• Title/Summary/Keyword: mitigate

Search Result 2,580, Processing Time 0.03 seconds

A MB-OFDM UWB 0.18-μm CMOS RF Front-End Receiver

  • Kim, Chang-Wan
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.34-39
    • /
    • 2008
  • An RF front-end dual-conversion receiver for $3{\sim}5\;GHz$ MB-OFDM UWB systems is implemented in $0.18\;{\mu}m$ CMOS technology. The receiver includes a two-stage UWB LNA, an RF mixer, an IF I/Q mixer, and a frequency synthesizer. The proposed receiver adopts the dual-conversion architecture to mitigate the burden of design of the frequency synthesizer. Accordingly, the proposed frequency synthesizer generates four LO tones from only one VCO. The receiver front-end achieves power gain of 16.3 to 21 dB, NF of 7 to 7.6 dB over $3{\sim}5\;GHz$, and IIP3 of -21 dBm, while consuming 190 mW from a 1.8 V supply.

A Study of the Active Resonance Damper for a DC Distributed Power System with Parallel Pulsed Power Loads (병렬펄스부하를 갖는 직류배전시스템을 위한 능동 공진 댐퍼에 대한 연구)

  • La, Jae-Du;Lee, Byung-Hun;Chang, Han-Sol;Woo, Hyun-Min;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1289-1295
    • /
    • 2012
  • An active resonance damper for a DC Distributed Power System(DPS) with parallel loads is presented. Each pulse power load in a DC DPS comprises both a resistive power load and a step-up converter. The step-up converter behave as constant power load(CPL) when tightly regulated and usually cause a negative impedance instability problem. Furthermore, when an input filter is connected to a large constant power load, the instability of DC bus voltage. In this paper, a bidirectional DC/DC converter with a reduced storage capacitor quantitatively are proposed as a active resonance damper, to mitigate the voltage instability on the bus. The validity of the proposed method was confirmed by simulation and experimental works.

Operation Scheme for a Wind Farm to Mitigate Output Power Variation

  • Lee, Sung-Eun;Won, Dong-Jun;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.869-875
    • /
    • 2012
  • Because of the nature of wind, the output power of wind turbines fluctuates according to wind speed variation. Therefore, many countries have set up wind-turbine interconnection standards usually named as Grid-Code to regulate the output power of wind farms to improve power system reliability and power quality. This paper proposes three operation modes of wind farms such as maximum power point tracking (MPPT) mode, single wind turbine control mode and wind farm control mode to control the output power of wind turbines as well as overall wind farms. This paper also proposes an operation scheme of wind farm to alleviate power fluctuation of wind farm by choosing the appropriate control mode and coordinating multiple wind turbines in consideration of grid conditions. The performance of the proposed scheme is verified via simulation studies in PSCAD/EMTDC with doubly-fed induction generator (DFIG) based wind turbine models.

A Phase-shifter for Regulating Circulating Power Flow in a Parallel-feeding AC Traction Power System

  • Choi, Kyu-Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1137-1144
    • /
    • 2014
  • A parallel-feeding AC traction power system increases the power supply capacity and decreases voltage fluctuations, but the circulating power flow caused by the phase difference between the traction substations prevents the system from being widely used. A circuit analysis shows that the circulating power flow increases almost linearly as the phase difference increases, which adds extra load to the system and results in increased power dissipation and load unbalance. In this paper, we suggest a phase shifter for the parallel-feeding AC traction power system. The phase shifter regulates the phase difference and the circulating power flow by injecting quadrature voltage which can be obtained directly from the Scott-connection transformer in the traction substation. A case study involving the phase shifter applied to the traction power system of a Korean high-speed rail system shows that a three-level phase shifter can prevent circulating power flow while the phase difference between substations increases up to 12 degrees, mitigate the load unbalance, and reduce power dissipation.

A Novel Journal Evaluation Metric that Adjusts the Impact Factors across Different Subject Categories

  • Pyo, Sujin;Lee, Woojin;Lee, Jaewook
    • Industrial Engineering and Management Systems
    • /
    • v.15 no.1
    • /
    • pp.99-109
    • /
    • 2016
  • During the last two decades, impact factor has been widely used as a journal evaluation metric that differentiates the influence of a specific journal compared with other journals. However, impact factor does not provide a reliable metric between journals in different subject categories. For example, higher impact factors are given to biology and general sciences than those assigned to other traditional engineering and social sciences. This study initially analyzes the trend of the time series of the impact factors of the journals listed in Journal Citation Reports during the last decade. This study then proposes new journal evaluation metrics that adjust the impact factors across different subject categories. The proposed metrics possibly provides a consistent measure to mitigate the differences in impact factors among subject categories. On the basis of experimental results, we recommend the most reliable and appropriate metric to evaluate journals that are less dependent on the characteristics of subject categories.

An Indoor Positioning Method using IEEE 802.11 Channel State Information

  • Escudero, Giovanni;Hwang, Jun Gyu;Park, Joon Goo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1286-1291
    • /
    • 2017
  • In this paper, we propose an indoor positioning system that makes use of the attenuation model for IEEE 802.11 Channel State Information (CSI) in order to determine its distance from an Access Point (AP) at a fixed position. With the use of CSI, we can mitigate the problems present in the use of Received Signal Strength Indicator (RSSI) data and increase the accuracy of the estimated mobile device's location. For the experiments we performed, we made use of the Intel 5300 Series Network Interface Card (NIC) in order to receive the channel frequency response. The Intel 5300 NIC differs from its counterparts in that it can obtain not only the RSSI but also the CSI between an access point and a mobile device. We can obtain the signal strengths and phases from subcarriers of a system which in turn means making use of this data in the estimation of a mobile device's position.

A Three-Phase Line-Interactive UPS System to Eliminate the Inrush Current Phenomenon during Switching-in of an Auxiliary Load while Powering the Main Load

  • Bukhari, Syed Sabir Hussain;Ayub, Muhammad;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1623-1630
    • /
    • 2018
  • Normally, various auxiliary loads are installed along with the main load in industrial applications. Usually, load transformers are used to convey such types of auxiliary loads. The transformers become energized when the loads are turned-on, consequently, high amplitude of inrush current appears at the output of the uninterrupted power supply (UPS) system. To mitigate these high current amplitudes, this manuscript suggests a three-phase line-interactive UPS system to counter the inrush current during the turning-on of the auxiliary load transformer while powering the main load by using a current controlled inverter. Experimental results of a laboratory-sized prototype are provided in the support of the proposed UPS system for validation.

Fuzzy Control Strategy for Damping Sub-Synchronous Resonance

  • Qader, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1791-1797
    • /
    • 2018
  • Sub-Synchronous Resonance (SSR) is a phenomenon that harms turbine generator shafts because the phenomenon induces sub-synchronous wavering in the system. In the study presented in this paper, a dynamic resistance bank is used to mitigate the occurrence of sub-synchronous phenomenon. A fuzzy logic controller using rotor speed deviation and its derivative as inputs is implemented to damp sub-synchronous oscillations more efficiently. An eigenvalue technique is used to analyse the stability of the system, and a simulation in MATLAB is conducted, based on the IEEE Second Benchmark, to validate the effectiveness of the proposed method under a 3-phase fault condition at an infinite bus. The time-domain simulation and eigenvalues are used to observe the proposed method's superior ability to damp sub-synchronous oscillation.

System Level ESD Analysis - A Comprehensive Review II on ESD Coupling Analysis Techniques

  • Yousaf, Jawad;Lee, Hosang;Nah, Wansoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2033-2044
    • /
    • 2018
  • This study presents states-of-the art overview of the system level electrostatic discharge (ESD) analysis and testing. After brief description of ESD compliance standards and ESD coupling mechanisms, the study provides an in-depth review and comparison of the various techniques for the system level ESD coupling analysis using time and frequency domain techniques, full wave electromagnetic modeling and hybrid modeling. The methods used for improving system level ESD testing using troubleshooting and determining the root causes of soft failures, the optimization of ESD testing and the countermeasures to mitigate ESD problems are also discussed.

Delayed Parallel Interference Cancellation for GPS C/A Code Receivers

  • Glennon, Eamonn P.;Bryant, Roderick C.;Dempster, Andrew G.
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.261-266
    • /
    • 2006
  • A number of different techniques are available to mitigate the problem of cross correlations caused by the limited dynamic range of the 10-bit Gold codes in the GPS C/A code. These techniques include successive-interference cancellation (SIC) and parallel-interference cancellation (PIC), where the strong signals are subtracted at IF prior to attempting to detect the weak signals. In this paper, a variation of these techniques is proposed whereby the subtraction process is delayed until after the correlation process, although still employing a pure reconstructed C/A code signal to permit prediction of the cross correlation process. The paper provides details on the method as well as showing the results obtained when the method was implemented using a software GPS receiver. The benefits of this approach are also described, as is the application of the method to the cancellation of CW interference.

  • PDF