• Title/Summary/Keyword: microwave Oven

Search Result 327, Processing Time 0.025 seconds

Current Source ZCS PFM DC-DC Converter for Magnetron Power Supply

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.20-28
    • /
    • 2009
  • This paper presents the design of zero current switching ZCS pulse frequency modulation type DC-DC converter for magnetron power supply. A magnetron serving as the microwave source in a microwave oven is driven by a switch mode power supply (SMPS). SMPSs have the advantages of improved efficiency, reduced size and weight, regulation and the ability to operate directly from the converter DC bus. The demands of the load system and the design of the power supply required to produce constant power at 4[kV]. A magnetron power supply requires the ability to limit the load current under short circuit conditions. The current source series resonant converter is a circuit configuration which can achieve this. The main features of the proposed converter are an inherent protection against a short circuit at the output, a high voltage gain and zero current switching over a large range of output power. These characteristics make it a viable choice for the implementation of a high voltage magnetron power supply.

Development and Analysis of the Magnetron Analysis Program (마그네트론 전용 해석 프로그램의 개발과 해석)

  • Lee, Seung-Pyo;Koh, Byung-Kab;Ha, Sung-Kyu
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.2
    • /
    • pp.123-129
    • /
    • 2009
  • Magnetron is a compartment of microwave oven and it generates the microwave. In this paper, the program HUSAP is developed in order to perform the heat transfer, structure, and fatigue analysis of magnetron. By using it we can make the geometry of magnetron and can solve the governing equations which are formulated by finite element technique. In order to achieve the reliability of HUSAP, we compare it with experiment and commercial software ANSYS. And comparisons of observed results show that agreement is remarkably consistent.

The Fixation Effects of Biological specimen Using Microwave Oven Equipped With Infrared-Temperature Sensor (적외선 온도감응기를 장착한 마이크로파 오븐의 생체물질 고정효과)

  • 신길상
    • The Korean Journal of Zoology
    • /
    • v.37 no.2
    • /
    • pp.144-155
    • /
    • 1994
  • 마이크로파 에너지로서 현미경 관찰을 위한 생체물질을 고정할 때, 고정효과는 화학 고정액을 사용할 때와 비교하여 보다 우수한 또는 적어도 동일한 고정효과를 볼 수 있다는 것은 알려진 사실이다. 그러나 기존의 마이크로파 오븐을 사용하여 생체물질을 고정하면 고정 정도에 일정성이 없는데, 이는 마이크로파가 균일하게 조사되지 않고 고정에 적절하도록 마이크로팍의 강도를 조절하기 어려우며, 이로 인하여 정확한 고정온도의 측정이 불가능하기 때문으로 생각된다. 이 연구에서는 마이크로파가 조사되는 동안 시료의 온도를 측정할 수 없는 기존의 마이크연.파 오븐의 단점을 보완하기 위하여 비접촉식 적외선 온도 감응기를 장착한 마이크로파 오븐을 개발하였으며 고정효과를 관찰하기 위하여는 포유류의 기준 조직으로 알려진 생쥐의 신장을 고정하였다 고정효과는 전체적인 구조와 세부 구조의 보존이 모두 우수하였고 최적의 고정온도는 28$\pm$1$^{\circ}C$(완충용액 20 ml, 10초) 이었다. 이와같이 고정된 재료는 고정효과 뿐만 아니라 염색성이 좋아서 조직화학 반응이 우수하고, 냉동절편법과 연계했을 때 전체 절편제작 과정이 2~4시간 내에 완료될 수 있었다 이때 절편의 질(질)은 화학 고정액이나 냉동절편 법에 의하여 제작된 것 보다 우수하였다.

  • PDF

An Implementation for Effective Shielding System of Information Electronic Equipments (정보가전기기의 효과적인 차폐시스템 구현)

  • Kim, Jae-Yee;Jeong, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2031-2033
    • /
    • 2004
  • In this paper, electromagnetic wave environment generated from electronic equipments was investigated. Since the main source of electromagnetic waves are electronic equipments, the field intensity of a harmful electromagnetic wave was measured and its harmful level was analyzed. It was also found that the result was 23%${\sim}$38% in case of TV set and microwave oven. Based on this analysis, this study proposed efficient shielding method to suppress unwanted electromagnetic wave.

  • PDF

A study on the network schemes of the home appliance using the CEBus (표준 CEBus를 사용한 가전기기의 제어 방식에 관한 연구)

  • 송원국;이연천;김명식;김용득
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.327-331
    • /
    • 1991
  • This paper deals with the network schemes of the home appliance using the CEBus. Protocol schemes which are based on the OSI 7-layer and CAL application were described. And also it was adapted for microwave oven as case study. As a result, it is shown that it operates well under CEBus protocol with only power line media.

  • PDF

Design and Implementation of PLC Home Network System using HNCP ver.1.0 (HNCP ver.1.0에 기반한 전력선 홈 네트워크 시스템의 설계 및 구현)

  • 이감록;이재민;명관주;전요셉;권욱현;정문종
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.179-182
    • /
    • 2003
  • This paper describes the design and implementation of PLC home network system using HNCP ver.1.0. The developed home network system comprises a home server progranL a home master, and appliance emulators (e.g., for washing machine, microwave oven, and air-conditioner). Throughout the implementation of PLC home network system, the feasibility of HNCP ver.1.0 is verified.

  • PDF

Performance of'Bluetooth using Adaptive Frequency Hopping (적응형 주파수호핑을 사용하는 블루투스의 성능)

  • 이승범;박신종
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.137-140
    • /
    • 2002
  • 2.4Ghz ISM 대역에서 동작하는 Bluetooth는 동일한 대역에서 동작하는 WLAN(802.11.b), Cordless phone, microwave oven등의 신호가 interference로 작용하여, 성능이 크게 저하된다. 특히 Bluetooth과 WLAN은 상호간 interference로 작용하여 상호 성능 저하를 초래한다. 따라서, 두 장치간의 coexistence를 위한 방안으로 adaptive hopping frequency(AFH)이 제안되었다. 이 논문에서는 3 channel status를 이용한 AFH 방식을 제안하고, 그 성능을 검증하였다.

  • PDF

Toothbrush sterilizing effects of using microwave (Microwave를 이용한 칫솔 살균효과)

  • Ji, Yun-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.641-646
    • /
    • 2012
  • Objectives : The purpose of this study is to analyze the sterilizing effects of toothbrushes by administering bacteria into toothbrushes and reproducing the antibacterial effects using a microwave oven. Methods : The heads of four-row mid-strength toothbrushes were cut, put in a bacterial solution ($3{\times}10^9cells/ml$) for vortexing, and sterilized with microwaves for 0, 30, and 60 seconds. They were then moved into four tubes containing DW 10 ml and suspended in a vortex mixer for two minutes to separate bacteria from them. DW 9ml was added by 1ml of bacteria for dilution of $10{\sim}10^6$ times. It was then administered to the BHI agar plate by 0.1ml and cultured at $37^{\circ}C$ for 24 hours. Total number of bacteria adhered to a toothbrush was obtained by multiplying the number of colonies by the dilution factor. The experiment was done in the first, second, and third step, being repeated in a normal temperature drier ($23^{\circ}C$) after 5, 9 and 24 hours. Results : The results of the experiment revealed that the sterilizing effects were 95% or over. When toothbrushes were sterilized for 60 seconds, the number of colonies is about 11 after drying for 5 hours, 7 after drying for 9 hours and 2 after drying for 24 hours. The sterilizing effects reached 98% when the bacteria-administered toothbrush was sterilized for 1 minute after drying for 24 hours. Conclusions : The results demonstrated that toothbrush sterilizing by using microwave is a suitable way to prevent cross-contamination of toothbrushes by oral bacterial infection and thus easy to use at home. However, this study suggests that toothbrush sterilizing by using microwave should be limited within two times a week because the physical properties of toothbrush might be changed.

Analysis on Damage Patterns of a Folder Type Mobile Phone Caused by Microwave-irradiation (극초단파 조사에 따른 폴더형 휴대전화 손상 형태 분석)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Kim, Jin-Pyo;Choi, Don-Mook;Oh, Bu-Yeol
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.11-16
    • /
    • 2012
  • In this paper, we analyzed damage patterns of a folder type mobile phone caused by microwave-irradiation, to find an accurate fire cause and to investigate deliberate broken of mobile phone for obtaining pecuniary advantage by deception. In order to analyze broken patterns, we irradiated a mobile phone with microwave using by 2.45 GHz microwave oven. Form the experiment results, damage patterns of mobile phone have been tendency toward heavy broken patterns depending on time of microwave-irradiated. Distinctively, folder hinge and intenna(Planar Inverted-F Antenna) were heavy broken in compare with battery, enclosure and so on. The enclosure of mobile phone became just thermo-metamorphism and the battery was not broken such as explosion.

Microwave Assisted Reaction of Condensed Thiophenes With Electron Poor Olefins

  • Al-zaydi, Khadijah M.;Elnagdi , Mohamed H.
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.591-596
    • /
    • 2003
  • Aminothienopyridazines 1a, b and aminothienocoumarin 2 condensed with DMFDMA to yield amidines 3a, b and 4. These compounds reacted with N-phenylmaleimide to yield 9 and 10. On the other hand reacting 3a, b, 4, 18, 19 and 20 with maleic anhydride afforded only the formylated derivatives 5a, b, 6, 21, 22 and 23 respectively. The reaction of 3a, b with diethyl fumarate afforded 11, formed most likely via hydrolysis of the amidine 14 during working up the reaction mixture. Irradiation of N-phenylmaleimide in microwave oven afforded [2+2] and [2+2+2] cycloaddition product.