• Title/Summary/Keyword: mm Wave

Search Result 1,023, Processing Time 0.029 seconds

Application of Electromagnetic Wave for Evaluating Necking Defects in Bored Piles (현장타설말뚝의 네킹 결함 평가를 위한 전자기파의 적용성 연구)

  • Lee, Jong-Sub;Song, Jung Wook;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The objective of this study is to demonstrate the suitability of electromagnetic waves for evaluating necking defects in bored piles using electromagnetic waves. Experiments are conducted with small-scaled defective model pile with diameter of 150 mm and length of 270 mm. Two necking defects are generated at the upper and lower positions on two different sides of the model pile, respectively. The other two necking defects are generated at the upper and lower positions on the same side of the model pile. Electrical wires are installed alongside the stainless steel wire of a steel cage to configure a two-conductor transmission line. A time-domain reflectometer is used to generate and defect electromagnetic waves. The experimental results show that electromagnetic waves are reflected at the necking defects and the end of the model pile. In addition, calculated defect locations are almost the same as actual defect locations. This study demonstrates that electromagnetic waves can be effective tool for evaluating necking defects in bored piles.

Detection and Sizing of Fatigue Cracks in Thin Aluminum Panel with Rivet Holes (리벳구멍을 가진 알루미늄 패널에서 피로균열의 탐지와 균열길이 측정)

  • Kim, Jung-Chan;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.38-47
    • /
    • 2007
  • The initiation of fatigue cracks in a simulated aircraft structure with a series of rivet holes was detected by acoustic emission(AE), then the crack length was determined by surface acoustic wave(SAW) technique. With the initiation and growth of fatigue cracks, AE events increased intermittently to form a stepwise incremental curve of cumulative AE events whereas the crack length increased more or less monotonically. With the SAW technique employed, the crack sizing for 13 different cracks including some short cracks was performed. With the reference to the measurement by traveling microscope, cracks in the range of $1{\sim}8mm$ long were reliably sized by the SAW technique. Although it was impossible to size the short fatigue cracks in the range shorter than 1 mm, the SAW technique still appeared practically useful for a range of crack lengths often found in aircraft structures.

Modeling of Electromagnetic Wave Propagation for Detection of Bond Delamination in Concrete (콘크리트 보강재 박리 검사를 위한 전자파 모델링)

  • 남연수;임홍철
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.3
    • /
    • pp.261-269
    • /
    • 2004
  • The existing concrete beams can be retrofitted or reinforced by attaching carbon fiber or glass fiber sheet beneath the beams. Although diverse design methods and application techniques of the retrofitting are studied and developed, the testing method of examining retrofitted beams have not been put into practice yet. In this study, a bond delamination has been modeled and studied to provide a basis for the development of actual testing equipments. For this purpose, Gaussian and sinusoidal waves with 3GHz and 5GHz center frequency are used as an incident wave and 1mm and 3mm bond delamination under the reinforcement are modeled. In the modeling, Finite Difference-Time Domain algorithm is used to investigate the behavior of electromagnetic waves in concrete. The results have shown that 5GHz waves are suitable for the detection of delamination.

A Study on Radiographic Equipments and Situation for the Chest (흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査))

  • Ko, Shin-Gwan;An, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

Electrophysiological Study on Medullospinal Tract Cells Related to Somatosympathetic Reflex in the Cat

  • Kim, Sang-Jeong;Goo, Yong-Sook;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • v.26 no.1
    • /
    • pp.75-88
    • /
    • 1992
  • It is well established that neurons in ventrolateral medulla play a key role in determining the vasomotor tone. The purpose of present study is to identify sympathetic related, medullospinal tract neurons in ventrolateral medulla and to show that these mediate somato-sympathetic reflex. Medullospinal tract cells were identified by antidromic stimulation to intermediolateral nucleus (IML) of the second thoracic ($T_2$) spinal cord in anesthetized cats. Peripheral nerves were stimulated for orthodromic activation of these cells and peripheral receptive fields were determined. Post R wave histogram of unit and spike triggered averaging of sympathetic nerve discharge (SND) were used to define sympathetic related cell. A total of 113 neurons was recorded in ventrolateral medulla that had the axonal projections to $T_2$ spinal cord. Thirty four of these medullospinal cells showed spontaneous discharges and the others not. Between these two groups, rostro-caudal coordinate of the distribution from obex [$4.7{\pm}0.2\;$ (mean S.E.) mm, 4.1 0.1 mm], depth from dorsal surface ($5.5{\pm}0.2mm,\;4.9{\pm}0.1mm$ and conduction velocity ($9.9{\pm}1.7m/sec,\;16.7{\pm}1.9\;m/sec$) were significantly different (p<0.05). In spontaneously discharging group, characteristics of rostral and caudal groups were significantly different and we demonstrated that cells in rostral group mediate somatosympathetic reflex. From these results, we conclude that a certain portion of spontaneously discharging medullospinal tract cells in rostral ventrolateral medulla comprise the efferent outputs of somatosympathetic reflex to sympathetic preganglion neurons.

  • PDF

Fabrication of Phased Array EMAT and Its Characteristics (위상배열 EMAT의 제작 및 특성 평가)

  • Ahn, Bong-Young;Cho, Seung-Hyun;Kim, Young-Joo;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • EMAT has been applied in various fields for flaw detection and material characterization because it has noncontact property in wave generation and a good mode selectivity. Unfortunately, however, EMAT shows low signal to noise ratio relative to commercial contact transducer because of low energy conversion efficiency. If the phase matching through the control of time delay between each coil consisting of the array EMAT is accomplished, it is expected that it will be a solution for the improvement of low signal to noise ratio. In this experiment, the phased array EMATs which consists of 3 or 4 meander coils and one big magnet were fabricated for surface and vertical shear wave generation. Effect of phased delay control on signal directivity and amplitude enhancement was verified. A slit with the depth of 0.5 mm and a side-drill hole of 0.5 mm diameter were clearly detected by fabricated phased array EMATs, respectively.

Analysis and fabrication of a wearable antenna using conductive fibers (전도성 실 재질을 이용한 웨어러블 안테나의 제작 및 분석)

  • Nguyen, Tien Manh;Chung, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2770-2776
    • /
    • 2015
  • The development of efficient wearable antennas is required to implement short range body-centric wireless communication links for various internet of thing applications. We present simulation and measurement results of conductive-fiber-based wearable antennas which can comfortably fabricated directly on usual clothing materials. The proposed antenna is a form of a rectangular patch antenna designed by weaving conductive fibers on a felt substrate. A full-wave electromagnetic simulation tool is used to investigate the antenna performance such as antenna impedance, resonant frequency, and radiation efficiency. Parametric studies show that the radiation efficiency increases from 67.5% to 70.4% by widening the gap between conductive fibers from 0.25mm to 3mm. This implies a wearable antenna with good radiation efficiency can be designed despite of less portion of conductive fibers on the antenna. The simulation results are also verified by measured results with fabricated antennas.

Experimental Study of Micro-Shock Tube Flow (Micro-Shock Tube 유동에 대한 실험적 연구)

  • Park, Jin-Ouk;Kim, Gyu-Wan;Rasel, Md. Alim Iftakhar;Kim, Heuy-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.5
    • /
    • pp.385-390
    • /
    • 2015
  • The flow characteristics in micro shock tube are investigated experimentally. Studies were carried out using a stainless steel micro shock tube. Shock and expansion wave was measured using 8 pressure sensors. The initial pressure ratio was varied from 4.3 to 30.5, and the diameter of tube was also changed from 3mm to 6mm. Diaphragm conditions were varied using two types of diaphragms. The results obtained show that the shock strength in the tube becomes stronger for an increase in the initial pressure ratio and diameter of tube. For the thinner diaphragm, the highest shock strength was found among varied diaphragm condition. Shock attenuation was highly influenced by the diameter of tube.

A 15-GHz CMOS Multiphase Rotary Traveling-Wave Voltage-Controlled Oscillator

  • Zhang, Changchun;Wang, Zhigong;Zhao, Yan;Park, Sung-Min
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.255-265
    • /
    • 2012
  • This paper presents a 15-GHz multiphase rotary traveling-wave voltage-controlled oscillator (RTW VCO) where a shielded coplanar stripline (CPS) is exploited to provide better shielding protection and lower phase noise at a moderate cost of characteristic impedance and power consumption. Test chips were implemented in a standard 90-nm CMOS process, demonstrating the measured results of 2-GHz frequency tuning range, -11.3-dBm output power, -109.6-dBc/Hz phase noise at 1-MHz offset, and 2-ps RMS clock jitter at 15 GHz. The chip core occupies the area of $0.2mm^2$ and dissipates 12 mW from a single 1.2-V supply.

PZT membrane Piezoelectric Traveling Wave Motor

  • xin, Shen-De;an, Zhang-Bao;Lu jinan-guo;qing, Yang-Gen;yuan, Wang-Wei
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.89-95
    • /
    • 1997
  • A new type of piexoelectric membrane traveling wave motor has been designed and forbricated. The small motor is composed by the stator which is the combination of annular/circular membrane and metal elastic base using as the common electrode at some time and the rotor which is placed on the metal elastic body. Thus the motor structure is simple and easy to fabricate. The material of a piezoelectric membrane is fabricated by sol-gel method or wear-down method. A piezoelectric traveling wave motor has been fabricated with the stator diameter 8mm The total thickness of the stator is 350$\mu$m. Under the alternative excitation voltage 10-12V the revolving speed of the rotor is more than 100RPM.

  • PDF