A Development of Image Transfer Remote Maintenance Monitoring System for Hand Held Device (휴대용 화상전송 원격정비 감시시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.276-284
    • /
    • 2009
  • In this paper, we develop the image transfer remote maintenance monitoring system for hand held device which can compensate defects of human mistake. The human mistakes always happen when the worker communicate information each other to check and maintenance the equipment of the power plant under bad circumstance such as small place and long distance in power plant. A worker couldn't converse with other when in noisy place like Power plant. So, we make some hand device for handy size and able to converse in noisy place. The developed system can have improvement of productivity through increasing plant operation time. And developed system is composed of advanced H/W(hard ware) system and S/W(soft ware)system. The H/W system consist of media server unit, communication equipment with hand held device, portable camera, mike and head set. The advanced s/w system consist of data base system, client pc(personal computer) real time monitoring system which has server GUI(graphic user interface) program, wireless monitoring program and wire ethernet communication program. The client GUI program is composed of total solution program as pc camera program, and phonetic conversation program etc.. We analyzed the required items and investigated applicable part in the image transfer remote maintenance monitoring system with hand held device. Also we investigated linkage of communication protocol for developed prototype, developed software tool of two-way communication and realtime recording skill of voice with image. We confirmed the efficiency by the field test in preventive maintenance of plant power.

The Automatical Process Map Generation Using Network Representation In Radiopharmaceutical Synthesis (네트워크 모델링을 통한 방사성의약품 합성 프로세스 맵 자동생성 시스템)

  • Lee, Cheol-Soo;Heo, Eun-Young;Kim, Jong-Min;Kim, Dong-Soo
    • IE interfaces
    • /
    • v.24 no.2
    • /
    • pp.156-163
    • /
    • 2011
  • The radiopharmaceutical synthesis for PET (positron emission tomography) is composed of chemical reactions using automated synthetical equipment. Due to the radioactive material, the automated equipment is being frequently developed to replace human operators who conduct dangerous, repetitive and dexterous operations. As to operation, the manipulating program is commonly coded using the spread sheet while the whole actuators are mapped in every step. The process map (program) is changed according to such parameters as temperature of reactor, keeping time, mixture sequence and amount of reagent. In cases of customizing the automated synthetical equipment or developing the new radiopharmaceuticals, lots of experiments should be conducted and the programming mistake is not allowed as it can lead abnormal control of the equipment to leak the radioactive materials. The exact process map has depended on trial and error manner. Thus, this study developed the methodology to tabulate the synthetical process to convert the process map automatically while the synthetical module formation is represented by a network model. The proposed method is validated using the actual radiopharmaceutical synthetical procedure.

Determination of Air Fuel Ratio According to Fuel Composition (II) -Compensation of Unburned Gas Concentration in Eltinge Chart- (연료 조성에 따른 공연비 산정 (II) -Eltinge 차트에서 미연 성분의 보상-)

  • Ohm, In-Yong;Park, Chan-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.11
    • /
    • pp.1563-1571
    • /
    • 2003
  • This paper is the second part of several companion papers which compare the method of Air-fuel ratio(AFR) determination. In the previous paper, Eltinge chart was applied to the arbitrary fuel composition and the charts for gasoline, diesel, methanol, M85, liquefied petroleum gas(LPG), natural gas(NG), propane and butane were illustrated. In Eltinge chart, however, unburned hydrocarbon (UHC) is not used for determination of AFR. For improving accuracy, Eltinge suggested UHC compensation after the AFR reading in the chart. This compensation reduced the difference between real and reading value. In the compensation, however, the correction of oxygen and carbon dioxide is uncertain and there might be a mistake in conversion of UHC reading value. Therefore, the error is overestimated comparing with Spindt one which is most widely used. In addition, there is no comparison of the value with other useful methods. In this paper, the compensation of unburned HC was performed in Eltinge chart and the compensated value was compared with Spindts formula over wide range of AFR. The objects of investigating fuel are gasoline, methanol, NG and LPG. The result shows that Eltinge and Spindt method is flawlessly compatible and the difference between the two methods is under 0.3% in a λrange from 0.9 to 1.7. The method fur debugging instrumentation error is also presented.

A Study on Safety Accidents Occurred for 5 Years at a Welding Material Manufacturing Factory (모 금속 제조 업체에서 5년간 발생한 안전사고에 관한 조사)

  • Lim, Hyun-Sul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.3 s.51
    • /
    • pp.551-562
    • /
    • 1995
  • To assess the status of safety accidents, authors reviewed and analysed the records of safety accidents of a welding material manufacturing factory at Pohang city from January 1989 to December 1993. The results are; 1. The total incidence of safety accidents was 295 spells for five years. 2. Average age of workers with accident was 35.7 years. Average duration of employment was 6.2 years and the duration of employment increased as the year increased. 3. There was no statistical significance on season, month, weekday and time by year in the incidence of safety accidents. The most frequent part of body injured was upper extremities and the most frequent type of injury was abrasion. 4. Mean admission rate of safety accidents was 12.6% and the ratio of treated spells as occupational injury was 7.8%. 5. The most frequent cause of injury was worker's mistake and the most frequent action for the prevention of further accidents was safety education. 6. The incidence rate of safety accidents on 1993 was 116.2 spells per 1,000 persons. Above results suggest that to prevent safety accidents, safety education should be done continuously, the environmental and human factors were controlled and more exact reporting system of safety accidents was needed.

  • PDF

Principal Component Analysis of Marine Engine Troubles (선박기관사고의 주성분분석)

  • 윤석훈
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.1
    • /
    • pp.25-29
    • /
    • 1987
  • The engine room of ship is a synthetic system being composed of many machineries. Therefore, the reliability and safety of the all system of machinery is as important as each machine. In this paper, in order to reudce engine troubles while operation and to contribute in developing a high reliable marine engine the author analysed the factors of marine engine troubles by principal com-ponent analysis method. Analysed data are marine engine troubles of sea casualties from 1980 to 1985. It is found that the major part of marine engine troubles resulted from personal mistake, and also the troubles of shaft, propeller and cylinder occupied considerable proportion.

  • PDF

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

Review of Legislation Case in Main Country about the Validity of International Commercial Contract (국제상사계약의 유효성에 관한 주요국가의 입법례 검토)

  • RYU, Chang-Won
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.69
    • /
    • pp.153-178
    • /
    • 2016
  • The United Nations Convention on the International Sale of Goods(CISG) leaves a number of aspects concerning commercial sales untouched. In particular, it is not concerned with the validity of the contract or of any of its provisions or of any usage. And UNIDROIT don't deal with all-round validity in International Commercial Contract. Especially, UNIDROIT includes declaration of intention department. The UNIDROIT contains the chapter 3 on the "validity" in terms of the defects of consent such as mistake, fraud, and threat as well as "gross disparity". Notwithstanding these provisions, the Principles did not deal with invalidity arising from the lack of capacity or authority, or immorality or illegality. On the other hand, there are arguments that the corresponding provisions of the Principles of International Commercial Contracts(UNIDROIT Principles; PICC). Therefore, Validity in International Commercial Contract is delegate by Each Country Law. So Trade practicer should know full well about Each Country Law Position. People(human, corporation, company) of position Trade practice classify each country civil law relation to validity of commercial contract. This paper is to examine the Validity of UNIDROIT Principles. Also this paper analyses comparison on each country position relation to capacity of right, capacity to act, illegality of contract, declaration of intention. In conclusion, This paper expect that people of trade practice makes use of analysis knowledge.

  • PDF

Structural behaviour under wind loading of a 90 m steel chimney

  • Tranvik, Par;Alpsten, Goran
    • Wind and Structures
    • /
    • v.8 no.1
    • /
    • pp.61-78
    • /
    • 2005
  • This paper presents results from an investigation of the structural behaviour of a very slender 90 m high steel chimney erected at V$\ddot{a}$xj$\ddot{o}$ in southern Sweden in 1995. The chimney is equipped with a mechanical friction-type damper at the top. Due to a mistake during erection and installation of the chimney the transport fixings of the damper were not released properly and the chimney developed extensive oscillations in the very first period of service. This caused a great number of fatigue cracks to occur within a few months of service. After the functioning of the damper had been restored and the fatigue cracks were repaired an extensive program was initiated in 1996 to monitor the structural behaviour of the chimney under wind loading. In the investigation data were collected for more than six years of continuous measurements and regular observations of the chimney. The data obtained have some general relevance with respect to wind data, behaviour of a slender structure under wind loading, and the effect of a mechanical damper. Also some theoretical studies were performed as part of the investigation of the chimney.

The Relationship between Workers' Safety Behaviors and Safety Climate in Chemical Industry (화학산업 작업자의 안전행동과 안전분위기의 상관관계)

  • Baek, Jong-bae;Uhm, Minyong;Kim, Ji-sun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.100-107
    • /
    • 2015
  • Korea government has established and enforced countermeasures about the various policy of industrial accident prevention. Recent chemical accidents included hazardous materials. Exposure to these chemicals can cause serious environmental poisoning and various health problems. The key factor causing these major accidents may be associated with the mistake in workers' safety behaviors. Some researchers noted workers' safety behaviors may be related to workers' safety climate. In this research, a survey was conducted to explore workers' safety behaviors and safety climate in a large petrochemical company in Korea. The company processes major petrochemical materials and any spills can be hazardous and cause chemical disasters. In this study, we explored one petrochemical company to investigate three hypotheses. 593 workers were surveyed for this study. We checked association between workers' safety behavior and safety climate. The survey result shows the people who have safety climate do safe behavior.

A Centralized Monitoring System for Factory Electrical Installation Using Active Database (능동 데이터베이스를 이용한 중앙전력감시시스템)

  • Choi, Sang-Yule;Moon, Hyun-Ho;Lee, Jong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.115-122
    • /
    • 2010
  • The main purpose of centralized monitoring system is to manage factory electrical installation efficiently by on-line data acquisition and supervisory control. The existing centralized system is only able to be managed by operator whenever electrical installation's faults are detected. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a centralized monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.