• 제목/요약/키워드: microcolumn

검색결과 45건 처리시간 0.017초

Simultaneous Quantitative Determination of Monosaccharides Including Fructose in Hydrolysates of Yogurt and Orange Juice Products by Derivatization of Monosaccharides with p-Aminobenzoic Acid Ethyl Ester Followed by HPLC

  • Ko, Joung-Ho;Huang, Huazi;Kang, Gyoung-Won;Cheong, Won-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권10호
    • /
    • pp.1533-1538
    • /
    • 2005
  • We have determined the contents of monosaccharides in the hydrolysates of some yogurt and orange juice products by derivatizing monosaccharides with p-aminobenzoic acid ethyl ester (ABEE). The separation of the ABEE-derivatized monosaccharides was efficiently carried out by HPLC using a microcolumn packed with the Alltima $C_{18}$ stationary phase. The concentrations of monosaccharides were determined based on the measured peak area/height counts. ABEE derivatization of fructose and its detection have never been successfully carried out before this work. In this study, two peaks were observed in a fixed ratio for ABEE-fructose, and the ratio was maintained over a wide range of fructose concentration. In order to prove the validity of the above method, we compared the concentrations of glucose, galactose and fructose determined by ABEE derivatization and UVD (ultraviolet detector) chromatography with those determined by RID (refractive index detector) chromatography without derivatization. The determined concentrations of monosaccharides obtained from the two chromatographic methods were found close to each other within acceptable error ranges.

초소형 전자 렌즈의 전자 광학적 분석 (Electro-optical analysis of a miniaturized electrostatic electron lens)

  • 김호섭;김대욱;김영철;최상국;김대용
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.194-199
    • /
    • 2003
  • FCM(Fast moving least square reproducing kernel point collocation method) 방식의 simulation tool을 이용하여 전기장으로 구동되는 초소형 전자 렌즈의 구동 특성을 조사·분석하였다. Einzel 렌즈의 retarding mode와 accelerating mode구동에서 포텐셜 분포는 유사하지만, electric field strength는 서로 다른 방향을 갖게 되어 서로 다른 형태의 전자 궤적을 보인다. 동일한 working distance에서 accelerating mode로 구동되는 전자렌즈는 retarding mode로 구동되는 경우보다 매우 높은focusing 전압을 필요로 한다.

Aflacxin에 대한 최신 분석법과 규제동향 (Development of Rapid, Safe Analytical Techniques of Aflatoxins and Their Current Regulation)

  • 정덕화
    • 한국식품위생안전성학회지
    • /
    • 제5권3호
    • /
    • pp.131-138
    • /
    • 1990
  • Aflatoxins is a chemically diverse group of toxic secondary metabolites that are produced by fungi and often occur in agricultural commodities. Because of their wide range of toxic effects, Aflatoxins cause severe economic losses to farmers and livestock producers and pose a health to human consuming contaminated foods. Long term prospects for biotechnological control of Aflatoxins require elucidation of the specific steps and regulation of their biosynthetic pathways . Aflatoxin determinations can be approached many ways. It is essential to safely handle all experimental materials associated with aflatoxin analysis or aflatoxigenic fungi Visual screening of suspect samples, base on the presence of conidial head of the aspergillus flavus group, and screening samples for the presence of bright greenish yellow flourescence are not chemical tests and such screening techniques may allow aflactoxin contaminated lots into commerce. Microcolumn screening procedures should always be used in conjunction with a quantitative method. Several thin layer chromatography(TLC) and high performance liquid chromatography(HPLC) methods are suitable for quantitation and are in general use. Immunochemical Methods such as the ELISA or affinity column chromatography methods are being rapidly developed. The chemical and immunochemical methods can be reliable if care is taken, using suitable controls and personnel that are well trained . All analytical laboratories should stress safety and include suitable analytical validation procedure. Especially a worldwide enquiry was undertaken in recent to obtain up-to-date information about aflatoxin legislation in as many countries of the world as possible. The information concerns aflatoxin in foodstuffs. aflatoxin MI in dairy products, aflatoxins in animal feedstuffs. Limits and regulations for aflatoxin have been expended in recent with more countries having legislation on subject, more products, and more aflatoxins covered by this legislation.

  • PDF

ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가 (Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening)

  • 박영춘;임진숙;고영현;권계철;구선회;김지명
    • 대한수혈학회지
    • /
    • 제23권2호
    • /
    • pp.127-135
    • /
    • 2012
  • 배경: 대부분의 임상검사가 자동화되는 추세이나 혈액은행 검사는 여전히 수작업에 의존하고 있다. 여러 자동화장비가 개발되어 활용되고 있으며 최근 면역혈액검사를 위한 자동화장비인 IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA)이 소개되었다. 이번 연구에서는 IH-1000 장비의 ABO 및 Rh 혈액형 검사와 비예기항체 선별검사에 대한 성능을 평가하려고 한다. 방법: 2011년 10월에 의뢰된 373건의 ABO 및 RhD 혈액형 검사와 303건의 비예기항체 선별검사를 대상으로 하였다. ABO 및 RhD 혈액형 검사는 슬라이드법과 시험관법을 사용하였고 비예기항체검사는 미세원주응집법(DiaMed-ID system)을 사용하여 IH-1000의 결과와 비교하였다. 결과: ABO 및 RhD 혈액형 검사에서는 두 방법 간 100%의 높은 일치율을 보였고 비예기항체 선별검사에서는 두 방법에서 모두 양성을 보인 검체가 10건(anti-E+c 4건, anti-E 3건, anti-D 1건, anti-M 1건, anti-Xg 1건)이었고 모두 음성을 보인 검체는 289건으로 98.7%의 일치율을 보였다. IH-1000의 민감도 및 특이도는 각각 90.9%였다. 결론: IH-1000은 기존에 사용하던 수기법과 비교하여 ABO 및 Rh 혈액형 검사와 비예기항체 선별검사에서 높은 일치도를 보였다. 따라서 혈액은행에서의 수혈 전 일상검사에 자동화 장비인 IH-1000을 사용할 수 있을 것으로 생각된다.

중화반응으로 증명된 Anti-Sda 1예 (A Case of Anti-Sda Proven by Urine Neutralization Test)

  • 윤승규;김장수;양진혁;윤수영;이창규;임채승;조윤정;김영기;이갑노
    • Laboratory Medicine Online
    • /
    • 제1권1호
    • /
    • pp.64-66
    • /
    • 2011
  • 항-Sda는 용혈성 수혈 부작용 발생이 적은 항체이므로, 항체 선별검사에서 의심이 되어도, 항체 동정이 보통은 생략된다. 저자들은 73세 남자 환자에서 수혈 전 비예기 항체 검사에서 혼합시야 반응을 보이면서 항체 동정검사에서 확인되지 않는 항체를 확인하였다. 항-Sda 의심하에 추가적인 소변 중화반응으로 동정하였다. 비록 항-Sda는 임상적 중요성이 떨어지지만, 고빈도 항원에 대한 항체이기 때문에 교차시험 검사에서 문제가 발생할 수 있다. 항-Sda로 추정되는 경우에는 소변으로 중화된 혈청으로 검사하는 것이 부적합 교차시험에 대한 해결책이 될 수 있다.