• Title/Summary/Keyword: mm Wave

Search Result 1,023, Processing Time 0.034 seconds

Modern Laser Technology and Metallurgical Study on Laser Materials Processing

  • Kutsuna, Muneharu
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.561-569
    • /
    • 2002
  • Laser has been called a "Quantum Machine" because of its mechanism of generation since the development on July 7,1960.by T.H.Maiman. We can now use this machine as a tool for manufacturing in industries. At present, 45kW CO2 laser, 10kW Nd:YAG laser, 6kW LD pumped YAG laser and 4kW direct diode laser facilities are available for welding a heavy steel plate of 40mm in thickness and for cutting metals at high speed of 140m/min. Laser Materials Processing is no longer a scientific curiosity but a modern tool in industries. Lasers in manufacturing sector are currently used in welding, cutting, drilling, cladding, marking, cleaning, micro-machining and forming. Recently, high power laser diode, 10kW LD pumped YAG laser, 700W fiber laser and excimer laser have been developed in the industrialized countries. As a result of large numbers of research and developments, the modem laser materials processing has been realized and used in all kinds of industries now. In the present paper, metallurgical studies on laser materials processing such as porosity formation, hot cracking and the joint performances of steels and aluminum alloys and dissimilar joint are discussed after the introduction of laser facilities and laser applications in industries such as automotive industry, electronics industry, and steel making industry. The wave towards the use of laser materials processing and its penetration into many industries has started in many countries now. Especially, development of high power/quality diode laser will be accelerate the introduction of this magnificent tool, because of the high efficiency of about 50%, long life time and compact.

  • PDF

A Case of Supravalvular Pulmonic Stenosis in a Maltese Dog (말티즈견에서 발생한 판막상형 폐동맥판 협착증 증례)

  • Kim, Seong-Jun;Kang, Min-Hee;Kim, Su-Chan;Choi, Young-Chul;Kim, Seung-Gon;Lee, Chang-Min;Jung, Da-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.325-328
    • /
    • 2014
  • A 8-month-old female Maltese dog was presented with a history of heart murmur. In physical examination, grade 4/6 systolic murmur heard at the left heart base. Electrocardiography showed sinus arrhythmia, right axis deviation, deep S wave and splintered QRS complex. Thoracic radiography revealed enlarged right side heart and bulging of the main pulmonary artery. Echocardiography showed mild hypertrophy of right ventricle, a supravalvular stenosis, marked post-stenotic dilation of the main pulmonary artery and a moderately increased pulmonary arterial velocity through the stenotic area (4.4 m/s, pressure gradient of 78.7 mmHg). The dog was diagnosed with supravalvular pulmonic stenosis based on the diagnostic imaging findings. Medical management using ${\beta}1$-blocker and ACE inhibitor was started in this dog and this is first case report described diagnostic characteristic features of supravalvular pulmonic stenosis in korea.

High-Throughput QC-LDPC Decoder Architecture for Multi-Gigabit WPAN Systems (멀티-기가비트 WPAN 시스템을 위한 고속 QC-LDPC 복호기 구조)

  • Lee, Hanho;Ajaz, Sabooh
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.104-113
    • /
    • 2013
  • A high-throughput Quasi-Cyclic Low-Density Parity-Check (QC-LDPC) decoder architecture is proposed for 60GHz multi-gigabit wireless personal area network (WPAN) applications. Two novel techniques which can apply to our selected QC-LDPC code are proposed, including a four block-parallel layered decoding technique and fixed wire network. Two-stage pipelining and four block-parallel layered decoding techniques are used to improve the clock speed and decoding throughput. Also, the fixed wire network is proposed to simplify the switch network. A 672-bit, rate-1/2 QC-LDPC decoder architecture has been designed and implemented using 90-nm CMOS standard cell technology. Synthesis results show that the proposed QC-LDPC decoder requires a 794K gate and can operate at 290 MHz to achieve a data throughput of 3.9 Gbps with a maximum of 12 iterations, which meet the requirement of 60 GHz WPAN applications.

A laser Doppler study of gingival blood flow change following periosteal stimulation (골막 자극 후 Laser Doppler Flowmetry를 이용한 치은혈류량 변화)

  • Lee, Ji-Young;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.139-147
    • /
    • 2003
  • The roots of teeth exposed by gingival recession, may be successfully covered by various type of gingival grafting procedures. Vascularization of the recipient site is an essential determinant of the grafts' survival during the first healing stages. It has been suggested that a procedure by which they stimulate the periosteum presurgically will induce the proliferation of neo-endothelium in the site to be operated. The purpose of this study is to evaluate the variations in the gingival blood flow during 4weeks after periosteal stimulation in patient scheduled to receive gingival grafts and to compare variations in the gingival blood flow between smoker and non-smoker. Laser Doppler Flowmetry(floLAB(R), Moor Instruments Ltd, England ; wave length = 780mm. Max. power =l.6mW) was used to measure the gingival blood flow. 112 sites of 68 male patients (32 smokers and 36 non-smoker), aged between 23 and 48 years (smoker : 24-44 years. mean=32.6, non-smoker : 23-48 years, mean=28.5) were monitored for the blood flow. Gingival blood flow measured at before periosteal stimulation, 1-, 2-, 3-, and 4-weeks after periosteal stimulation from 10 a.m. to 2 p.m. The difference of blood flow in each measuring time, each measuring site and between smokers and non-smokers were statistically analyzed by MANOVA. The results were as follows : (1) Blood flow stayed increased for 2 weeks, and then, it was a tendency to decrease(p<0.05). (2) There was no statistically significant difference of blood flow change between smokers and non-smokers. (3)The blood flow at middle site had lower than mesial and distal site during the measuring periods(p<0.05). The present study suggested that blood flow change following periosteal stimulation was significant difference, thus periosteal stimulation before gingival graft might induce favorable results in gingival recession patient.

Design of a 40 GHz CMOS Phase-Locked Loop Frequency Synthesizer Using Wide-Band Injection-Locked Frequency Divider (광대역 주입동기식 주파수 분주기 기반 40 GHz CMOS PLL 주파수 합성기 설계)

  • Nam, Woongtae;Sohn, Jihoon;Shin, Hyunchol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.717-724
    • /
    • 2016
  • This paper presents design of a 40 GHz CMOS PLL frequency synthesizer for a 60 GHz sliding-IF RF transceiver. For stable locking over a wide bandwith for a injection-locked frequency divider, an inductive-peaking technique is employed so that it ensures the PLL can safely lock across the very wide tuning range of the VCO. Also, Injection-locked type LC-buffer with low-phase noise and low-power consumption is added in between the VCO and ILFD so that it can block any undesirable interaction and performance degradation between VCO and ILFD. The PLL is designed in 65 nm CMOS precess. It covers from 37.9 to 45.3 GHz of the output frequency. and its power consumption is 74 mA from 1.2 V power supply.

Comparative study of wound healing in canine stomach with CO2 laser and scalpel incisions (CO2 레이저와 scalpel을 이용한 위 절개 시 개에서의 창상 치유 평가)

  • Lee, Jae-Yeon;Hwang, You-Sun;Kim, Han-Kyul;Choi, Hyun-Suk;Jeong, Seong-Mok;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • The objective of this study was to compare wound healing in stomach with $CO_{2}$ laser and scalpel incision by measuring the extent of bleeding, the ease of gastric incision, incision time, degree of adhesion and wound healing degree in dogs. Sixteen healthy dogs were used. Two symmetrical incisions were made in ventral aspect of the stomach between the greater and lesser curvatures were made with scalpel and 0.2 mm spot diameter $CO_{2}$ laser (8W, continuous wave) in sixteen dogs. And then each wound was closed with absorbable suture in a two-layer inverting seromuscular pattern. At 3, 7, 14 and 21 days after initial wounding, each wound was taken for histological observation. On surgery, the extent of bleeding, the ease of incision and incision time showed significant differences between the groups. The $CO_{2}$ laser provided better hemostasis (p < 0.05) and smaller postoperative adhesion compared with the scalpel. However, the scalpel produced faster speed of incision and was easier to handle than the $CO_{2}$ laser (p < 0.05). Although there was no considerable difference between the two groups in histological observation, necrosis and calcium deposit tended to be larger in the $CO_{2}$ laser than in the scalpel.

Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy (경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성)

  • Lim, Jeong-Hwan;Song, Jun-Hyeok;Shin, Kyu-Man;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF

The Performance of Micro Fluxgate Sensor with Magnetic Core Shape (자성체 코어 형상에 따른 마이크로 플럭스게이트 센서의 검출 특성)

  • 조중희;최원열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.508-514
    • /
    • 2004
  • A fluxgate magnetic sensor consists of a solenoid excitation coil, pick-up coil, and magnetic core. We presents the effect of magnetic core shape in a micromachined fluxgate sensor. To observe the performance of fluxgate sensor with magnetic core side width and gap, side width of 125 ${\mu}{\textrm}{m}$, 250 ${\mu}{\textrm}{m}$, and 500 ${\mu}{\textrm}{m}$ were designed in a rectangular-ring shaped core and the gaps of 0 ${\mu}{\textrm}{m}$, 50 ${\mu}{\textrm}{m}$, and 100 ${\mu}{\textrm}{m}$ were also fabricated in a racetrack shaped core. The solenoid coils and magnetic core were separated by benzocyclobutane(BCB) which had high insulation and good planarization characters. Copper coil patterns of 10 ${\mu}{\textrm}{m}$ width and 6${\mu}{\textrm}{m}$ thickness were electroplated on Ti(300 $\AA$) / Cu(1500 $\AA$) seed layers. 3 ${\mu}{\textrm}{m}$ thick N $i_{0.8}$F $e_{0.2.}$(permalloy) film for the magnetic core was also electroplated under 2000 gauss to induce the magnetic anisotropy. The magnetic core had the high DC effective permeability of ∼1,300 and coercive field of ∼0.1 Oe. Because the magnetic cores of 500 ${\mu}{\textrm}{m}$ side width and 0 gap had a low magnetic flux leakage, high sensitivity of ∼350 V/T were measured at excitation condition of 3 $V_{P-P}$ and 2 MHz square wave. The power consumption of ∼14 ㎽ was measured. The fabricated fluxgate sensor had the very small actual size of 3.0${\times}$1.7 $\textrm{mm}^2$. When two fluxgates were perpendicularly aligned in terrestrial field, their two-axis output signals were very useful to commercialize an electronic azimuth compass for the portable navigation system.m.m.m.

A STUDY ON THE FRACTURE TOUGHNESS OF DENTAL COMPOSITE RESINS (치과용 복합레진의 파괴인성에 관한 실험적 연구)

  • Park, Jin-Hoon;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.17-33
    • /
    • 1990
  • The purpose of this study was to evaluate the fracture toughness of dental composite resins and to investigate the filler factor affecting the fracture behaviour on which the degree of fracture toughness depends. Six kinds of commercially available composite resin;, including two of each macrofilled, microfilled, and hybrid type were used for this study, The plane strain fracture toughness ($K_{10}$) was determined by three-point bending test using the single edge notch specimen according to the ASTM-E399. The specimens were fabricated with visible light curing or self curing of each composite resin previously inserted into a metal mold, and three-point bending test was conducted with cross-head speed of 0.1mm/min following a day's storage of the specimens in $37^{\circ}C$ distilled water. The filler volume fractions were determined by the standard ashing test according to the ISO-4049. Acoustic Emission(AE), a nondestructive testing method detecting the elastic wave released from the localized sources In material under a certain stress, was detected during three-point bending test and its analyzed data was compared with, canning electron fractographs of each specimen. The results were as follows : 1. The filler content of composite resin material was found to be highest in the hybrid type followed by the macrofilled type, and the microfilled type. 2. It was found that the value of plane strain fracture toughness of composite resin material was in the range from 0.69 MPa$\sqrt{m}$ to 1 46 MPa$\sqrt{m}$ and highest In the macrofilled type followed by the hybrid type, and the microfilled type. 3. The consequence of Acoustic Emission analysis revealed that the plane strain fracture toughness increased according as the count of Acoustic Emission events increased. 4. The higher the plane strain fracture toughness became, the higher degree of surface roughness and irregularity the fractographs demonstrated.

  • PDF

Unsteady Flow with Cavitation in Viscoelastic Pipes

  • Soares, Alexandre K.;Covas, Didia I.C.;Ramos, Helena M.;Reis, Luisa Fernanda R.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.269-277
    • /
    • 2009
  • The current paper focuses on the analysis of transient cavitating flow in pressurised polyethylene pipes, which are characterized by viscoelastic rheological behaviour. A hydraulic transient solver that describes fluid transients in plastic pipes has been developed. This solver incorporates the description of dynamic effects related to the energy dissipation (unsteady friction), the rheological mechanical behaviour of the viscoelastic pipe and the cavitating pipe flow. The Discrete Vapour Cavity Model (DVCM) and the Discrete Gas Cavity Model (DGCM) have been used to describe transient cavitating flow. Such models assume that discrete air cavities are formed in fixed sections of the pipeline and consider a constant wave speed in pipe reaches between these cavities. The cavity dimension (and pressure) is allowed to grow and collapse according to the mass conservation principle. An extensive experimental programme has been carried out in an experimental set-up composed of high-density polyethylene (HDPE) pipes, assembled at Instituto Superior T$\acute{e}$cnico of Lisbon, Portugal. The experimental facility is composed of a single pipeline with a total length of 203 m and inner diameter of 44 mm. The creep function of HDPE pipes was determined by using an inverse model based on transient pressure data collected during experimental runs without cavitating flow. Transient tests were carried out by the fast closure of the ball valves located at downstream end of the pipeline for the non-cavitating flow and at upstream for the cavitating flow. Once the rheological behaviour of HDPE pipes were known, computational simulations have been run in order to describe the hydraulic behaviour of the system for the cavitating pipe flow. The calibrated transient solver is capable of accurately describing the attenuation, dispersion and shape of observed transient pressures. The effects related to the viscoelasticity of HDPE pipes and to the occurrence of vapour pressures during the transient event are discussed.