To examine whether the complex of preconfluent autologous keratinocytes and autologous PRP(Platelet rich plasma) can reconstruct oral mucosa on the muscular flap with easier and faster way compared to conventional mucosal tissue engineering technique. Materials and methods: One day before the operation, oral mucosa(3mm in diameter) were taken and treated for extraction of oral keratinocytes according to the routine manner. The day of operation, oral keratinocytes were prepared in the laboratory and then moved to the operating theater. Autologous PRP was also prepared and then mixed with oral keratinocytes just before grafting on the prepared muscular flap. After keratinocyte-PRP complex was seated, then a sterilized rubber sheet was placed on the graft and the elevated skin flap was replaced and sutured. Biopsies were proceeded at 3, 5, 7, 14 and 21 days. Tissue samples were evaluated clinically, histologically, and immunohistochemically. Results: All of the oral keratinocyte-PRP complexes were successfully grafted on the recipient sites(100%). On 3 days after the operation, 1-2 continuous epithelial layer and many inflammatory cells were observed. On 5 days after the operation, increase of layers of keratinocyte was observed with less inflammatory response. Thickness of the layers was gradually increased from 7 to 21 days after the operation. Cytokeratin confirms epithelium in every specimen. Conclusions: Preconfluent graft of autogenous oral keratinocytes mixed with autogenous PRP have successfully reconstructed myo-mucosal flap. This technique could be a useful alternative for oral mucosal reconstruction in the near future.

Discovery of an elliptical jellyfish galaxy with MUSE

  • Sheen, Yun-Kyeong;Smith, Rory;Jaffe, Yara;Kim, Minjin;Duc, Pierre-Alain;Ree, Chang Hee;Nantais, Julie;Candlish, Graeme;Yi, Sukyoung;Demarco, Ricardo;Treister, Ezequiel
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.46.2-46.2
    • /
    • 2017
  • We will present a discovery of an elliptical jellyfish galaxy in Abell 2670 (Sheen et al. 2017, ApJL, 840, L7). Our MUSE IFU spectra revealed a rotating gas disk in the center of the galaxy and long ionised gas tails emanating from the disk. Its one-sided tails and a tadpole-like morphology of star-forming blobs around the galaxy suggested that the galaxy is experiencing strong ram-pressure stripping in the cluster environment. Stellar kinematics with stellar absorption lines in the MUSE spectra demonstrated that the galaxy is an elliptical galaxy without any hint of a stellar disk. Then, the primary question would be the origin of the rich gas component in the elliptical galaxy. A plausible scenario is a wet merger with a gas-rich companion. In order to investigate star formation history of the system (the galaxy and star-forming blobs), we derived star-formation rate and metallicity from the MUSE spectra. Photometric UV-Optica-IR SED fitting was also performed using GALEX, SDSS, 2MASS and WISE data, to estimate dust and gas masses in the system. For a better understanding of star formation history and environmental effect of this galaxy, FIR/sub-mm follow-up observations are proposed.

  • PDF