• Title/Summary/Keyword: mirror condition

Search Result 131, Processing Time 0.025 seconds

Optimal Conditions for Mist Sensing and Removal in Automobile (자동차 내부의 김서림 감지 및 제거를 위한 최적의 조건)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.763-769
    • /
    • 2012
  • For mist sensing, temperature-humidity sensor is attached on six positions of front glass and rearview mirror in automobile. Bottom-left side of front glass is the best position where mist is sensing. For mist removal, air conditioner is turned on intensity 1, 3 and is set the temperature at 17[$^{\circ}C$], 25[$^{\circ}C$]. And heater is turned on intensity 1, 3 and is set the temperature at 25[$^{\circ}C$], 32[$^{\circ}C$]. The best condition which mist is removed is temperature at 17[$^{\circ}C$] and intensity 3 of air conditioner mode. At this condition, total average value of humidity output voltage difference is 0.561[V]. Also, air conditioner mode is effective than heater mode for mist sensing and removal.

Fabrication of $TiO_{2}$ In-line Reflection Mirror and Its Characteristics for Fiber Optic Fabry-Perot Interferometric Sensor (광섬유 Fabry-Perot 간섭형 센서 제조를 위한 $TiO_{2}$ 반사막의 형성 및 그 특성)

  • Park, Dong-Soo;Kim, Myung-Gyoo;Kim, Chang-Won;Lee, Jung-Hee;Kang, Shin-Won;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.71-79
    • /
    • 1995
  • For the fabrication of high sensitive intrinsic fiber optic Fabry-Perot interferometeric sensor, the deposition conditions of $TiO_{2}$ thin film used to the internal mirrors of the sensor were investigated. The $TiO_{2}$ film deposited by RF magnetron sputter had higher refractive index ($2.36{\sim}2.48$) and better stoiciometry (O/Ti = 2) than that deposited bye-beam evaporator. In the case of forming $TiO_{2}$ internal mirror by using fusion splicing technique, the $TiO_{2}$ reflection mirror deposited by RF magnetron sputter in the condition of 120W RF power showed high. reflectance and excellent controllability of reflection power. The fabricated intrinsic fiber optic Fabry-Perot interferometer with two $TiO_{2}$ internal mirrors deposited under the condition showed very stable fringe patterns. It is, therefore, expected that the interferometer will be applicable to various high precision sensors.

  • PDF

Response of Electrocardiogram of Mirror Carp, Cyprinus carpio to Light Stimuli (광 자극에 대한 향어의 심전도)

  • 양용림;김영기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.124-132
    • /
    • 2001
  • The authors examined the response of electrocardiogram (ECG) of Mirror carp, Cyprinus carpio [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli (10, 100, and 400 lux) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes. The results which are divided into by day and by night and then analyzed by fishes conditions are as follows : 1. Mirror carps reached a stable condition 5 minutes after anesthesia. In this condition, the average heart rate was 64.9 beat/min by day and 65.3 beat/min by night. And the average action potential was 36.9 nV by day and 32.9 nV by night. 2. The average heart rate by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 68.7 beat/min by day and 46.0 beat/min by night, in case of 100 lux 53.4 beat/min by day and 44.1 beat/min by night, and in case of 400 lux 53.2 beat/min by day and 40.1 beat/min by night. 2) In a recovery condition, in case of 10 lux 67.9 beat/min by day and 57.2 beat/min by night, in case of 100 lux 68.8 beat/min by day and 61.0 beat/min by night, and in case of 400 lux 69.6 beat/min by day and 63.6 beat/min by night. 3. The average action potential by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 59.1 nV by day and 24.0 nV by night, in case of 100 lux 26.8 nV by day and 45.6 nV by night, and in case of 400 lux 71.7 nV by day and 14.4 nV by night. 2) In a recovery condition, in case of 10 lux 38.8 nV by day and 27.3 nV by night, in case of 100 lux 29.0 nV by day and 39.3 nV by night, and in case of 400 lux 66.4 nV by day and 21.4 nV by night.

  • PDF

Cutting Characteristics of Oxygen-Free Using the Ultra Precision Machining (초정밀가공기를 이용한 무산소동 절삭특성)

  • 고준빈;김건희;원종호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.120-126
    • /
    • 2002
  • The needs of ultra-precisely machined parts are increasing more and more. But the experimental data required to ultra precision machining of nonferrous metal is insufficient. The behavior of cutting in micro cutting area is different from that of traditional cutting because of the size effect. Copper is widely used as optical parts such as LASER reflector's mirror and multimedia instrument. In experimental, after oxygen-free copper is machined by ultra precision machine with natural mono crystal diamond tool (NCD) and synthetic poly crystal diamond tool (PCD), we compared chip formation and tool's wear according to used tool. Also, we researched optimized cutting condition with the results measured according to cutting condition such as spindle speed, feed rate and depth of cut. As a result, the optimal working condition that makes good surface roughness is obtained. The surface roughness is good when spindle speed is above 80 m/min, and feed rate is small and depth of cut is above 0.5 ${\mu}{\textrm}{m}$. In cutting of klystron anode and cavity 3.2 nmRa of surface roughness is obtained.

The Effect of Action Observational Physical Training on Manual Dexterity in Stroke Patients (동작관찰훈련이 뇌졸중 환자의 손 조작능력에 미치는 영향)

  • Kim, Jong-Man;Yang, Byoung-Il;Lee, Moon-Kyu
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.17-24
    • /
    • 2010
  • The aim of this study was to determine the effect of action observational physical training (AOPT) on manual dexterity and corticomotor facilitation in stroke patients. Ten hemiparetic patients participated in this study. Each subject was asked to participate the three conditions; base condition (Base), physical training (PT), AOPT. Participants were asked to observe the action in the video that a therapist moved the blocks during the AOPT conditions. Corticomotor facilitation was determined in three conditions by monitoring changes in the amplitude of motor-evoked potentials (MEPs) elicited in hand muscles by transcranial magnetic stimulation. MEP responses were measured from the first dorsal interosseous after participants attended to three conditions. For the manual dexterity, Box and Block test (BBT) was used. The results of present study were summarized as follows: MEPs amplitude significantly tended to be larger than PT and Base condition. The scores of BBT in the AOPT condition were also significantly larger than other conditions. In conclusion, this finding of present study indicates that physical training for observation of an action is beneficial for enhancing a dexterity of paretic arm in stroke patients.

A Study on the Optimal Machining of 12 inch Wafer Polishing by Taguchi Method (다구찌 방법에 의한 12인치 웨이퍼 폴리싱의 가공특성에 관한 연구)

  • Choi, Woong-Kirl;Choi, Seung-Gun;Shin, Hyun-Jung;Lee, Eun-Sang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.48-54
    • /
    • 2012
  • In recent years, developments in the semiconductor and electronic industries have brought a rapid increase in the use of large size silicon. However, for many companies, it is hard to produce 400mm or 450mm wafers, because of excesive funds for exchange the equipments. Therefore, it is necessary to investigate 300mm wafer to obtain a better efficiency and a good property rate. Polishing is one of the important methods in manufacturing of Si wafers and in thinning of completed device wafers. This research investigated the surface characteristics that apply variable machining conditions and Taguchi Method was used to obtain more flexible and optimal condition. In this study, the machining conditions have head speed, oscillation speed and polishing time. By using optimum condition, it achieves a ultra precision mirror like surface.

Design and Fabrication of Sputter Coating System for Ophthalmic Lens (안경렌즈코팅용 소형 Sputter Coating System 설계 및 제작에 관한 연구)

  • Park, Moonchan;Jung, Boo Young;Kim, Eung Sun;Lee, Jong Geun;Joo, Kyung Bok;Moon, Hee Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • Purpose: To design and fabricate the small sputter coating system for the Ophthalmic lens. Methods: The design of sputter target was done using macleod program for AR coating and mirror coating of Ophthalmic lens with Si target and then the sputter system was fabricated. Results: The optimum condition of AR coating with Si target was [air|$SiO_2$(81.3)|$Si_3N_4$ (102)|$SiO_2$(19.21)|$Si_3N_4$(15.95)|$SiO_2$(102)|glass], for blue color mirror coating [air|$SiO_2$(56.61)|$Si_3N_4$(135.86)|$SiO_2$(67.64)|$Si_3N_4$(55.4)|$SiO_2$(53.53)|$Si_3N_4$(51.28)|glass], for green color coating [air|$SiO_2$(66.2)|$Si_3N_4$(22.76)|$SiO_2$(56.58)|$Si_3N_4$(140.35)|$SiO_2$(152.35)|$Si_3N_4$(70.16)|$SiO_2$(121.87)|glass], for gold color [air|$SiO_2$(83.59)|$Si_3N_4$(144.86)|$SiO_2$(11.82)|$Si_3N_4$(129.93)|$SiO_2$(90.01)|$Si_3N_4$(88.37)|glass]. Conclusions: In the fabrication of sputtering coating apparatus, Dual cathode with same Ti target were coated at the same time on both sides of Ophthalmic lens to lessen the time of coating on Ophthalmic Lens and save the cost of the lens. The distance of target-substrate of cathode was variable from 12.5 cm to 20 cm. Turbo pump was used to take the whole coating process about 15 min. instead of diffusion pump. The lens holder was made to coat 2 pairs lens every coating and was rotated to get the uniformity of thin film.

  • PDF

Detection of Elastic Waves Using Stabilized Michelson Interferometer (광로차 보상회로가 부착된 마이켈슨 간섭계에 의한 탄성파 신호검출)

  • Kim, Y.H.;So, C.H.;Kwon, O.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.4
    • /
    • pp.32-41
    • /
    • 1994
  • The stabilized Michelson interferometer was developed in order to measure micro dynamic displacement at the surface of solids due to elastic wave propagation. The stabilizer was designed to compensate light path disturbances using a reference mirror driven by piezoelectric actuator. Using stabilizer, the effect of external vibration was reduced and the quadrature condition was satisifed. As the results, the output of photodetector had maximum sensitivity and linearity. The minimum detectable displacement was 0.3nm at the band width of 10 MHz. The epicentral displacements due to the glass capillary breaks and the steel ball drop impact were measured using the developed interferometer and the results were compared with the calculated one.

  • PDF

Study on Ultra-Precision Grinding Condition of WC-Co (금형용 WC-Co의 초정밀 연삭 가공 조건에 관한 연구)

  • S.J. Heo;J.H. Kang;W.I. KIm
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.42-51
    • /
    • 1993
  • Recently, WC-Co have some excellent properities as the material for the mechanical component such as metallic moulding parts, ball dies parts, and punch parts. This paper describes the surface roughness and grinding force caused by experimental study on the surface grinding of WC-Co with ultra-precision like a mirror shape using diamond wheel. Also, some investigations are carried out using WA grinding wheel to increase improved ground surface roughness such as polishing, lapping effect. Some important results obtained here are summarized as follow. 1) Within this experimental grinding condition, we can be obtained $R_{max}.\;2\mu\textrm{m}\;R_a\;0.3\mu\textrm{m}$ whichare the most favourable ground surface roughness using #140 diamond wheel, and improved surface roughness values about 20 .approx. 25% throughout 5 times sparkout grinding 2) The value of surface roughness is Rmax. $0.49\mu\textrm{m},\;R_a\;0.06\mu\textrm{m}$ using #600 diamond wheel. 3) The area of no rack zone is less than $F_{n}$ 0.27N/mm, Ft 0.009N/mm

  • PDF

The Development of a Tongue Diagnosis System and the Evaluation of Reproducibility (설진 시스템 개발 및 재현성 평가)

  • Jeon, Young-Ju;Kim, Keun-Ho;Do, Jun-Hyeong;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.97-102
    • /
    • 2008
  • The tongue diagnosis is a diagnostic method in the oriental medicine that uses shape, substance, coating, and movement of the tongue to determine the condition of health and disease characteristics in human. Since this information, however, could be affected by subjective sense and visual information, it is difficult to obtain the objective and reproducible results. This research aims at building a reproducible tongue diagnosis system using color chart that is attached close to the face contact region. The picture of color chart is taken simultaneously with a tongue and applied to color revision. The system, in addition, is focused on providing a clear tongue image through securing a sufficient photographing distance with a surface coating mirror. The lightning part which can suppress the reflection by sputum in maximum is implemented for the objectification and quantification of the tongue diagnosis system. The face contact region is designed for consideration of a testee's convenience. To evaluate the reproducibility of the system, the CVs (coefficient of variance, %) of $L{\ast}$, $a{\ast}$ and $b{\ast}$ of red, green and blue regions in color chart are calculated, respectively. The results of all CVs shows that the tongue diagnosis system is re liable and those consequences contribute to the objectification and quantification of the tongue diagnosis system.

  • PDF