• 제목/요약/키워드: microcurrent

검색결과 62건 처리시간 0.031초

통증유발 백서에서 미세전류자극이 척수 분절 내 c-fos 및 CGRP 발현에 미치는 영향 (Effects of Microcurrent Stimulation on c-fos and Calcitonin Gene-Related Peptide Expression in the Spinal Cord on Rats Induced Pain)

  • 김계엽;정현우
    • 동의생리병리학회지
    • /
    • 제19권1호
    • /
    • pp.75-80
    • /
    • 2005
  • The purpose of study is that we will observe the change of c-fos and CGRP with the immunohistochemistry method and then we will study the effect of microcurrent stimulation following the frequency after inducing pain to rats with capsaicin. The experimental groups were divided by microcurrent application and pain induce. Normal control groups is used in experiment I, the group which we induce pain is used in experiment II, the application group which we induce pain and then the high frequency microcurrent stimulation is used in experiment III, the application group which we induce pain and then the low frequency microcurrent stimulation is used in experiment IV. c-fos was strongly expressed after pain induced 2 hours and positive neurons were decreased from 2 hours. At 7 days, positive neuron recovers to normal range, But c-fos positive neuron of microcurrent stimulation group were decreased from 2 hours. CGRP was strongly expressed after pain induced 24 hours, and positive neurons were decreased from 7 days. These results suggests that microcurrent stimulation therapy effect to control pain according to expression of c-fos and CGRP examined by immunohistochemistry. Also high frequency microcurrent stimulation is more effective than low frequency microcurrent stimulation for controling the pain.

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • 제2권1호
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

Effect of Graston Technique on Fatigue Recovery after High-Intensity Exercise of the Quadriceps Femoris

  • Son, Ho-Hee
    • 대한물리의학회지
    • /
    • 제13권4호
    • /
    • pp.9-17
    • /
    • 2018
  • PURPOSE: This study was conducted to compare the effects of the Graston-based massage method and microcurrent application on muscle fatigue after causing muscle fatigue of the quadriceps femoris by applying high-intensity exercise. METHODS: Study subjects (56 healthy subjects in their 20s) were randomized into a microcurrent group (MG), Graston group (GG), and control group (CG). To induce fatigue of the quadriceps femoris, the subjects performed squats 100 times without a break within about 5 minutes. Muscle fatigue was measured immediately after performing squats and 15 minutes after intervention. To measure muscle fatigue, surface electromyogram (EMG) was used to obtain and compare the median frequency. Microcurrent or Graston massage was applied to their quadriceps muscles 15 minutes after performing the squats. RESULTS: Muscle fatigue increased significantly in the vastus lateralis before and after intervention in the Graston group (p<.05), while no significant difference was observed in the rectus femoris and vastus medialis (p>.05). There were also no significant differences in the microcurrent group or the control group. CONCLUSION: Both the microcurrent group and Graston group showed a tendency for increasing median frequency values compared to the control group, but there was no significant difference except in the vastus lateralis treated with the Graston technique. Although there was no significant difference, the Graston technique could be utilized to reduce the occurrence of DOMS by preventing muscle fatigue in clinical practice or sports medicine.

The Effect of Microcurrent Stimulation on Pain and Quality of Life in Women with Primary Dysmenorrhea

  • Minkyoung Kwon;Wonjae Choi
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권3호
    • /
    • pp.293-299
    • /
    • 2023
  • Objective: This study aimed to investigate the potential benefits of microcurrent stimulation as a non-invasive therapeutic approach for managing pain and improving the quality of life in women suffering from primary dysmenorrhea. Design: A case study. Methods: This study was conducted, involving a cohort of 6 women diagnosed with primary dysmenorrhea, aged between 20 to 30 years. Participants were received microcurrent stimulation using low-intensity microcurrents for 30 minutes every day for 4 weeks. The intensity of microcurrent stimulation was 25 μA and the frequency was 8 Hz. The intervention was administered between the menstruations, with pain intensity and quality of life being assessed at baseline, and then at the end of menstrual cycle. Pain intensity was evaluated using a visual analog scale (VAS) and menstrual symptom questionnaire (MSQ), while the quality of life was assessed through the stress response inventory (SRI), state trait anxiety inventory (STAI), center for epidemiologic studies depression (CES-D), and menstrual distress questionnaire (MEDI-Q). Results: After the intervention, participants demonstrated a statistically significant reduction in pain intensity, as evidenced by improved VAS scores (p<0.05). However, the changes in MSQ scores did not reach statistical significance. Regarding quality of life measures, no statistically significant differences were found in the SRI, STAI, CES-D, and MEDI-Q scores after the intervention (p>0.05). Conclusions: This study suggest that microcurrent stimulation holds promise as a potential treatment option for alleviating pain associated with primary dysmenorrhea.

미세전류자극과 고전압 맥동직류 통전이 토끼의 비골 골절치유에 미치는 효과 (Effects of Microcurrent and High Voltage Pulsed Galvanic Current Stimulation on Fibular Fracture Healing of the Rabbits)

  • 고승현;윤범철;김지성;민경옥
    • 한국콘텐츠학회논문지
    • /
    • 제11권10호
    • /
    • pp.286-292
    • /
    • 2011
  • 본 연구는 토끼골절모델에 미세전류자극(직류, 음극), 고전압 맥동직류 음극과 양극을 이용해 골절치유정도를 살펴보았다. 방사선 검사에 의한 육안 계측은 미세전류자극군이 고전압 맥동직류의 음극과 양극 통전군보다 골절치유척도 점수에서 통계학적으로 유의한 차이를 보였으나(p<0.05), 고전압 맥동직류 음극군과 양극군 사이에는 유의한 차이가 없었다(p>0.05). Hematoxylin-Eosin 염색과 Masson's trichrome 염색을 통한 병리조직표본 차이는 미세전류자극군에서 무층골의 증식이 다른 두 실험군보다 더 활발하게 관찰되었으며 연골내골화 과정도 다른 두 실험군에 비해 더 빠른 것으로 관찰되었다. Osteocalcin 면역조직화학 염색은 미세전류자극군이 골모세포, 골세포, 파골세포 및 골기질 내에서 면역양성반응이 다른 두 실험군보다 더 명확히 관찰되었다.

미세전류전기자극이 흰쥐의 창상치유에 미치는 영향 (The Effect of Microcurrent Stimulation on Wound Healing in Rat)

  • 오혜진;김정우;박장성
    • 대한임상전기생리학회지
    • /
    • 제6권1호
    • /
    • pp.43-55
    • /
    • 2008
  • The purpose of this study was to investigate the effect of microcurrent stimulation intensity($50{\mu}A,\;100{\mu}A,\;300{\mu}A$ - 5 pps pulse frequency was same) on wound healing in rat. Sixty male Korean rats were randomly divided into 4 groups of 15 for 4 different treatment protocols(none-control group, $50{\mu}A,\;100{\mu}A,\;300{\mu}A$ experimental groups). Experimental 20 mm linear wound were made and all animals in the experimental groups were received microcurrent stimulation once a day for 20 minutes until sacrifice days(1st day, 3rd day, 6th day). A vernier caliper was used to measure a wound healing length and an optical microscope was used to determine any histological changes. The repeated measures two-way ANOVA was used for statistical differences in wound healing length. Experimental results were as follows: 1. In the examination with the naked eye, all groups showed similar changes until 1st day. But from 3rd day, a little intercellular fluid soaked through wound region in control group. In experimental groups, little intercellular fluid soaked through wound region, and swelling and redness did not appear. 2. Wound length of experimental $50{\mu}A$ group was significantly decreased than control group(p<0.001). And in the aspect of application period, wound length was significantly decreased in 3th, 6th day than 1st day and 6th day than 3th day (p<0.001). In conclusion, it has been found that the microcurrent stimulation had a positive effect on wound healing. And $50{\mu}A$ stimulation intensity was more effective than other intensities($100{\mu}A,\;300{\mu}A$) in wound healing. Also, low-intensity microcurrent stimulation was more effective on the purpose of wound healing.

  • PDF

염증유발 백서에서 전침자극과 미세전류자극의 항-통각과민 효과 (Anti-hyperalgesic Effects of Electroacupuncture Combination of Microcurrent Stimulation in Rat with Induced Inflammation)

  • 김영필;이정우;서삼기;윤세원;윤희종;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제19권1호
    • /
    • pp.67-78
    • /
    • 2007
  • Purpose: The purpose of this study were to examine the anti-hyperalgesic effects of combination of electroacupuncture and microcurrent on anti-hyperalgesia in local hyperalgesia zone. Methods: It used 24 rats for experiment, divided them into control group, electroacupuncture group (EA group), microcurrent group (MC group), combination of electroacupuncture with microcurrent (EA+MC group), caused hyperalgesia by injecting ${\lambda}-carrageenan$ into hindpaw. Thickness of hindpaw, mechanical pain threshold (MPT), thermal pain threshold (TPT), noxious flexion withdrawal reflex (NFR) and somatosensory evoked potential (SEP) were measured immediately after induction, at 24 hours, 48 hours and 72 hours after induction. The electrical stimulation was given once a day for three days, 20min per session. Results: Change of thickness, MPT, and TPT showed significant difference in all groups compared to control group. In particular, there were remarkable difference in EA+ME group. In particular there were remarkable differences in EA group and EA+MC group. Change of NFR(% threshold, % reaction time, % RMS) and SEP showed mainly significant differences in EA group and EA+ME group compared to control group. In particular, there were remarkable difference in EA+ME group. Conclusion: The above results suggest that appropriate combination of microcurrent with electroacupuncture for pain control will be very desirable.

  • PDF

미세전류치료가 류마티스 관절염 유발 흰쥐의 Interleukin-1 발현에 미치는 영향 (Influence of Microcurrent Therapy in Interleukin-1 Expression in Rhueumatoid Arthritis Rats)

  • 이현민;채윤원
    • The Journal of Korean Physical Therapy
    • /
    • 제21권2호
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: Electrical stimulation is one of several treatments recommended for RA patients. Electrical stimulation of RA patients, reduces pain, or facilitates joint motion prior to exercises. However, there is still limited evidence on the efficacy of electrical stimulation and thus any conclusions drawn about this method remain controversial. Recently, Microcurrent Electrical Neuromuscular Stimulation (MENS) has received significant attention as a potential method of electrical stimulation. In this study, we investigated the effect of microcurrent treatment in rheumatoid arthritis rat. Methods: Subjects were allocated either to the control group or experimental group, which was subject to microcurrent stimulation. Interleukin-1 expression in the metatarsophlangeal joint and the oedema index in the ankle were used for classification and subsequent evaluation of pathology. Subjects were assessed at 1, 7 and 14 days after inducing rheumatoid arthritis through adjuvant injection. Thirty-six subjects, 18 in each group, were used in this study. Statistical analysis was performed by calculating the differences between the two groups and between each interval assessment. Categorical variables were compared between the two groups with the paired-T test. The one-way ANOVA test was performed to assess changes in ordinal variables. Results: Baseline characteristics were similar in both groups. Statistically significant differences were found between the two groups. The biological marker of pro-inflammatory cytokine and oedema index were decreased in response to this treatment. Conclusion: These data show that treatment of rheumatoid arthritis with a microcurrent stimulation device reduced the oedema index and pro-inflammatory cytokine IL-1.

  • PDF

미세전류전기자극이 흰쥐 창상의 조직학적 구조에 미치는 영향 (The Effect of Microcurrent Stimulation on Histological Structure of Wound in Rat)

  • 오혜진;김정우;김문수;박장성
    • The Journal of Korean Physical Therapy
    • /
    • 제20권1호
    • /
    • pp.67-73
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the effect of the intensity of microcurrent stimulation (with currents of 50 ${\mu}A$, 100 ${\mu}A$ and 300 ${\mu}A$ using a pulse frequency of 5 pps) on wound healing in rats. Methods: Sixty male Korean rats were randomly divided into four groups of 15 rats that were subjected to four different treatment protocols (control group, no treatment; experimental groups, treated with currents of 50 ${\mu}A$, 100 ${\mu}A$ or 300 ${\mu}A$). An experimental 20 mm linear wound was made in each animal and all animals in the experimental groups received microcurrent stimulation once a day for 20 minutes until the day of sacrifice on day 1, day 3 and day 6. An optical microscope was used to determine any histological changes. Results: The experimental results were as follows. 1. In an examination with the naked eye, all groups showed similar changes until the first day. However, from the third day, a little intercellular fluid soaked through wound region in the control group rats. In the experimental group animals, little intercellular fluid soaked through wound region, and swelling and redness did not appear, from the third day. 2. In an examination with histological evaluation, more significant changes were observed in all of the experimental group rats than the control group animals. Especially, a stimulation intensity of 50 ${\mu}A$ caused a more significant effect than the use of the other intensities by day 6 of wound healing. In addition, rapid recovery was observed. Conclusion: It was determined that microcurrent stimulation had a positive effect on wound healing. A stimulation intensity of 50 ${\mu}A$ was more effective than the other intensities (100 ${\mu}A$ and 300 ${\mu}A$) utilized for wound healing. Furthermore, low-intensity microcurrent stimulation was more effective for the purpose of wound healing.

  • PDF

미세전류 테이핑 치료의 만성 요통에 대한 효과 (Effect of Microcurrent Taping Therapy on Lower Back Pain)

  • 권동현;이상민;김호준;이종수
    • 대한한의학회지
    • /
    • 제32권5호
    • /
    • pp.114-125
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the efficacy of microcurrent taping therapy and kinesio taping therapy. Methods: We included 58 participants who met the inclusion criteria and assigned them into two groups after the randomization. We allocated 29 participants to the microcurrent taping therapy group (MCT) and the other 29 to the general kinesio taping therapy group (GT). 27 participants completed the trial in the MCT group, 27 participants in GT. We attached "I" shaped 20cm tape along the erector muscle of the spine starting from the level of S2, and another 30cm tape on the iliac crest horizontally. These "I" shaped tapes were attached on two parts of the body and were performed the same way for both groups. This procedure was done 8 times and participants visited a total of 9 times including a final visit for evaluation. We measured Visual Analog Scale (VAS), Range of Motion (ROM) and Schober's test on every visit. Participants completed a questionnaire of Oswestry Disability Index (ODI) and Beck's Depression Inventory (BDI) on the first and last visits. Results & Conclusion: There was a significant effect of microcurrent taping therapy on lower back pain, but we could not establish the superior effect of microcurrent taping therapy compared with general kinesio taping therapy.