• Title/Summary/Keyword: mixed up

Search Result 1,718, Processing Time 0.029 seconds

The Mixed-Use Supertall and the Hybridization of Program

  • Bagley, Forth
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.1
    • /
    • pp.65-73
    • /
    • 2018
  • Increasingly, mixed-use, multi-program complexes are emerging as the standard development model around the world. As their prominence grows, these projects are becoming increasingly complex. Program adjacencies are ever more intertwined as developers (and the architects who support them) are becoming more comfortable blurring the traditional boundaries between office, retail, residential and hospitality. This article discusses a second generation of mixed-use projects that embrace this hybridization, honing in on supertall architecture, their hybrid program offerings, and innovative sky lobbies. It concludes that programmatic advancements will continue to expand and find integration within single structures, both repositioned and built from the ground up.

On Lagrangian Approach to Mixed $H_2$/H\ulcorner Control Problem: The State Feedback Case

  • Cho, Kwang-Hyun;Lim, Jong-Tae
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.1
    • /
    • pp.29-38
    • /
    • 1996
  • To improve the reliability of control systems, certain robustness to plant uncertainties and disturbance inputs is required in terms of well founded mathematical basis. Robust control theory was set up and developed until now from this motivation. In this field, H$_2$or H\ulcorner norm performance measures are frequently used nowadays. Moreover a mixed H$_2$/H\ulcorner control problem is introduced to combine the merits of each measure since H$_2$control usually makes more sense for performance while H\ulcorner control is better for robustness to plant perturbations. However only some partial analytic solutions are developed to this problem under certain special cases at this time. In this paper, the mixed H$_2$/H\ulcorner control problem is considered. The analytic(or semi-analytic) solutions of (sub)optimal mixed H$_2$/H\ulcorner state-feedback controller are derived for the scalar plant case and the multivariable plant case, respectively. An illustrative example is given to compare the proposed analytic solution with the existing numerical one.

  • PDF

Ready mixed concrete behavior of granulated blast furnace slag contained cement

  • Karim, M. Razaul;Islam, A.B.M. Saiful;Chowdhury, Faisal I.;Rehman, Sarder Kashif Ur;Islam, Md. Rabiul
    • Computers and Concrete
    • /
    • v.21 no.2
    • /
    • pp.139-147
    • /
    • 2018
  • Due to enhanced construction requirement, ready mixed concrete are being popular day by day. The current study aimed to develop ready mixed concrete using GBFS contained cement and determine its properties of fresh and hardened states. A real scale experiment was set up in a ready mixed plant for measuring workability and compressive strength. The workability was tested after mixing (within 5 minutes), 30, 60, 90, 120 and 150 minutes of the running of bulk carrier. The ready mixed carrier employed spinning motion i.e., rotating around its axis with 20 RPM and running on road with 1km/h speed. The mixing ratio of cement: sand:gravel, water to cement ratio, super plasticizer were, 1:1.73:2.47, 0.40 and 6% of cement, respectively. The chemical composition of raw material was determined using XRF and the properties of cements were measured according to ASTM standards. The experimental results confirm that the cement with composition of 6.89% of GBFS, 4% of Gypsum and 89.11% of clinker showed the good compressive strength and workability of concrete after 150 minutes of the spinning motion in bulk carrier.

Flow and Strength Properties of Cement Mortar Mixed with High Range Water Reducer Containing Carboxylic Acid (카르본산계 고성능감수제를 첨가한 시멘트 모르타르의 유동 특성)

  • 김화중;강인규;권영도;김우성;황재현;김원기;박기청
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.142-147
    • /
    • 1995
  • In this study, styrene-maleic anhydride copolymer (SMA) was synthesized from styrene and maleic anhydride and further reacted with sulfuric acid to obtain water-soluble SMA and the flow and strength tests of cement mortar mixed with copolymers were carried out to evaluate the capability of copolymers as high range water reducer for the concrete. It was found from flow experiment that the fluidity of cement mortar mixed with sulfonated SMA (SSMA) was larger than that miced with aminophenol-substituted SSMA (SmSMA). The decreasing rate of the flow of cement mortar mixed with SSMA and SmSMA was decreasing rate of the flow of cement mortar mixed with SSMA and SmSMA was significantly lower than that mixed with naphthalene condensate (NSC). The compressive strength of the hardened cement mortars containing 0.5% copolymers after 28 days curing was examined. The compressive strength of hardened cement mortar containing SSMA and SmSMA was increased up to 32% and 13%, respectively, when compared to the plain. As the results, the copolymers (SSMA and SmSMA) used in this study are greatly expected as a good high range water reducers for the concrete.

  • PDF

An Empirical Comparison and Verification Study on the Containerports Clustering Measurement Using K-Means and Hierarchical Clustering(Average Linkage Method Using Cross-Efficiency Metrics, and Ward Method) and Mixed Models (K-Means 군집모형과 계층적 군집(교차효율성 메트릭스에 의한 평균연결법, Ward법)모형 및 혼합모형을 이용한 컨테이너항만의 클러스터링 측정에 대한 실증적 비교 및 검증에 관한 연구)

  • Park, Ro-Kyung
    • Journal of Korea Port Economic Association
    • /
    • v.34 no.3
    • /
    • pp.17-52
    • /
    • 2018
  • The purpose of this paper is to measure the clustering change and analyze empirical results. Additionally, by using k-means, hierarchical, and mixed models on Asian container ports over the period 2006-2015, the study aims to form a cluster comprising Busan, Incheon, and Gwangyang ports. The models consider the number of cranes, depth, birth length, and total area as inputs and container twenty-foot equivalent units(TEU) as output. Following are the main empirical results. First, ranking order according to the increasing ratio during the 10 years analysis shows that the value for average linkage(AL), mixed ward, rule of thumb(RT)& elbow, ward, and mixed AL are 42.04% up, 35.01% up, 30.47%up, and 23.65% up, respectively. Second, according to the RT and elbow models, the three Korean ports can be clustered with Asian ports in the following manner: Busan Port(Hong Kong, Guangzhou, Qingdao, and Singapore), Incheon Port(Tokyo, Nagoya, Osaka, Manila, and Bangkok), and Gwangyang Port(Gungzhou, Ningbo, Qingdao, and Kasiung). Third, optimal clustering numbers are as follows: AL(6), Mixed Ward(5), RT&elbow(4), Ward(5), and Mixed AL(6). Fourth, empirical clustering results match with those of questionnaire-Busan Port(80%), Incheon Port(17%), and Gwangyang Port(50%). The policy implication is that related parties of Korean seaports should introduce port improvement plans like the benchmarking of clustered seaports.

Evaluation of Electromagnetic Shielding Performance of SiC and Graphite Mixed Mortar (SiC 및 흑연 혼입 모르타르의 전자파 차폐 성능 평가)

  • Park, Oh-Seong;Cho, Hyeong-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.459-468
    • /
    • 2021
  • Blocking electromagnetic waves on the exterior walls of buildings effectively reduces the intensity of electromagnetic fields in buildings, which leads to attenuation of electromagnetic disturbances, so there is a great interest in developing technologies. In this study, SiC by-products and graphite generated in the semiconductor field were selected and mixed into mortar after pretreatment such as pulverization to evaluate their physical properties and electromagnetic wave shielding performance. Considering the economic efficiency of each shielding material, only 10% volume of the outermost side of the experiment was mixed with each shielding material to evaluate the shielding performance. The shielding performance was predicted when the experiment was manufactured by mixing the shielding material with the entire volume of the experiment using the shielding effect evaluation formula. The results of the experiment showed that the shielding performance was up to 20 dB when SiC grains were mixed with shielding materials, the shielding performance was up to 18 dB when graphite powder was mixed with shielding materials, and the shielding performance was up to 28 dB when SiC powder was mixed with shielding materials, and the shielding performance was close to 30 dB, which is known to have a shielding rate of 99.9%.

Weighted zero-inflated Poisson mixed model with an application to Medicaid utilization data

  • Lee, Sang Mee;Karrison, Theodore;Nocon, Robert S.;Huang, Elbert
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.2
    • /
    • pp.173-184
    • /
    • 2018
  • In medical or public health research, it is common to encounter clustered or longitudinal count data that exhibit excess zeros. For example, health care utilization data often have a multi-modal distribution with excess zeroes as well as a multilevel structure where patients are nested within physicians and hospitals. To analyze this type of data, zero-inflated count models with mixed effects have been developed where a count response variable is assumed to be distributed as a mixture of a Poisson or negative binomial and a distribution with a point mass of zeros that include random effects. However, no study has considered a situation where data are also censored due to the finite nature of the observation period or follow-up. In this paper, we present a weighted version of zero-inflated Poisson model with random effects accounting for variable individual follow-up times. We suggested two different types of weight function. The performance of the proposed model is evaluated and compared to a standard zero-inflated mixed model through simulation studies. This approach is then applied to Medicaid data analysis.

A Structure of Personalized e-Learning System Using On/Off-line Mixed Estimations Based on Multiple-Choice Items

  • Oh, Yong-Sun
    • International Journal of Contents
    • /
    • v.5 no.1
    • /
    • pp.51-55
    • /
    • 2009
  • In this paper, we present a structure of personalized e-Learning system to study for a test formalized by uniform multiple-choice using on/off line mixed estimations as is the case of Driver :s License Test in Korea. Using the system a candidate can study toward the license through the Internet (and/or mobile instruments) within the personalized concept based on IRT(item response theory). The system accurately estimates user's ability parameter and dynamically offers optimal evaluation problems and learning contents according to the estimated ability so that the user can take possession of the license in shorter time. In order to establish the personalized e-Learning concepts, we build up 3 databases and 2 agents in this system. Content DB maintains learning contents for studying toward the license as the shape of objects separated by concept-unit. Item-bank DB manages items with their parameters such as difficulties, discriminations, and guessing factors, which are firmly related to the learning contents in Content DB through the concept of object parameters. User profile DB maintains users' status information, item responses, and ability parameters. With these DB formations, Interface agent processes user ID, password, status information, and various queries generated by learners. In addition, it hooks up user's item response with Selection & Feedback agent. On the other hand, Selection & Feedback agent offers problems and content objects according to the corresponding user's ability parameter, and re-estimates the ability parameter to activate dynamic personalized learning situation and so forth.

Vertical Distribution of Foraging Tits in Mixed Species Flocks in Urban Forests

  • Lee, Sang-Don
    • The Korean Journal of Ecology
    • /
    • v.22 no.2
    • /
    • pp.65-68
    • /
    • 1999
  • In December-January of 1996-1997 and 1997-1998, information was gathered about vertical distribution of foraging sites of tits in 34 flocks in coniferous and deciduous forests. There was a significant effect of forest type on the distribution of foraging sites of each species. Habitat was classified into 5 height layers vertically: ground, bushes (usually<1.5 m, up to 3 m), tree layer 1 (up to 1/3 of tree height), tree layer 2 (1/3-2/3 tree height). and tree layer 3 (>2/3 tree height). There were differences among species: great tit (Parus major) foraged mostly on the ground, coal tit (P. ater) and long-tailed tit (Acrocephalus caudatus) - on the highest tree layer, marsh tit (P. palustris) was often seen on bushes, and varied tit (P. varius) - in tree layer 2. Smaller species used upper and outer parts of trees. suggesting that, like in most other similar studies. larger dominant species prevented smaller species from using inner parts of trees.

  • PDF

On the Large Eddy Simulation of Scalar Transport with Prandtl Number up to 10 Using Dynamic Mixed Model

  • Na Yang
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.913-923
    • /
    • 2005
  • The dynamic mixed model (DMM) combined with a box filter of Zang et. al. (1993) has been generalized for passive scalar transport and applied to large eddy simulation of turbulent channel flows with Prandtl number up to 10. Results from a priori test showed that DMM is capable of predicting both subgrid-scale (SGS) scalar flux and dissipation rather accurately for the Prandtl numbers considered. This would suggest that the favorable feature of DMM, originally developed for the velocity field, works equally well for scalar transport problem. The validity of the DMM has also been tested a posteriori. The results of the large eddy simulation showed that DMM is superior to the dynamic Smagorinsky model in the prediction of scalar field and the model performance of DMM depends to a lesser degree on the ratio of test to grid filter widths, unlike in the a priori test.