Mitigation of Stray Current Interference from DC Electric Railroad(1) Domestic Conditions (직류전기철도의 누설전류 간섭대책(1) 국내 현황)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.270-272
    • /
    • 2005
  • With the wide spread of direct current (DC) electric railroads in Korea, the stray currents from negative return rails become a pending problem to the safety of nearby underground infrastructures, such as gas pipelines, water distribution lines, heat pipelines, POF cables, etc. The mitigation of such interference, however, is mainly dependent on stray current drainage bond methods, which connect the underground metallic structures to the negative feeder cables attached to the rails with diodes (polarized drainage) or thyristors (forced drainage). Despite some merits of these methods, they increase the total amount of stray currents from rails and cause other interference problems. In this paper, we summarize the domestic conditions of stray current interference and describe a conceptual design of other mitigation methods for such interference.

  • PDF

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

A Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA (국가 기간 시설물의 전식 대책(안))

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1609-1611
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) system of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. In this paper, the mechanism of mitigation method of DC stray current for underground metallic structures is described.

  • PDF

Field Test of Mitigation Methods for Stray Currents from DC Electric Railroad(2) Rapid Potential-Controlled Rectifier (직류전기철도 전식대책 실증실험(2) 속응형 정전위 정류기)

  • Ha, Yoon-Cheol;Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Jeong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.217-219
    • /
    • 2007
  • With the wide spread of direct current(DC) electric railroads in Korea, the stray current or leakage currents from negative return rails become a pending problem to the safety of nearby underground Infrastructures. The most widely used mitigation method for this interference is the stray current drainage method, which connects the underground metallic structures to the rails with diodes (polarized drainage) or thyristor (forced drainage). This method, however, inherently possesses some drawbacks such as an increase of total leakage torrents from rails, expansion of interference zone, etc. In order to resolve these drawbacks, we developed a rapid potential-controled rectifier and applied to a depot area where stray current inference is very severe. The effect of this method was analyzed from the field tell data and we suggest this method can be an excellent alternative to the drainage-bond-based mitigation methods.

  • PDF

Field Test of Mitigation Methods for Stray Currents from DC Electric Railroad(1) Stray Current Drainage System (직류전기철도 전식대책 실증실험(1) 누설전류 배류시스템)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Jeong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.220-222
    • /
    • 2007
  • With the wide spread of direct current (DC) electric railroads in Korea, the stray currents or leakage currents from negative return rails become a pending problem to the safety of nearby underground infrastructures. The most widely used mitigation method for this interference is the stray current drainage method, which connects the underground metallic structures to the rails with diodes (polarized drainage) or thyristor (forced drainage). Although this method inherently possesses some drawbacks, its cost effectiveness and efficiency to protect the interfered structures has been the main reason for the wide adoption. In this paper, we show the field test results for the application of stray current drainage system to a city gas pipeline paralleling a depot area of a metropolitan rapid transit system. The process for optimal positioning is briefly illustrated. The effectiveness of constant voltage, constant current, and constant potential drainage schemes was also described.

  • PDF

Mitigation of Stray Current Interference from DC Electric Railroad(2) DICCP System (직류전기철도의 누설전류 간섭대책(2) 분포외부전원시스템)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.273-275
    • /
    • 2005
  • The national need to establish a new stray current mitigation method to protect the underground metallic infrastructures in congested downtown area forced us to design and develop the distributed impressed current cathodic protection (DICCP) system. The main purpose of this system is to replace the stray current drainage bond methods, which is widely adopted by pipeline owners in Korea. Currently, forced drainage makes up about 85% of total drainage facilities installed in Korea because polarized drainage can neither drain perfectly the stray currents during normal operation of electric vehicle nor drain the reverse current during regenerative braking at all. The forced drainage, however, has been abused as an alternative cathodic protection system, which impresses currents from rails to the pipelines and accordingly uses the rails as anodes. As a result, it is necessary to consider a new method to both cathodically protect the pipelines and effectively drain the stray currents. In this paper, we describe the design parameters and installation schemes of DICCP system that can meet these demands.

  • PDF

Mitigation of Stray Current Interference from DC Electric Railroad(3) Stray Current Confinement Method (직류전기철도의 누설전류 간섭대책(3) 누설전류 포집시스템)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.276-278
    • /
    • 2005
  • For over 25 years, the stray currents from DC electric railroads have caused serious interference problems with underground metallic infrastructures in Korea. The most serious interference is reported at the pipelines near the depot areas. Our field survey proves that this phenomena is mainly due to the missing of dedicated rectifiers for mainline, depot and/or workshop areas. Because it takes so much time and costs too much to replace the traction power system, we consider a stray current confinement method which collects the stray currents and drains them to the negative terminal of the rectifier. This can be realized by installing a stray current collecting wire along the depot boundary. Moreover, we found the stray current collecting reinforcement bar located beneath the rails of concrete slab tracks. Using this bar, we arc going to draing the stray currents from mainline rails. In this paper we show the result of field survey on railroad facilities and present the stray current confinement method under field test.

  • PDF

A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA (국가기간시설물의 전식대책(안) 및 그 적용 사례(1))

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF

Analysis of DC Traction Stray Current Interference on Buried Pipelines (지하철 누설전류가 도시가스 배관에 미치는 영향 해석)

  • Lee H.G.;Ha T.H.;Ha Y.C.;Bae J.H.;Kim D.K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1376-1378
    • /
    • 2004
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the cathodic protection systems of buried pipelines and DC traction stray current influence on it using the simulation software CatPro. We can discuss the problems and mitigation of DC traction interference for protected pipeline.

  • PDF

Numerical Analysis of the Interference of the Buried Pipeline due to the Stray Current from the Parallel Electric Railway (전기철도와 평행한 매설배관에서 누설전류에 의한 간섭현상의 수치해석적 연구)

  • Jung, Chan-Oong;Choi, Kyu-Hyoung
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.8-13
    • /
    • 2008
  • The stray current interference problem could induce the corrosion of near-by structure and rail itself. Many efforts has been concentrated on the reduction of the interference. In this work the influences of separation distance, soil resistivity, pipe coating resistance, leak resistance of rail were studied using the numerical analysis methods. These analysis could be used to estimate the sensitivity of each variables in the study of the mitigation method and their numerical analysis.

  • PDF