• Title/Summary/Keyword: microleakge

Search Result 5, Processing Time 0.017 seconds

Gas Tank Microleakage Reception Characteristics According to Thickness of the First Matching Layer of Ultrasonic Sensor (초음파 센서의 1차 정합층 두께에 따른 가스탱크 미세누설 수신특성)

  • Seo, Wonjun;Son, Seongjin;Im, Seokyeon
    • Tribology and Lubricants
    • /
    • v.37 no.5
    • /
    • pp.164-171
    • /
    • 2021
  • Ultrasonic sensors show various reception characteristics based on the density of the measurement medium; hence, they are used in various fields to benefit from the characteristics of ultrasonic signals. In this study, the reception characteristics according to the thickness of the first matching layer are compared and analyzed for application to gas tank microleak detection. Accordingly, three types of sensors are manufactured with varying thicknesses of the first matching layer, namely 4.8 mm, 5.1 mm, and 5.5 mm; further, a direct measurement method is used wherein the sensor is attached to the inside of the chamber. Experiments are conducted to observe the phase change due to microleakage, which is the most linear in the sensor with the 4.8 mm thick first matching layer. This is assumed to be the result of stable signal transmission and reception with little phase deviations over time because the first matching layer is closest to the ultrasonic wavelength. The other sensors show nonlinear results with increasing thickness of the first matching layer. Through this study, it is found that appropriately selecting the thickness of the first matching layer of the ultrasonic sensor can greatly influence sensor reliability.

THE EFFECTS OF PHOTOPOLYMERIZATION OF ADHESIVE ON SHEAR BOND STRENGTH AND MICROLEAKAGE OF FLOWABLE RESIN RESTORATION (유동성 레진 수복술에서 접착제 중합 여부에 따른 미세누출과 전단결합강도에 관한 연구)

  • Park, Yong-Kyu;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.398-407
    • /
    • 2007
  • This study was performed to evaluate possibility to reduce treatment time for child patient who have limited control activity during flowable composite resin restoration according to comparing microleakage and shear bond strength. Group I, II with Single $Bond^{TM}$, group III, IV with AQ Bond $Plus^{TM}$, group V, VI with Prompt L-$Pop^{TM}$, and group VII as control group without adhesive system. 12 premolars and 10 molars were assigned into each group. Restorative material was used the Filtek $Z350^{TM}$ flowable. The results were as follows; 1. The result of microleakage evaluation, in the group I, II with Single $Bond^{TM}$ showed low dye penetration score. Dye penetration between group I and group II were similar. 2. Results for shear bond strength at group I and group II showed values higher than other groups. (p<0.05) There were no statistical differences between group I and group II. (p>0.05) 3. There was no statistical differences among I and II, III and IV, V and VI groups. 4. Group VII showed significantly low shear bond strength than group I, II, V, VI(p<0.05). Group VII showed low value than group with III and IV, but no statistical significances. In conclusion, adhesive bonding resin was not affect significantly to microleakage and shear bond strength of flowable resin restoration. Therefore, to reduce the operation time, adhesive bonding resin and flowable composite resin can be cured at once. But contamination of saliva, location of cavities can affect to bond strength in clinical field.

  • PDF

Evaluation of Marginal and Internal Integrity of Modified Resin-Bonded Fixed Partial Dentures: An In Vitro Study

  • Ahn, Sung-Hyeon;Choi, Jae-Won;Jeon, Yong-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the microleakage of various types of resin-bonded fixed partial dentures (RBFPDs) after artificial aging. Materials and Methods: Forty models with missing first molar were fabricated using artificial resin teeth and were divided into four groups: Group A, conventional RBFPDs design; Group B, modified RBFPDs design; Group C, assembled 3-piece RBFPDs design; and Group D, assembled 3-piece RBFPDs with different occlusal rest positions. Half of the specimens underwent chewing simulation process (240,000 cycles, 50 N load, 1.7 Hz) and thermocycling (temperatures $5^{\circ}C{\sim}55^{\circ}C$, dwelling time 30 seconds) and the remaining 20 specimens didn't receive any treatment. All the specimens were immersed in 2% methylene blue solution for 24 hours to evaluate microleakage, and were sectioned at the middle part of abutment teeth. To evaluate the microleaskage, a dye penetration was calculated. Result: With artificial aging, cyclic loading and thermocycling, a 3-piece RBPFD and a 2-piece RBPFD using original tooth undercuts have significantly lower microleakge (P<0.05) compared to the conventional design of RBPFD and modified RBPFD. Conclusion: Within the limit of this experiment, the assembled RBFPDs exhibited a smaller microleakage than the conventional RBFPDs, implying that the assembled RBFPDs can be more effective for reducing the dislodgement of the RBFPDs.

MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES (상아질 접착제의 미세누출과 변연부 혼화층)

  • Cho, Young-Gon;Kim, Young-Kwan;Ahn, Jong-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

THE EFFECT OF MARGINAL MICROLEAKGE ACCORDING TO THICKNESS OF FLOWBLE RESIN (유동성 레진의 두께가 미세누출에 미치는 영향)

  • Song, Gi-Gang;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.363-371
    • /
    • 2005
  • This study investigated the effect of thickness of flowable resin lining on marginal leakage in class II composite restorations. 80 experimental teeth were prepared with class II preparations with enamel margin or dentin margin. Each group was devided into four groups according to flowable resin lining thickness ; Control group - no flowable resin lining, Group 1 - 0.5 mm flowable resin lining, Group 2 - 1 mm flowable resin lining, Group 3 - 2 mm flowable resin lining. The cavities were restored using Scotchbond Multi-Purpose adhesive system, Filtek Flow and Filtek Z 250 composite resin. Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles and immersed in $2\%$ methylene blue for 24 hours. The results of this study were as follows : 1. Ranking of mean microleakage scores at the enamel margins was Group 1 < Control = Group 2 < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 and Group 2 (p < 0.05). 2. Ranking of mean microleakage scores at the dentin margins was Group 1 < Group 2 < Control < Group 3. The microleakage of Group 3 was significantly higher than that of Control, Group 1 (p < 0.05) 3. Compared with microleakage between the enamel and dentin margins, enamel margin group were significantly lower than dentin margin group.