• Title/Summary/Keyword: mm Wave

Search Result 1,020, Processing Time 0.029 seconds

Analysis of Parameters Affecting the Attenuation by Rain in Ka and mm-wave Bands (Ka 및 mm파 대역에서 강우감쇠에 영향을 주는 파라미터 분석)

  • 김정효;유명완;김희찬;류규태;이범선;김영수;서덕영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.242-251
    • /
    • 2000
  • Design of wireless link in Ka and mm-wave bands is critically affected by rain attenuation. In this paper, we compared and analyzed the main distributions of rain drop size to estimate the rain attenuation which can be used in domestic environment. Mie scattering theory was checked to agree with Rayleigh theory in its low frequency limit and agree with optical scattering theory in its high frequency limit. We intended to provide more specific criteria to estimate rain attenuation with a generalized approach.

  • PDF

Adaptation of impactor for the split Hopkinson pressure bar in characterizing concrete at medium strain rate

  • Zhao, Pengjun;Lok, Tat-Seng
    • Structural Engineering and Mechanics
    • /
    • v.19 no.6
    • /
    • pp.603-618
    • /
    • 2005
  • The split Hopkinson pressure bar (SHPB) technique is widely used to characterize the dynamic mechanical response of engineering materials at high strain rates. In this paper, attendant problems associated with testing 70 mm diameter concrete specimens are considered, analysed and resolved. An adaptation of a conventional solid circular striker bar, as a means of achieving reliable and repeatable SHPB tests, is then proposed. In the analysis, a pseudo one-dimensional model is used to analyse wave propagation in a non-uniform striker bar. The stress history of the incident wave is then obtained by using the finite difference method. Comparison was made between incident waves determined from the simplified model, finite element solution and experimental data. The results show that the simplified method is adequate for designing striker bar shapes to overcome difficulties commonly encountered in SHPB tests. Using two specifically designed striker bars, tests were conducted on 70 mm diameter steel fibre reinforced concrete specimens. The results are presented in the paper.

Forming of Metallic Bipolar Plates by Dynamic Loading (Dynamic Load를 이용한 박막 금속 분리판 성형기술)

  • Koo, J.Y.;Kang, C.G.
    • Transactions of Materials Processing
    • /
    • v.21 no.1
    • /
    • pp.5-12
    • /
    • 2012
  • The weight of the bipolar plate is one of the crucial aspects of improving power density in PEMFC stacks. Aluminum alloys have good mechanical properties such as density, electrical resistivity, and thermal conductivity. Furthermore, using aluminum in a bipolar plate instead of graphite reduces the bipolar plate cost and makes machining easier. Therefore in this study, an aluminum alloy was selected as the appropriate material for a bipolar plate. Results from feasibility experiments with the aim of developing fuel cells consisting of Al bipolar plates with multiple channels are presented. Dynamic loading was applied and the formability of micro channels was estimated as a function of punch pressure and die radius. Sheets of Al5052 with a thickness of 0.3mm were used. For a die radius of 0.1mm the formability was optimized with a sine wave dynamic load of 90kN at maximum pressure and 5 cycles of a sine wave punch travel. The experimental results demonstrate the feasibility of the proposed manufacturing technique for producing bipolar plates.

ANALYSIS OF TEMPERATURE RISE ON THE ROOT SURFACE DURING CONTINUOUS WAVE OF CONDENSATION TECHNIQUE (Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석)

  • Kim, Young-Ju;Hwang, Yun-Chan;Kim, Sun-Ho;Hwang, In-Nam;Choi, Bo-Young;Jeong, Young-Jin;Juhng, Woo-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.341-347
    • /
    • 2003
  • This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1 mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed $130.82{\pm}2.96^{\circ}C,{\;}158.00{\pm}5.26^{\circ}C,{\;}215.92{\pm}6.91^{\circ}C{\;}and{\;}249.88{\pm}3.65^{\circ}C$ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.0l). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was $2.37{\pm}0.09^{\circ}C{\;}at{\;}150^{\circ}C{\;}setting,{\;}3.11{\pm}0.12^{\circ}C{\;}at{\;}200^{\circ}{\;}setting,{\;}3.93{\pm}0.09^{\circ}C{\;}at{\;}250^{\circ}C{\;}setting{\;}and{\;}5.69{\pm}0.15^{\circ}C{\;}at{\;}300^{\circ}C$ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings on digital temperature display of System B HeatSource.

Visualization Study of Wave Generation in Short-Distance Wave Maker (소형 조파기 내의 조파생성에 대한 가시화연구)

  • Jung, Eui-Chul;Yuan, Zhen-Zhong;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.293-300
    • /
    • 2013
  • This study used a water tank and wave maker to generate conditions similar to the real ocean environment. Given that the waves were properly generated in the water tank, a precise analysis indicated the quantitative value of the wave force acting on a body. A high-speed camera and wave-level gauge were used to measure the temporal wave motion and period. A series of artificial water waves were successfully generated using three different wave periods and amplitudes. Each of the waves captured by a high-speed camera was sinusoidal and did not maintain its shape properly without a wave absorber, but it was substantially improved and well shaped when the wave absorber was installed.

Two-dimensional water seepage monitoring in concrete structures using smart aggregates

  • Zou, Dujian;Li, Weijie;Liu, Tiejun;Teng, Jun
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.2
    • /
    • pp.313-323
    • /
    • 2018
  • The presence of water inside concrete structures is an essential condition for the deterioration of the structures. The free water in the concrete pores and micro-cracks is the culprit for the durability related problems, such as alkali-aggregate reaction, carbonation, freeze-thaw damage, and corrosion of steel reinforcement. To ensure the integrity and safe operation of the concrete structures, it is very important to monitor water seepage inside the concrete. This paper presents the experimental investigation of water seepage monitoring in a concrete slab using piezoelectric-based smart aggregates. In the experimental setup, an $800mm{\times}800mm{\times}100mm$ concrete slab was fabricated with 15 SAs distributed inside the slab. The water seepage process was monitored through interrogating the SA pairs. In each SA pair, one SA was used as actuator to emit harmonic sine wave, and the other was used as sensor to receive the transmitted stress wave. The amplitudes of the received signals were able to indicate the water seepage process inside the concrete slab.

Effects of Pitch Length of Stack-type EGR Cooler on Heat Exchange Characteristics in a Diesel Engine (적층형 EGR Cooler의 Pitch 길이 변화가 열교환 특성에 미치는 영향)

  • Hwang, Se-Joon;Kim, Min-Chol;Jang, Sang-Hoon;Kim, Hyung-Man
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.135-140
    • /
    • 2010
  • An important goal in diesel engine research is the development of a means to reduce the emissions of nitrogen oxides (NOX). The use of a cooled exhaust gas recirculation (EGR) system is one of the most effective techniques currently available for reducing nitrogen oxides. Since Particular Matter (PM) fouling reduces the efficiency of an EGR cooler, a trade-off exists between the amount of NOX and PM emissions, especially at high engine loads. In the present study, engine dynamometer experiments have been performed to investigate the heat exchange characteristics of the stack-type EGR coolers with wave fin pitches of 3.6 and 4.6 mm. The results show that the heat exchange effectiveness is decreased as surface area decrease with pitch of 4.6 mm due to PM fouling. As surface area increase at pitch of 3.6 mm, super-cooling happens in the recirculated exhaust gas.

Electromagnetic Wave Absorbers with Metamaterial Structure for RCS Reduction (레이다 단면적 저감을 위한 메타물질 구조의 전자파 흡수체)

  • Lee, Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.1-15
    • /
    • 2015
  • In this invited paper, the authors give an overview of the new design technology for a metallic backplane-less metamaterial(MM) absorber and discuss a selection of examples. In contrast to a common MM absorber structure, the metallic pattern layer of the presented structure is placed facing toward the incident wave propagation direction to reduce the radar cross section(RCS) due to the metallic pattern itself at frequencies other than the targeted absorption frequency bands. The ability of the MM backplane-less absorber to exhibit broadband absorption performance and irregular surface applications will be discussed.

THE EFFECT OF OBTURATION TECHNIQUES ON THE APICAL MICROLEAKAGE OF ROOT CANALS (근관충전방법에 따른 치근단부 근관의 미세누출에 관한 연구)

  • Yoo, Hyung-Jun;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.213-222
    • /
    • 1998
  • Advisor: Prof. The quality of apical seal obtained with 3 different gutta-percha obturation techniques was compared in 49 recently extracted single rooted teeth. The root canals were instrumented using step-back technique and obturated with laterally condensed gutta-percha, Continuous Wave gutta-percha, and hybrid technique. Teeth were suspended in black India ink for 7 days, cleared, and then examined under a stereomicroscope at ${\times}10$ magnification. The results were as follows; 1. All experimental groups produced favorable apical seal. 2. The mean leakage was $0.23{\pm}0.25mm$ for group 1, $0.17{\pm}0.21mm$ for group 2, and $0.19{\pm}0.23mm$ for froup 3, but there was no statistical difference amoung them. Within the limits of the results of this experiment, the Continuous Wave gutta-percha obturation technique demonstrated relatively favorable apical sealing effect and shorter obturation time. Thus, it is thought that this obturation technique is a acceptable method for clinical use but further studies on this metter should be conducted.

  • PDF

Evaluation of Resolution Characteristics by Using Chart Device Angle (차트 각도를 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.375-380
    • /
    • 2021
  • This study aim was quantitative assessment of MTFs of spectrum of the square wave chart images and Coltman chart images for 0°, 1.7°, 2.2°, 2.9°, 4.1° by using chart method. In general device was AccuRay-650 (DK Medical System, Korea) used, indirect flat panel detector(FPD) Aero (Konica, Japan) used and MATLAB R2019a (MathWorks, USA) used. The result of comparison for each angle of MTF the edge image was highest quantitatively value for MTF finding of showed the best value of 0.1 based on the frequency of 3.5 mm-1, value of 0.1 based on the square wave was frequency of 3.0 mm-1 and value of 0.1 based on the Coltman transform was frequency of 2.4 mm-1. In this study it was significant that the methodology of the international Electro-technical Commission was applied mutandis by using the Fujita method within 2~3°.