• Title/Summary/Keyword: minimum resolution

Search Result 370, Processing Time 0.021 seconds

High Resolution Linear Graphs : Graphical Aids for Designing Off-Line Process Control)

  • Lee, Sang-Heon
    • Journal of the military operations research society of Korea
    • /
    • v.27 no.1
    • /
    • pp.73-88
    • /
    • 2001
  • Designing high quality products and processes at a low cost is central technological and economic challenge to the engineer. The combination of engineering concepts and statistical implementations offered by Taguchi\`s off-line design technique has proven t be invaluable. By examining some deficiencies in designs from the Taguchi\`s highly fractional, orthogonal main effect plan based on orthogonal arrays, alternative method is proposed. The maximum resolution or the minimum aberration criterion is commonly used for selecting 2$^{n-m}$ fractional designs. We present new high resolution (low aberration) linear graphs to simplify the complexity of selecting designs with desirable statistical properties. The new linear graphs approach shows a substantial improvement over Taguchi\`s linear graphs and other related graphical methods for planning experiment. The new set of linear graphs will allow the experimenter to maintain the simple approach suggested by Taguchi while obtaining the best statistical properties of the resulting design such as minimum aberration as a by-product without dependency on complicated computational algorithm or additional statistical training.g.

  • PDF

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Minimum Temperature Mapping in Complex Terrain Considering Cold Air Drainage (냉기침강효과를 고려한 복잡지형의 최저기온 분포 추정)

  • 정유란;서형호;황규홍;황범석;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.3
    • /
    • pp.133-140
    • /
    • 2002
  • Site-specific minimum temperature forecasts are critical in a short-term decision making procedure for preventive measures as well as a long-term strategy such as site selection in fruits industry. Nocturnal cold air pools frequently termed in mountainous areas under anticyclonic systems are very dangerous to the flowering buds in spring over Korea, but the spatial resolution to detect them exceeds the current weather forecast scale. To supplement the insufficient spatial resolution of official forecasts, we developed a GIS - assisted frost risk assesment scheme for using in mountainous areas. Daily minimum temperature data were obtained from 6 sites located in a 2.1 by 2.1 km area with complex topography near the southern edge of Sobaek mountains during radiative cooling nights in spring 2001. A digital elevation model with a 10 m spatial resolution was prepared for the entire study area and the cold air inflow was simulated for each grid cell by counting the number of surrounding cells coming into the processing cell. Primitive temperature surfaces were prepared for the corresponding dates by interpolating the Korea Meteorological Administration's automated observational data with the lapse rate correction. The cell temperature values corresponding to the 6 observation sites were extracted from the primitive temperature surface, and subtracted from the observed values to obtain the estimation error. The errors were regressed to the flow accumulation at the corresponding cells, delineating a statistically significant relationship. When we applied this relationship to the primitive temperature surfaces of frost nights during April 2002, there was a good agreement with the observations, showing a feasibility of site-specific frost warning system development in mountainous areas.

The design of a scintillation system based on SiPMs integrated with gain correction functionality

  • Lin, Zhenhua;Hautefeuille, Benoit;Jung, Sung-Hee;Moon, Jinho;Park, Jang-Guen
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.164-169
    • /
    • 2020
  • Use of SiPM has been considered as an alternative to PMT, because of its compact size, low-operating voltage, non-sensitive to electromagnetic, low costs and so on. The main limitation for the use of SiPM is due to its small sensitive area compared to PMT that limits the light collection, and therefore the sensor energy resolution. In this article we studied the effect of increasing the number of SiPM by connecting them in parallel to increase the active detection area. This allowed us to compare the different energy resolution measurements. 137Cs has been selected as reference to study the energy resolution for 662 keV gamma-rays. Another investigation was to compare the minimum detectable gamma energy under various SiPM configurations. It has been found that the use of 4 SiPM arrays can greatly improve the energy resolution up to 4% than only one SiPM array, meanwhile use of more than 2 SiPM arrays does not increase the energy resolution significantly. Thus we can conclude that for a large area of cylindrical scintillator (3 × 3 inches), the use of SiPMs are limited to a certain number or certai active area depending on the commercial SiPMs, and its cost should be less than traditional PMT for the cost-effective and compact size considerations. It is well known that the gain of SiPM varies with temperature. In this article, we also calibrated gain to guarantee the same position of photoelectric peak in response of different temperatures.

A study on the resolution of the laser range finder (레이저 거리계의 분해능에 관한 연구)

  • Cha, Yeong-Yeop;Yu, Chang-Mok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.1
    • /
    • pp.82-87
    • /
    • 1998
  • In this study, the theoretical resolution analysis of an active vision system using laser range finder is performed for surrounding recognition and 3D data acquisition in unknown environment. In the result, the resolution of range data in laser range finder is depend on the distance between lens center of CCD camera and light emitter, view angle, beam angle, and parameters of CCD camera. The theoretical resolutions of the laser range finders of various types which are based on parameters effected resolution are calculated and experimental results are obtained in real system.

  • PDF

Visualization of Local Climates Based on Geospatial Climatology (공간기후모형을 이용한 농업기상정보 생산)

  • Yun Jin Il
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.4
    • /
    • pp.272-289
    • /
    • 2004
  • The spatial resolution of local weather and climate information for agronomic practices exceeds the current weather service scale. To supplement the insufficient spatial resolution of official forecasts and observations, gridded climate data are frequently generated. Most ecological models can be run using gridded climate data to produce ecosystem responses at landscape scales. In this lecture, state of the art techniques derived from geospatial climatology, which can generate gridded climate data by spatially interpolating point observations at synoptic weather stations, will be introduced. Removal of the urban effects embedded in the interpolated surfaces of daily minimum temperature, incorporation of local geographic potential for cold air accumulation into the minimum temperature interpolation scheme, and solar irradiance correction for daytime hourly temperature estimation are presented. Some experiences obtained from their application to real landscapes will be described.

Estimation of High Resolution Gridded Temperature Using GIS and PRISM (GIS와 PRISM을 이용한 고해상도 격자형 기온자료 추정)

  • Hong, Ki-Ok;Suh, Myoung-Seok;Rha, Deuk-Kyun;Chang, Dong-Ho;Kim, Chansoo;Kim, Maeng-Ki
    • Atmosphere
    • /
    • v.17 no.3
    • /
    • pp.255-268
    • /
    • 2007
  • This study generated and evaluated the high resolution (5 km) gridded data of monthly mean, maximum and minimum temperature from 2002 to 2005 over South Korea using a modified PRISM(Parameter-elevation Regressions on Independent Slopes Model: K-PRISM) developed by Daly et al. (2003). The performance of K-PRISM was evaluated by qualitative and quantitative ways using the observations and gridded data derived by inverse distance weighting (IDW) and hypsometric methods (HYPS). For the generation of high resolution gridded data, geographic informations over South Korea, such as the digital elevation, topographic facet and coastal proximity, are derived from the 1 km digital elevation data. The spatial patterns of temperature derived by K-PRISM were more closely linked to topography and coastal proximity than those by IDW. The K-PRISM performed much better than IDW for all months and temperatures, but it was equal to or slightly better than the HYPS. And the performances of K-PRISM were better in the minimum and mean temperature (winter) than the in maximum temperature (summer).

SUBMICRON TECHNOLOGY OF SINGLE LAYER PHOTO-RESIT (단층RESIST의 미세패턴형성기술)

  • Bae, Kyung-Sung;Hong, Seung-Kag
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.315-318
    • /
    • 1988
  • THE STUDY ABOUT CHARACTERISTICS OF PHOTO RESIST ITSELF (MINIMUM RESOLUTION, DEPTH OF FOCUS MARGIN AND CRITICAL DIMENSION CONTROL LATITUDE) WAS DONE AND REPORTED. THREE TYPES OF PHOTO RESISTS WERE TESTED. THE FIRST IS THE LOW MOLECULAR WEIGHT PHOTO-RESIST SHOWING THE NARROW DISTRIBUTION OF MOLECULAR WEIGHT (LOW MOLECULAR WEIGHT CONTROL TYPE), THE SECOND IS A PHOTO-RESIST CONTAINING THE INNER CONTRAST ENCHANCEMENT MATERIAL (INNER CEM TYPE) AND THE THIRD IS A NORMAL PHOTO-RESIST (HIGH MOLECULAR WEIGHT TYPE). THE INNER CEM TYPE AND THE LOW MOLECULAR WEIGHT CONTROL TYPE PHOTO-RESIST ARE MORE IMPROVED PHOTO-RESISTS. IT PROVED THAT THE MINIMUM RESOLUTION WAS IMPROVED BY 0.2 - 0.3 um, THE DEPTH OF FOCUS MARGIN WAS IMPROVED BY 0.8 - 1.2 um AND THE C.D. CONTROL LATITUIDE WAS IMPROVED.

  • PDF

Ferroelastic Domain and Refractive Property of $Gd_{2}(MoO_{4})_{3}$ Single Crystal ($Gd_{2}(MoO_{4})_{3}$ 단결정의 강탄성구역과 굴절률특성)

  • Son, Jong-Yoon;Lee, Chan-Ku;Lee, Su-Dae;Kim, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.98-102
    • /
    • 2002
  • We investigated domains and conoscope under the polarizing microscope and the index of refraction on the c-plate GMO which has the ferroelectric and ferroelastic phase at room temperature. To observed the change of refractive index in connection with domain, we developed an apparatus to obtain the refractive index by measuring the Brewster's angle. The resolution of the minimum rotation angle of this apparatus is $0.001^{\circ}$. To obtain the refractive index map on the sample, the moving distance of XY stage loaded sample holder is 60 mm and the minimum moving distance is 0.002 mm. Also, To obtain the indicatrix for single crystal, vertical turntable with sample holder and XY stage was loading on horizontal turntable. The minimum resolution angle of this vertical turntable is $0.001^{\circ}$. We measured the refractive index of transparent materials such as ferroelectrics. In the case of $Gd_{2}(MoO_{4})_{3}$, the Brewster angle is $62.11^{\circ}$ and then, the refractive index is 1.8895 by using He-Ne Laser. Also the refractive distribution of c-plate GMO was obtained with $400{\mu}m{\times}120{\mu}m$.

  • PDF