• Title/Summary/Keyword: microscopy (electron, scanning)

Search Result 5,022, Processing Time 0.032 seconds

Microstructure and Fracture Path of Cr-Mn-N Steel upon Aging Treatment

  • Lee, Se-Jong;Sung, Jang-Hyun;Ralls, K.M.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.4 no.3
    • /
    • pp.21-30
    • /
    • 1991
  • Microstructural analysis was conducted to observe the effect of aging treatments in a Cr-Mn austenitic stainless steel containing nitrogen, and the amount, size, shape and distribution of precipitates were investigated. It was found that on water quenching from $1000^{\circ}C$ after holding 3 h at that temperature, the steel contained no precipitates observable by optical microscopy. Precipitation of phases begins at places most favorable for the formation of nuclei-in the boundaries of grains and twins. Precipitates were studied in detail by means of scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Chemical compositions of precipitates were examined by the use of scanning transmission electron microscopy (STEM) together with an energy dispersive X-ray (EDX) microanalysis. Also chromium depletion adjacent to grain boundary precipitates was investigated by the use of Auger electron spectroscopy (AES) for a direct examination of the fracture surface chemistry.

  • PDF

Quantitative Evaluation of Dislocation Density in Epitaxial GaAs Layer on Si Using Transmission Electron Microscopy

  • Kim, Kangsik;Lee, Jongyoung;Kim, Hyojin;Lee, Zonghoon
    • Applied Microscopy
    • /
    • v.44 no.2
    • /
    • pp.74-78
    • /
    • 2014
  • Dislocation density and distribution in epitaxial GaAs layer on Si are evaluated quantitatively and effectively using image processing of transmission electron microscopy image. In order to evaluate dislocation density and distribution, three methods are introduced based on line-intercept, line-length measurement and our coding with line-scanning method. Our coding method based on line-scanning is used to detect the dislocations line-by-line effectively by sweeping a thin line with the width of one pixel. The proposed method has advances in the evaluation of dislocation density and distribution. Dislocations can be detected automatically and continuously by a sweeping line in the code. Variation of dislocation density in epitaxial GaAs films can be precisely analyzed along the growth direction on the film.

Scanning Electron Microscopy Studies of Saccharomyces cerevisiae Structural Changes by High Hydrostatic Pressure Treatment

  • Bang, Woo-Suk;Swanson, Barry G.
    • Food Science and Biotechnology
    • /
    • v.17 no.5
    • /
    • pp.1102-1105
    • /
    • 2008
  • The structural change and leakage of cellular substances of Saccharomyces cerevisiae attributed by high hydrostatic pressure (HHP) treatment were observed with scanning electron microscopy (SEM). S. cerevisiae (ATCC16664) was inoculated in apple juice for 10 min at $23^{\circ}C$ and the apple juice treated at 138, 207, 276, 345, and 414 MPa pressure for 30 sec at $23^{\circ}C$. Increased of roughness, elongation, wrinkling, and pores on yeast cell surfaces, the yeast cell walls were severely damaged by HHP treatment from 276 to 414 MPa. Inactivation of S. cerevisiae by HHP is dependent on structural changes on the cell walls observed with SEM.

Scanning Electron Microscopy of the Tisues of Helicoverpa assulta Larvae intoxicated with Bacillus thuringiensis Protein Crystals.

  • Cheon Hyang Mi;You
    • Journal of Sericultural and Entomological Science
    • /
    • v.36 no.2
    • /
    • pp.162-167
    • /
    • 1994
  • Surface changes of tissues caused by B. thuringiensis var. kurstaki-$\delta$-endotoxin intoxication of Helicoverpa assulta were observed by scanning electron microscopy. Bt-endotoxin crystals induced the erosion and disruption on the surface of all tissues tested. The results revealed that the toxin binds to all exposed plasma membranes without apparent specificity for particular membrane domains.

  • PDF

Measurement of 2-Dimensional Dopant Profiles by Electron Holography and Scanning Capacitance Microscopy Methods (일렉트론홀로그래피와 주사정전용량현미경 기술을 이용한 2차원 도펀트 프로파일의 측정)

  • Park, Kyoung-Woo;Shaislamov, Ulugbek;Hyun, Moon Seop;Yoo, Jung Ho;Yang, Jun-Mo;Yoon, Soon-Gil
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.5
    • /
    • pp.311-315
    • /
    • 2009
  • 2-dimensional (2D) dopant profiling in semiconductor device was carried out by electron holography and scanning capacitance microscopy methods with the same multi-layered p-n junction sample. The dopant profiles obtained from two methods are in good agreement with each other. It demonstrates that reliability of dopant profile measurement can be increased through precise comparison of 2D profiles obtained from various techniques.

Replacing critical point drying with a low-cost chemical drying provides comparable surface image quality of glandular trichomes from leaves of Millingtonia hortensis L. f. in scanning electron micrograph

  • Raktim Bhattacharya;Sulagna Saha;Olga Kostina;Lyudmila Muravnik;Adinpunya Mitra
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.15.1-15.6
    • /
    • 2020
  • Sample preparation including dehydration and drying of samples is the most intricate part of scanning electron microscopy. Most current sample preparation protocols use critical-point drying with liquid carbon dioxide. Very few studies have reported samples that were dried using chemical reagents. In this study, we used hexamethyldisilazane, a chemical drying reagent, to prepare plant samples. As glandular trichomes are among the most fragile and sensitive surface structures found on plants, we used Millingtonia hortensis leaf samples as our study materials because they contain abundant glandular trichomes. The results obtained using this new method are identical to those produced via critical-point drying.

Free-standing graphene intercalated nanosheets on Si(111)

  • Pham, Trung T.;Sporken, Robert
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.297-308
    • /
    • 2017
  • By using electron beam evaporation under appropriate conditions, we obtained graphene intercalated sheets on Si(111) with an average crystallite size less than 11nm. The formation of such nanocrystalline graphene was found as a time-dependent function of carbon deposition at a substrate temperature of $1000^{\circ}C$. The structural and electronic properties as well as the surface morphology of such produced materials have been confirmed by reflection high energy electron diffraction, Auger electron spectroscopy, X-ray photoemission spectroscopy, Raman spectroscopy, scanning electron microscopy, atomic force microscopy and scanning tunneling microscopy.

Characteristics of the Infection of Tilletia laevis Kuhn (syn. Tilletia foetida (Wallr.) Liro.) in Compatible Wheat

  • Ren, Zhaoyu;Zhang, Wei;Wang, Mengke;Gao, Haifeng;Shen, Huimin;Wang, Chunping;Liu, Taiguo;Chen, Wanquan;Gao, Li
    • The Plant Pathology Journal
    • /
    • v.37 no.5
    • /
    • pp.437-445
    • /
    • 2021
  • Tilletia laevis Kuhn (syn. Tilletia foetida (Wallr.) Liro.) causes wheat common bunt, which is one of the most devastating plant diseases in the world. Common bunt can result in a reduction of 80% or even a total loss of wheat production. In this study, the characteristics of T. laevis infection in compatible wheat plants were defined based on the combination of scanning electron microscopy, transmission electron microscopy and laser scanning confocal microscopy. We found T. laevis could lead to the abnormal growth of wheat tissues and cells, such as leakage of chloroplasts, deformities, disordered arrangements of mesophyll cells and also thickening of the cell wall of mesophyll cells in leaf tissue. What's more, T. laevis teliospores were found in the roots, stems, flag leaves, and glumes of infected wheat plants instead of just in the ovaries, as previously reported. The abnormal characteristics caused by T. laevis may be used for early detection of this pathogen instead of molecular markers in addition to providing theoretical insights into T. laevis and wheat interactions for breeding of common bunt resistance.

Atomic Resolution Scanning Transmission Electron Microscopy of Two-Dimensional Layered Transition Metal Dichalcogenides

  • Lu, Ning;Wang, Jinguo;Oviedo, uan Pablo;Lian, Guoda;Kim, Moon Jea
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.225-229
    • /
    • 2015
  • Transition metal dichalcogenides (TMDs) are a class of two-dimensional (2D) materials that have attracted growing interest because of their promising applications. The properties of TMDs strongly depend on the crystalline structure and the number and stacking sequence of layers in their crystals and thin films. Though electrical, mechanical, and magnetic studies of 2D materials are being conducted, there is an evident lack of direct atom-by-atom visualization, limiting insight on these highly exciting material systems. Herein, we present our recent studies on the characterization of 2D layered materials by means of aberration corrected scanning transmission electron microscopy (STEM), in particular via high angle annular dark field (HAADF) imaging. We have identified the atomic arrangements and defects in 2H stacked TMDs, 1T stacked TMDs, distorted 1T stacked TMDs, and vertically integrated heterojunctions of 2D TMDs crystals.

Scanning Electron Microscopic Observation on Early Vascular Lesion in Rat Lung Administered with Monocrotaline (Monocrotaline을 투여한 백서 폐의 초기 혈관병변에 관한 주사전자현미경적 관찰)

  • Park, In-Ae;Ham, Eui-Keun
    • Applied Microscopy
    • /
    • v.21 no.1
    • /
    • pp.86-107
    • /
    • 1991
  • An experimental study was performed to observe the early effects of monocrotaline on pulmonary vascular system by means of light microscopy and scanning electron microscopy, attempting to expore the mechanism behind the process of pulmonary hypertension. Experimental animal(Sprague-Dawley male rats ; 150-200g B. W.) were intra-peritoneal administered with 100mg/kg B. W. monocrotaline. Authors observed light microscopically various gradational increase of wall thickness in pulmonary muscular and non-muscular arteries in duration from 2 weeks to 5 weeks after monocrotaline administration and the changes were more sever in the latter than the former. The scanning electron microscopy shows severe and diffuse endothelical cell swelling, microvilli and microbleb formation since 1 hour after monocrotaline administration and during the course, after 5 hours the severity of endothelial cell damage was prominent with presence of fibrin, webs, platelet thrombi and white cell adherence. It was concluded that the monocrotaline primarily induced severe and diffuse endothelial cell damage of pulmonary arteries and laterly added the participation of platelets, which attributed to the pathogenesis of monocrotaline induced pulmonary vascular lesions in relation to pulmonary hypertension.

  • PDF